RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      검색결과 좁혀 보기

      선택해제
      • 좁혀본 항목 보기순서

        • 원문유무
        • 원문제공처
        • 등재정보
        • 학술지명
        • 주제분류
        • 발행연도
        • 작성언어
        • 저자
          펼치기

      오늘 본 자료

      • 오늘 본 자료가 없습니다.
      더보기
      • 무료
      • 기관 내 무료
      • 유료
      • KCI등재

        Evaluation of the correlation between insertion torque and primary stability of dental implants using a block bone test

        Dorjpalam Bayarchimeg,님궁희,김병국,김명덕,김성태,김태일,설양조,이용무,구영,류인철,이은희,구기태 대한치주과학회 2013 Journal of Periodontal & Implant Science Vol.43 No.1

        Purpose: Implant stability at the time of surgery is crucial for the long-term success of dental implants. Primary stability is considered of paramount importance to achieve osseointegration. The purpose of the present study was to investigate the correlation between the insertion torque and primary stability of dental implants using artificial bone blocks with different bone densities and compositions to mimic different circumstances that are encountered in routine daily clinical settings. Methods: In order to validate the objectives, various sized holes were made in bone blocks with different bone densities (#10,#20, #30, #40, and #50) using a surgical drill and insertion torque together with implant stability quotient (ISQ) values that were measured using the Osstell Mentor. The experimental groups under evaluation were subdivided into 5 subgroups according to the circumstances. Results: In group 1, the mean insertion torque and ISQ values increased as the density of the bone blocks increased. For group 2, the mean insertion torque values decreased as the final drill size expanded, but this was not the case for the ISQ values. The mean insertion torque values in group 3 increased with the thickness of the cortical bone, and the same was true for the ISQ values. For group 4, the mean insertion torque values increased as the cancellous bone density increased, but the correlation with the ISQ values was weak. Finally, in group 5, the mean insertion torque decreased as the final drill size increased,but the correlation with the ISQ value was weak. Conclusions: Within the limitations of the study, it was concluded that primary stability does not simply depend on the insertion torque, but also on the bone quality.

      • SCIESCOPUSKCI등재

        Evaluation of the correlation between insertion torque and primary stability of dental implants using a block bone test

        Bayarchimeg, Dorjpalam,Namgoong, Hee,Kim, Byung Kook,Kim, Myung Duk,Kim, Sungtae,Kim, Tae-Il,Seol, Yang Jo,Lee, Yong Moo,Ku, Young,Rhyu, In-Chul,Lee, Eun Hee,Koo, Ki-Tae Korean Academy of Periodontology 2013 Journal of Periodontal & Implant Science Vol.43 No.1

        Purpose: Implant stability at the time of surgery is crucial for the long-term success of dental implants. Primary stability is considered of paramount importance to achieve osseointegration. The purpose of the present study was to investigate the correlation between the insertion torque and primary stability of dental implants using artificial bone blocks with different bone densities and compositions to mimic different circumstances that are encountered in routine daily clinical settings. Methods: In order to validate the objectives, various sized holes were made in bone blocks with different bone densities (#10, #20, #30, #40, and #50) using a surgical drill and insertion torque together with implant stability quotient (ISQ) values that were measured using the Osstell Mentor. The experimental groups under evaluation were subdivided into 5 subgroups according to the circumstances. Results: In group 1, the mean insertion torque and ISQ values increased as the density of the bone blocks increased. For group 2, the mean insertion torque values decreased as the final drill size expanded, but this was not the case for the ISQ values. The mean insertion torque values in group 3 increased with the thickness of the cortical bone, and the same was true for the ISQ values. For group 4, the mean insertion torque values increased as the cancellous bone density increased, but the correlation with the ISQ values was weak. Finally, in group 5, the mean insertion torque decreased as the final drill size increased, but the correlation with the ISQ value was weak. Conclusions: Within the limitations of the study, it was concluded that primary stability does not simply depend on the insertion torque, but also on the bone quality.

      • KCI등재

        몽골과 한국의 집회시위 관련법 비교 분석

        양문승,Dorjpalam Shagdar 원광대학교 경찰학연구소 2012 경찰학논총 Vol.7 No.2

        최근 10년 사이 베트남, 몽골, 우즈베키스탄 외 독립국가연합 등 아시아의 체제 전환국은 한국의 정부조직 및 경제, 사회, 문화 전 분야에 있어 다각도로 관심을 보이며, 한국 방문 및 연수를 통해 다양한 제도를 접하고자 하는 동향을 보이고 있다. 몽골의 경우 지난 2009년 한국 경찰청 및 형사사법 관련기관을 방문하여 과 학수사 및 경찰제도에 깊은 관심을 보인 바 있다. 몽골 경찰은 1990년대 정치체계 및 경제체제 전환 후 과도기적 민주주의 형태의 국가운영 시기를 겪으며 급속도로 변화되어 왔다. 특히 2008년 발생한 부정선거 관련 집회시위는 이에 대응하는 경찰활동의 중요성을 확인하는 계기가 되었다. 이 연구는 몽골 데모, 시위 및 집합법과 한국의 집회 및 시위에 관한 법률을 비 교 분석하여 향후 몽골의 집회시위에 있어 경찰활동의 방향을 제시하고자 하는 모 적으로 진행되었다. 연구 결과 몽골법의 경우 집회시위 절차의 구체화가 부족하며, 경찰활동의 분야 가 한정되어 있고, 시민안전을 위한 다양한 창구가 부족한 한계가 나타났다. 반면 몽골의 문화와 현실을 반영한 법제를 지니고 있으며, 지방자치단체의 참여가 두드 러졌으며, 집회시위 불가 통보에 대해서는 법원의 개입으로 조정된다는 점이 독창 적이라고 하겠다. 한국법의 경우 집회시위에 있어서 경찰이 중심이 있었으며, 이에 반해 인권보장을 위한 다양한 제도를 도입하고 있었다. 비교분석 후 몽골의 현실을 감안하여 집회신청 절차의 구체화, 경찰의 역할 정립, 민주적인 집회시위 제도적 보완, 몽골의 현실과 전통 문화의 반영에 대해 제언하였다.

      연관 검색어 추천

      이 검색어로 많이 본 자료

      활용도 높은 자료

      해외이동버튼