http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
최국헌,한순흥,Choi, Guk-Heon,Han, Soon-Hung 한국정밀공학회 1995 한국정밀공학회지 Vol.12 No.11
Several non-manifold data structures have been compared, which are radial-edge data structure, partial-face data structure, vertex-based data structure, and Yamaguchi's data structrue. All the entities in the data structures are classified into common entities and special entities. The entities are also classified as model entities, primitive entities bounding entities, and coupling entities. The four data structures for nonmanifold solid modelers are compared in terms of accessing efficiency, storage requirements, and inclusion of circulation. The results of comparison will serve as the basis to develope a nonmanifold modeler.
최국헌 한국공작기계학회 2004 한국공작기계학회 추계학술대회논문집 Vol.2004 No.-
As the increasing needs in the industrial filed, many studies for the 3D CAD system are carried out. There are two types of 3D CAD system. One is manifold modeler, the other is non-manifold modeler. In the manifold modeler only 3D objects can be modeled. In the non-manifold modeler 3D, 2D, ID, and 0D objects can be modeled in a unified data structure. Recently there are many studies on the non-manifold modeler. Most of them are focused on finding unknown topological entities and representing all kinds of topological entities found. In this paper, efficient data structure is selected. The boundary information on a face and an edge is included in this data structure. The boundary information on a vertex is excluded considering the frequency of usage. Because the disk cycle information is not required in most case of modeling. It is compact. It stores essential non-manifold information such as loop cycle and radial cycle. A suitable Euler-Poincare equation is studied and selected. Using the efficient data structure and the selected Euler-Poincare equation, 18 basic Euler operators are implemented. Several 3D models arc created using the implemented modeler. A non-manifold modeling can be carried out using the implemented 3D CAD system. The results of this paper could be used in the further studies such as an implementation of Boolean operators, and a translation of 2D CAD drawings to 3D models.
최국헌,김홍제,이진호 연세대학교 산업기술연구소 1985 논문집 Vol.17 No.1
An experimental investigation was conducted to study the effect of surface roughness on condensation heat transfer characteristics of horizontal circular tube varying the roughness configurations. Eight pin-type finned-tubes were tested using the steam as a condensing substance. Sharp fin-shaped tube shows higher overall heat transfer coefficient, heat transfer rate and tube outside heat transfer coefficient based on the outer surface area of the smooth tube than the blunt one. In addition, the lower the fin height, and the wider the fin pitch, the higher the overall heat transfer coefficient, heat transfer rate and the tube outside-heat transfer coefficient. Globally varying the fin shape and fin pitch showed larger influence on the condensation heat transfer characteristics than the fin height variation.
Effect of Cortisone on Serum Protein of Gamma-Irradiated Mice
조유정,최국헌,남상열,Cho, You Joung,Choi, Kook Hun,Ham, Sang Yul The Korean Society for Integrative Biology 1971 동물학회지 Vol.14 No.3
1. $^{60}Co$의 $\gamma$선 128 rad로 마우스를 전신조사시킨 바 대조군과 cortisone투여군에서 총 혈청단백량은 1일구에서 A/G비는 5일구에서 각각 증가의 정점을 나타냈고 이후 정상치로 되돌아가는 경향을 나타냈다. 2. cortisone acetate는 전신조사후 총혈청단백량에 있어서 5, 10 및 20일구에서 증가의 지체성을 나타냈다. 3. cortisone acetate를 전신조사후 A/G비에 있어서 1, 5 및 10일구에서 증가의 지체성을 나타냈다. 4. 이상의 결과로 미루어 보아 전신조사전 cortisone 처리는 혈청단백질의 방사선 감수성을 감소시킴을 알수 있으므로 방사선 방어효과가 있다고 사료된다. Male mice of strain SM were given 128 rads of single whole-body gamma-irradiation of $^{60}Co$, 14 to 16 minutes following a subcutaneous injection of physiological saline or cortisone acetate (1mg/day, for 4 days preirradiation). The serum protein patterns and the level of the total serum proteins were determined at various time intervals after exposure. Total serum protein was determined by Biuret method and serum protein fractions and A/G ratio were determined by paper electrophoresis using Whatman No.1 filter paper and barbital buffer (pH 8.6, ionic strength 0.06). 1. Total body gamma-irradiation caused a rise in the level of the total serum protein at 1 day and in the level of the serum albumin-globulin ratio at 5 days in both cortisone acetate-treated and control groups. 2. Cortisone acetate delayed the total serum protein rise at 5, 10, and 20 days after exposure. 3. Cortisone acetate delayed the A/G ratio rise at 1, 5, and 10 days after exposure. 4. It may be inferred that cortisone greatly reduces the sensitivity of mice to gamma-irradiation on the blood protein, probided that cortisone is given before the exposure.