RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      검색결과 좁혀 보기

      선택해제
      • 좁혀본 항목 보기순서

        • 원문유무
        • 등재정보
        • 학술지명
        • 주제분류
        • 발행연도
        • 작성언어
        • 저자
          펼치기

      오늘 본 자료

      • 오늘 본 자료가 없습니다.
      더보기
      • 무료
      • 기관 내 무료
      • 유료
      • KCI등재

        Influence of hydrodynamic parameters in plate heat exchangers in ice slurry transport

        Jiménez Pacheco Hugo Guillermo,Milon Guzmán Juan José,Miranda Ramos Lilia Mary,Delgado Sarmiento Pavel Kewin,Linares Flores Castro Antonio Erick,Leal Braga Sergio 대한설비공학회 2023 International Journal of Air-Conditioning and Refr Vol.31 No.1

        Ice slurry is applied in different refrigeration and air conditioning systems, and among its main advantages is the ability to store latent heat and be pumpable as cold water. This fluid can be used for thermal storage instead of cold water or solid ice, since, at certain concentrations, it can be pumped through heat exchangers. For this technology to be widely used, the equipment must be designed considering the heat exchange characteristics. This study developed an experimental system to study the parameters that influence heat exchange, using ice slurry in a plate heat exchanger and water as a thermal load. Several situations with different flows and initial fractions of ice in ice slurry were analyzed. The input conditions of the thermal load were kept constant, the temperature, the pressure drop and the flow of the ice slurry in the heat exchanger were controlled, according to the Nusselt, Prandtl, and Reynolds coefficients. Results show that the global heat exchange coefficient increases with the increase of the initial ice fraction; the cooling capacity of the heat exchanger increases when ice slurry is used as a fluid. For flow rates greater than 0.16 kg/s and ice fractions above 11%, ice crystals are generated at the heat exchanger outlet, due to the ice slurry’s higher viscosity, at approximately 0.003 Pa at the outlet, since the pressure drop increases as the initial ice fraction increases. Results show ice slurry thermohydraulic behavior. Its use shows favorable characteristics in heat exchange. Ice slurry is applied in different refrigeration and air conditioning systems, and among its main advantages is the ability to store latent heat and be pumpable as cold water. This fluid can be used for thermal storage instead of cold water or solid ice, since, at certain concentrations, it can be pumped through heat exchangers. For this technology to be widely used, the equipment must be designed considering the heat exchange characteristics. This study developed an experimental system to study the parameters that influence heat exchange, using ice slurry in a plate heat exchanger and water as a thermal load. Several situations with different flows and initial fractions of ice in ice slurry were analyzed. The input conditions of the thermal load were kept constant, the temperature, the pressure drop and the flow of the ice slurry in the heat exchanger were controlled, according to the Nusselt , Prandtl , and Reynolds coefficients. Results show that the global heat exchange coefficient increases with the increase of the initial ice fraction; the cooling capacity of the heat exchanger increases when ice slurry is used as a fluid. For flow rates greater than 0.16 kg/s and ice fractions above 11%, ice crystals are generated at the heat exchanger outlet, due to the ice slurry’s higher viscosity, at approximately 0.003 Pa at the outlet, since the pressure drop increases as the initial ice fraction increases. Results show ice slurry thermohydraulic behavior. Its use shows favorable characteristics in heat exchange.

      • KCI등재후보

        Slip Clip after successful microsurgery of a blister aneurysm: Should bypass always be the first option?

        Paiva Aline Lariessy Campos,Aguiar Guilherme Brasileiro de,Flores Juan Antonio Castro,Veiga José Carlos Esteves 대한뇌혈관외과학회 2021 Journal of Cerebrovascular and Endovascular Neuros Vol.23 No.3

        Blood Blister-like aneurysms are intracranial non-saccular aneurysms with higher rupture risk due to its fragile wall. Diagnosis is performed in the acute phase of a subarachnoid hemorrhage. There are several treatment options based on reconstructive or deconstructive techniques. This paper aims to discuss the limitations of microsurgery clipping for a ruptured blister aneurysm. We report on a case of a female patient presented with a Fisher III subarachnoid hemorrhage. Cerebral angiography revealed an internal carotid artery blister aneurysm. Initially microsurgery clipping was successfully performed. However, after a few days the patient presented new subarachnoid hemorrhage. The new cerebral angiography showed growth of the previously clipped aneurysm, with displacement of the clip from the position adjacent to the artery. High-flow bypass was performed obtaining definitive treatment. This is a definitive approach for blister aneurysms. If microsurgery clipping is chosen, a strict follow-up is required due to the dynamic nature of this lesion and the chance of re-bleeding even after successfully clipping.

      연관 검색어 추천

      이 검색어로 많이 본 자료

      활용도 높은 자료

      해외이동버튼