RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      검색결과 좁혀 보기

      선택해제
      • 좁혀본 항목 보기순서

        • 원문유무
        • 원문제공처
          펼치기
        • 등재정보
        • 학술지명
          펼치기
        • 주제분류
        • 발행연도
        • 작성언어
        • 저자
          펼치기

      오늘 본 자료

      • 오늘 본 자료가 없습니다.
      더보기
      • 무료
      • 기관 내 무료
      • 유료
      • KCI등재
      • KCI등재
      • KCI등재

        정상 안모가 지니는 비대칭성의 정도에 관한 연구

        채승원,이동주 朝鮮大學校 口腔生物學硏究所 1992 Oral Biology Research (Oral Biol Res) Vol.16 No.1

        This study was undertaken to investigate degree of symmetry in each part of the head and face in normal adult. The subjects consisted of 37 male and 32 female adults, and the average age were 20.9 year old. The analysis of 9 soft tissue linear measurements and 15 skeletal linear measurements from photogrammertry and posteroanterior cephplometric radiograph were caried out. The conclusions were as follow ; 1. Asymmetry was a common finding in normal adult subjects. 2. There was a common finding in normal adult subjects. 2. There was no significant difference on both sexes, but magnitude of facial skeletal structure of male adults more greater than that of famale adults. 3. There was no significant difference between right and left side of craniofacial area of both sexes. 4. When the analysis were undertaken after the head was divided into three parts superoinferioly in the normal male and female adults, the more superior part showed relative stability than more inferior part. 5. Degree of soft tissue asymmetry less than the degree of skeletal asymmetry.

      • SCOPUSSCIEKCI등재

        The effects of fluoride releasing orthodontic sealants on the prevention and the progressive inhibition of enamel demiheralization in vitro

        채승원,윤영주,김광원,Chae, Seung-Won,Cho, Jae-O,Yoon, Young-Jooh,Kim, Kwang-Won The Korean Association Of Orthodontists 1997 대한치과교정학회지 Vol.27 No.6

