RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      검색결과 좁혀 보기

      선택해제

      오늘 본 자료

      • 오늘 본 자료가 없습니다.
      더보기
      • 무료
      • 기관 내 무료
      • 유료
      • KCI등재

        Precise performance characterization of perovskite solar cells

        Yoshihiro Hishikawa,Haruya Shimura,Takashi Ueda,Ayumi Sasaki,Yuki Ishii 한국물리학회 2016 Current Applied Physics Vol.16 No.8

        Experimental procedure for precisely characterizing the performance of perovskite solar cells such as the current-voltage (I-V) curves and the maximum output power Pmax is investigated, based on results of the samples with different structures. Special care is taken for the hysteresis effects. Confirming the hysteresis of the I-V curves in a wide range including the timescale of minutes is preferred for precise measurements, since the hysteresis remains for more than 10 min in some samples. When the hysteresis is persistent even for a long sweep time, the stable Pmax can be determined by examining the temporal trend of the output current by fixing the bias voltage at near Vpm after forward and reverse bias histories.

      • KCI등재

        AndComparison of the Chemical Characteristics and Toxicity of PM2.5 Collected Using Different Sizes of Cyclones

        Zikrilla Bobamuratovich Alimov,Hyunwoo Youn,Ayumi Iwata,Kohei Nakano,Takuma Okamoto,Ayaha Sasaki,Takuya Katori,Tomoaki Okuda 한국대기환경학회 2022 Asian Journal of Atmospheric Environment (AJAE) Vol.16 No.3

        Cyclone sampling devices have been helpful in assessing the toxic effects of fine particulate matter (PM2.5). The particle collection efficiency of sampling devices is critical. This study investigated the effect of cyclone size on particle size, chemical composition, and particle toxicity. Three cyclones with different inner diameters (12-68 mm) were tested for penetration using an aerodynamic particle sizer, fluorescent polystyrene latex, and a differential mobility analyzer. The elemental and water-soluble ion compositions of the particles collected by different cyclones were compared. An evaluation of the particles’ toxicity was conducted by comparing the results of dithiothreitol (DTT), limulus amebocyte lysate (LAL), and cell exposure assays. The experimental evaluation showed a 50% cut-size of the cyclones between 0.17-0.28, 0.34-0.36, and 0.70 μm for the small, medium, and large cyclones, respectively. To collect PM2.5 and evaluate separation performance in the real environment, the small and large cyclones were selected according to the particle penetration and flow rate. A comparison of chemical composition and enrichment factor values found that the particles in the small cyclone samples contained smaller and more anthropogenic sources than those in the large cyclone samples. The oxidative potential (OP) measured by the DTT assay of the samples collected using the small and large cyclones differed across sampling periods and associated with the transition metals. The viability of human epithelial A549 cells after exposure to the collected particles using the cyclones was different across sampling periods and associated with OP. The endotoxin concentrations measured in the LAL assay were found only in the large cyclone samples; they affected the estimated level of cytokine based on IL(interleukin)-6 release from human leukemia monocytic (THP-1) cells derived macrophage- like cells. Regardless of the size, the cyclone techniques used in this study to collect aerosol particles would be a powerful tool for a detailed evaluation of particle toxicity.

      연관 검색어 추천

      이 검색어로 많이 본 자료

      활용도 높은 자료

      해외이동버튼