다공질 폴리우레탄 폼 매트릭스 축류 회전형 열교환기의 성능특성에 관한 실험적 연구
태춘섭,박상동,조성환,최영돈,Tae, C.S.,Park, S.D.,Cho, S.H.,Choi, Y.D. 대한설비공학회 1993 설비공학 논문집 Vol.5 No.1
This is an experimental study to identify the performance of air-to-air rotary heat exchanger with polyurethane foam matrix. The experimental apparatus including heating AHU(Air Handling Unit), cooling AHU, sensor chamber, and heat exchanger testing unit was designed and manufactured in this study. The performance of heat exchanger with porous polyurethane foam matrix was tested with variations of the density and the thickness of matrix, regulating the wind velocity and the rotational speed of matrix. The actual heat recovery effectiveness, air leakage rate, and pressure drop of heat exchanger were measured and analyzed.
조성환,태춘섭,장철용,Cho, S.H.,Tae, C.S.,Jang, C.Y. 대한설비공학회 1997 설비공학 논문집 Vol.9 No.4
An experimental facility consisting of two $3{\times}4.4{\times}3.8m$ rooms identical in construction is built. Each room has a control system and storage tank supplying hot water to the radiant floor heating system. The facility enables simultaneous comparision of two different control stratigies each implemented in a separate room. The operating performance of three kinds of flow control scheme is tested and compared in this study : (i) conventional on-off control based on feedback from room air temperature (ii) TPSC(two parameter switching control) (iii) TPOC(two parameter on-off control). Results show that TPSC and TPOC using room air and surface temperature sequentially as feedback signal to control hot water supply is the better temperature regulation scheme than conventional control based on feedback from only room air temperature. They are good candidates for the room with radiant floor heating system under continuous and intermittent heating mode.
조성환,태춘섭,Cho, S.H.,Tae, C.S. 대한설비공학회 1996 설비공학 논문집 Vol.8 No.3
By describing the floor slab of a radiant heating system as a one dimensional transient heat exchanger problem, a dynamic analysis model to incorperate with TRNSYS program was developed and their results were compared with experimental results. Results showed that the both of TPOC(Two Parameter On-off Control) and TPSC(Two Parameter Switching Control) method using room air temperature and floor surface temperature as the control parameters does not maintain room air and floor surface temperature exactly at the setting temperatures. But TPSC method is a better candidate for the temperature regulations of room air and floor surface temperature than TPOC method which can keep on the upper and lower limit temperature according to outside temeperature and wall structure etc. And better thermal circumstance can be given by TPSC method than On-off and TPOC method and the overheating which can be occured at the radiant floor heating system with on-off heating control will be reduced.