        고정성 교정장치 주변에 발생되는 백색반점은 임상적으로 쉽게 눈에 띄는 문제점을 가지고 있으므로 잔치제거 후 심니적으로 만족스럽지 못한 결과를 야기하는데, 이는 곧 교정치료의 실패를 의미한다. 이미 많은 연구를 통해 고정성 교정장치가 구강내 세균환경을 변화시켜 세균집단의 증식을 용이하게 함으로써 고정성 장치 부착 후, 법랑질 탈회의 발생빈도가 증가된다는 사실이 보고 되어 왔으며 장기간이 소요되는 교정치료의 특성으로 인해 발생되는 브라켓 또는 교정용 밴드 주변의 법랑질 탈회나 치아우식증을 예방 또는 억제시키기 위한 연구가 함께 진행되어 왔다. 이는 환자에 대한 구강위생 교육이나 치아관리 노력에도 불구하고 발생될 수 있는데 이를 예방하기 위한 방법의 하나로 불소가 유리되는 교정용 전색제를 사용할 수 있다. 본 연구는 불소가 유리되는 광중합형 및 자가중합형 교정용 전색제의 치아우식 예방 및 진행억제효과를 규명하기 위해 다음과 같이 각각 7개의 편광현미경군(A군-G군)과 주사전자현미경군(A'군-G'군)으로 분류하였고 [1. A & A'군 STPP 인공우식용액에 담그지 않은 정상치아군, 2. B & B'군 : STPP 인공우식용액에 담그고 $37^{\circ}C$의 항온용기 에 72시간 보관한 비처치군,3. C & C'군 : STPP 인공우식용액에 담그고 $37^{\circ}C$ 의 항온용기에 72시간 보관한 자가중합형 교정용 전색제군, 4. D &D'군 : STPP 인공우식용액에 담그고 $37^{\circ}C$의 항온용기에 72시간 보관한 광중합형 교정용 전색제군, 5. E & E'군 표면에 아무처리 없이 STPP 인공우식용액에 담그고 $37^{\circ}C$의 항온용기에 72시간 보관한 후, 이를 다시 아무런 처치없이 STPP 인공우식용액에 담그고 $37^{\circ}C$의 항온용기에 72시간 보관한 비처치군, 6. F & F'군 : 표면에 아무런 처치없이 STPP 인공우식용액에 담그고 $37^{\circ}C$의 항온용기에 72시간 보관한 후, 자가중합형 교정용 전색제를 도포하고 이를 다시 STPP 인공우식용액에 담그고 $37^{\circ}C$의 항온용기에 72시간 보관한 자가중합형 교정용 전색제, 7. G & G'군 :표면에 아무런 처치없이 STPP 인공우식용액에 담그고 $37^{\circ}C$ 의 항온용기에 72시간 보관한 후, 광중합형 교정용 전색제를 도포하고 이를 다시 STPP 인공우식용액에 담그고 $37^{\circ}C$ 의 항온용기에 72시간 보관한 광중합형 교정용 전색제군], 이들을 편광현미경과 주사전자현미경을 이용해 조직의 변성 여부를 검색하여 다음과 같은 결과를 얻었다. 1. 편광현미경적 연구에서 인공우식병 소의 깊이는 $A군(5.08{\mu}m),\;B군(47.82{\mu}m,\;C군(8.42{\mu}m),\;D군(7.20{\mu}m),\;E군(85.41{\mu}m),\;F군(60.38{\mu}m),\;G군(60.13{\mu}m)$,이었다. 2. 인공우식 병소의 깊이에 있어서, B군은 A군,C군,D군과 비교하여 통계학적으로 유의성 있는 차이를 보였고(p<0.05), E군은 F군,G군과 비교하여 통계학적으로 유의성 있는 차이를 보였다(p<0.05). 3. 광중합형 및 자가중합형 교정용 전색제는 법랑질탈회 예방효과가 있었다. 4. 광중합형 및 자가중합형 교정용 전색제는 법랑질탈회 진행억제효과가 있었다. 5. 광중합형 및 자가중합형 교정용 전색제 표본에 대한 주사전자현미경적 연구에서 인공우식용액의 시간 경과에 따른 영향은 없었다. 6. 광중합형 교정용 전색제 표본과 자가중합형 교정용 전색제 표본 사이의 차이는 편광현미경과 주사전자현미경으로 구별할 수 없었다. The purpose of this study was to identify the preventive and the progressive inhibitory effects of enamel demineralization with fluoride releasing light-and self-cured orthodontic sealants(FluoroBond), in vitro, under the polarizing light microscope and the scanning electon microscope. The polarizing light microscopic group was subdivided into seven groups(Group A-Group G). The scanning electron microscopic group was also subdivided into seven groups(Group A'-Goup G'). For polarizing light microscopic evaluation, longitudinal sections were made longitudinally by Maruto cutter(Maruto Co., Japan) and Maruto grinding machine(Maruto Co., Japan). Sections were examined and photographed by the polarizing light microscope(Olympus Optical Co., Japan) using crossed polars and with the enamel rod longitudinal axis oriented at $45^{\circ}$ to the extinction position. For scanning electron microscopic evaluation, the specimens were coated with a highly conducting layer of gold palladium in a model Hus-4 high-vacuum evaporator and examined in an ISI-100B scanning electron microcope operated at 20kV. The results of this study were as follows : 1. The mean depths of artificial carious lesions under a polarized light microscope were $Group\;A(5.08{\mu}m),\;Group\;B(47.82{\mu}m,\;Group\;C(8.42{\mu}m),\;Group\;D(7.20{\mu}m),\;Group\;E(85.41{\mu}m),\;Group\;F(60.38{\mu}m),\;Group\;G(60.13{\mu}m)$. 2. There were statistically significant differences in Group B compared with Group A, C, and D(p<0.05), and also, in Group I compared with Group F and Group G(p<0.05). 3. Light-and self-cured orthodontic sealants had the preventive effects of enamel demineralization. 4. Light-and self-cured orthodontic sealants had the progressive inhibitory effects of enamel demineralization. 5. The time progress of demineralizing agent had no influence on the samples of light-and self-cured orthodontic sealants under the scanning electron microscope. 6. There was no difference between the specimens of light-and self-cured orthodontic sealants both in the polarized light microscopic group and in the scanning electron microscopic group.

