올바른 RGP 렌즈의 처방과 관리용품의 사용에 대한 결과 연구
성정섭(Jeong Sub Seong),홍수학(Soo Hak Hong) 한국안광학회 2000 한국안광학회지 Vol.5 No.2
We performed refraction, keratometry, slit lamp biomicroscopy. We selected 58 current spherical RGP lens wearers for this three - month study. All patients exhibits at least 0.75D of corneal astigmatism measured with the keratometer, and 37 patients had corneal astigmatism of 1.50D or greater. At least follow - up visit, we measured Snellen acuity with lenses, and performed over refraction, overkeratometry and slit lamp biomicroscopy. We charted lens position, movement and surface quality. During the three month, biomicroscopy revealed no corneal edema and neo vascularization on any patients. Fluorescein staining were 52 patients case of grade 0. 5 patients case of grade 1, and 1 patient case of grade 2. In evaluating post-fit residual cylinder, on over refraction as a percentage of refractive cylinder. By the initial visit, one - week visit, one - month visit, and two - month visit are 41 %, 34%. 29%, respectively. In this data, we knew no change after one month. The average overrefraction for these eyes in absolute diopters is 0.26D ( initial visit ) , 0.22D ( one - week visit. 0.17D ( one - month visit ) , and 0.16D ( two - month visit ) . The use of a regimen containing a dedicated daily cleaner was more effective in maintaining patient comfort and lens cleanliness than was the use of a regimen containing only a multipurpose solution.