복합혼합날개를 장착한 5×5 봉다발에서 부수로 혼합 및 임계열유속 실험 연구
강경호(K. H. Kang),신창환(C. H. Shin),추연준(Y. J. Choo),윤영중(Y. J. Youn),박종국(J. K. Park),문상기(S. K. Moon),천세영(S. Y. Chun) 대한기계학회 2007 대한기계학회 춘추학술대회 Vol.2007 No.5
Experiments were performed to determine the thermal (or turbulent) diffusion coefficient (TDC) and to investigate the critical heat flux (CHF) performance in the 5×5 rod bundle with 5 unheated rods which are supported by Hybrid Mixing Vane. In this study, HFC-134a fluid was used as working fluid and the fluid temperature were measured in the important subchannels. To determine the TDC value, the measured fluid temperatures were compared with the predicted values obtained from the MATRA code. The best optimized value of β was found to be 0.02 by considering prediction statistics, i.e., average and standard deviations of the differences between the experimental results and code calculations. Using the best optimized value of β as 0.02, the MATRA code predicts the test results of the fluid temperature within ±1.0 % of error. According to the experimental results on CHF of 5 non-heating guide tubes, the case with non-heating guide tube showed a little good performance in terms of CHF.
증기제트 응축으로 유발된 난류제트의 유동특성 예측 상관식 개발
강형석(Hyung Seok Kang),김연식(Y. S. Kim),윤영중(Y. J. Youn),송철화(C. H. Song) 대한기계학회 2008 대한기계학회 춘추학술대회 Vol.2008 No.5
An experimental research was performed to develop an empirical correlation of the turbulent water jet induced by the steam jet through a single hole in a subcooled water pool. A moveable pitot tube including a thermal couple was used to measure a local velocity and temperature of the turbulent water jet. The experimental results show that the velocity and the temperature distributions agree well with the theory of axially symmetric turbulent jet. The correlation predicting the maximum velocity of the turbulent jet was modified from the previous correlation and a new correlation to predict the characteristic length was developed based on the test results.