      • KCI등재
      • KCI등재
      • KCI등재
      • KCI등재
      • SCOPUSSCIEKCI등재
      • KCI등재

        The effects of light-and self-cured orthodontic sealants on the prevention and the progressive inhibition of enamel demineralization in vitro

        Chae, Seung Won,Cho, Jae O,Yoon, Young Jooh,Kim, Kwang Won 朝鮮大學校 口腔生物學硏究所 1997 Oral Biology Research (Oral Biol Res) Vol.21 No.1

        고정성 교정장치 주변에 발생되는 백색반점은 임상적으로 쉽게 눈에 띄는 문제점을 가지고 있으므로 장치제거 후 심미적으로 만족스럽지 못한 결과를 야기하는데, 이는 곧 교정치료의 실패를 의미한다. 이미 많은 연구를 통해 고정성 교정장치가 구강내 세균환경을 변화시켜 세균집단의 중식을 용이하게 함으로써 고정성 장치 부착 후, 법랑질 탈회의 발생빈도가 증가된다는 사실이 보고 되어 왔으며 장기간의 소요되는 교정치료의 특성으로 인해 발생되는 브라켓 또는 교정용 밴드 주변의 법랑질 탈회나 치아우식증을 예방 또는 억제 시키기 위한 연구가 함께 진행 되어 왔다. 이는 환자에 대한 구강위생교육이나 치아관리 노력에도 불구하고 발생될 수 있는데 이를 예방하기 위한 방법의 하나로서 불소가 유리되는 교정용 전색제를 사용할 수 있다. 본 연구는 불소가 유리되는 광중합형 및 자가중합형 교정용 전색제의 치아우식 예방 및 진행억제효과를 규명하기 위해 다음과 같이 각각 7개의 편광현미경군 (A군-C군)과 주사전자현미경군 (A'군-C'군)으로 분류하였고 [ 1. A & A'군: STPP" 인공우식용액에 담그지 않은 정상치아군, 2. B & B'군: STPP 인공우식용액에 담그고 37℃의 항온용기에 72시간 보관한 비처치군, 3. C & C'군: STPP 인공우식용액에 담그고 37℃의 항온용기에 72시간 보관한 광중합형 교정용 전색제군, 5. E & E'군: 표본에 아무런 처치없이 STPP 인공우식용액에 담그고 37℃의 항온용기에 72시간 보관한 후, 이를 다시 아무런 처치없이 STPP 인공우식용액에 담그고 37℃의 항온용기에 72시간동안 보관한 비처치군, 6. F & F'군: 표본에 아무런 처치없이 STPP 인공우식용액에 담그고 37℃의 항온용기에 72시간 보관한 후, 자가중합형 교정용 전색제를 도포하고 이를 다시 STPP 인공우식용액에 담그고 37℃의 항온용기에 72시간 동안 보관한 자가중합형 교정용 전색제군, 7. G & G'군: 표본에 아무런 처치없이 STPP 인공우식용액에 담그고 37℃의 항온용기에 72시간 보관한 후, 광중합형 교정용 전색제를 도포하고 이를 다시 STPP 인공우식용액에 담그고 37℃의 항온용기에 72시간동안 보관한 광중합형 교정용 전색제군], 이들을 편광현미경과 주사전자현미경을 이용해 조직의 변성 여부를 검색하여 다음과 같은 결과를 얻었다. 1. 편광현미경적 연구에서 인공우식병소의 깊이는 A군 (5.08μm), B군 (47.82μm), C군 (8.42μm), D군 (7.20μm), E군 (85.41μm), F군 (60.38μm), G군 (60.13μm) 이었다. 2. 인공우식 병소의 깊이에 있어서 B군은 A군, C군, D군과 비교하여 통계학적으로 유의성 있는 차이를 보였고 (p<0.05), E군은 F군, G군과 비교하여 통계학적으로 유의성 있는 차이를 보여G다(p<0.05). 3. 광중합형 및 자가중합형 교정용 전색제는 법랑질탈회 예방효과가 있었다. 4. 광중합형 및 자가중합형 교정용 전색제는 법랑질탈회 진행억제효과가 있었다. 5. 광중합형 및 자가중합형 교정용 전색제 표본에 대한 주사전자현미경적 연구에서 인공우식용액의 시간 경과에 따른 영향은 없었다. 6. 광중합형 교정용 전색제 표본과 자가중합형 교정용 전색제 표본 사이의 차이는 편광현미경과 주사전자현미경으로 구별할 수 없었다. 주요단어: (광중합형 교정용 전색제, 자가중합형 교정용 전색제, 편광현미경, 주사전자현미경, 법랑질탈회)

      연관 검색어 추천

      이 검색어로 많이 본 자료

      활용도 높은 자료

      해외이동버튼