광열편향법을 이용한 이방성 재료의 열전도계수 측정에 관한 이론적 연구
전필수(Pilsoo Jeon),김현정(Hyunjung Kim),유재석(Jaisuk Yoo) 대한기계학회 2007 대한기계학회 춘추학술대회 Vol.2007 No.5
We have analyzed the three-dimensional thermal conduction in anisotropic materials using nonsymmetric-Fourier transforms. And a complete theoretical treatment of the photothermal deflection spectroscopy has been performed for thermal conductivity measurement in anisotropic medium. Thermal conductivity tensor was determined by the deflection angle and phase angle with the relative position between the heating and probe beams. The influence of the parameters, such as modulation frequency of the heating beam, the thermal conductivity tensor, was investigated.
R-404A/POE 오일 혼합물의 기-액 평형과 상용성에 관한 연구
전필수(Pilsoo Jeon),이광재(Kwangjae Lee),유재석(Jaisuk Yoo),김현정(Hyungjung Kim) 대한기계학회 2006 대한기계학회 춘추학술대회 Vol.2006 No.6
The vapor-liquid equilibrium and miscibility measurement apparatus was developed and used to obtain data for refrigerant/oil mixture. The vapor-liquid equilibrium and miscibility data for R-404A/POE22 and R-404A/POE32 oil mixtures are obtained over the temperature range from -20 to 60℃ with 10℃ intervals and the oil concentration range from 0 to 90 wt%. Using the experimental data, an empirical model is developed to predict the temperature-pressure-concentration relations for R-404A/POE oil mixtures at equilibrium. In the R-404A/POE22 oil mixture, the average root-mean-square deviation between measured data and calculated results from the empirical model is 3.56% and in the R-404A/POE32 oil mixture, that is 3.24%. Flory-Huggins theory is also used to predict refrigerant/oil mixture behavior. Immiscibility for R-404A/POE22 oil mixture was observed all over the oil concentrations. Immiscibility for R-404A/POE32 oil mixture was observed at the 10~70 wt% of oil concentrations.
광열변위법에서 반무한 고체 모델을 이용한 고체재료의 열확산계수 측정
전필수(Pilsoo Jeon),김진화(Jinhwa Kim),김현정(Hyunjung Kim),유재석(Jaisuk Yoo) 대한기계학회 2007 대한기계학회 춘추학술대회 Vol.2007 No.10
The comprehensive model for the thermal diffusivity measurement using photothermal displacement method was developed. In previous works, the thermal diffusivities for solid metal with a finite sample thickness was determined by comparison between the calculated phase curve and the measured one. Therefore, primary error are caused by the finite sample thickness. In this study, a theoretical and experimental treatment of the photothermal displacement technique has been performed for thermal diffusivity measurement in semi-infinite solid materials. The measurement of thermal diffusivity using semi-infinite solid model have the more accurate value because the thickness effect does not exist. In results, the measured values for a semi-infinite materials have the accordance with the literature values within 1% standard deviation, while those for a finite materials show about 3% one.
[가솔린엔진부문] 평행봉 구조물을 이용한 촉매변환기 내 유동분포 개선
민영욱(Younguk Min),전필수(Pilsoo Jeon),이광재(Kwangjai Lee),유재석(Jaisuk Yoo),이종화(Jong-hwa Lee) 한국자동차공학회 2001 한국자동차공학회 춘 추계 학술대회 논문집 Vol.2001 No.11_1
The underbody catalytic converter(UCC) has a problem that the flow entered monolith is concentrated in the center section of monolith. It lead to the decrease of lifetime of UCC by the local deterioration of monolith and the low conversion rate of exhaust gas. In this study the frame with parallel bars was installed in diffuser for the effective flow distribution. Finally. by removing the fixed frame between monoliths the velocity distribution becomes uniform with minor increasement of pressure drop.
윤영선(Youngsun Yun),전필수(Pilsoo Jeon),김현정(Hyunjung Kim),유재석(Jaisuk Yoo) 대한기계학회 2007 대한기계학회 춘추학술대회 Vol.2007 No.5
The interferometer method with nano-scale spatial resolution has been developed in this study. To enhance tile accuracy of the previous developed method, tile 14 bit cooled CCD camera with 1280 by 980 spatial resolution was applied to tile measurement. And optical alignment has been carried out on tile highly accurate position sensors with 500㎚ resolution so as to be able to calibrate the detected interference image with the field of view. Also the measurements were applied to the ultra thin oil film between tile Al coated cylinder mirror with 38.1 ㎜ radius and 0.5㎜ cover glass to verify the developed method. The measured result showed the good agreement with he used cylinder curvature with ±5.18㎚ uncertainty.
오영수(Youngsu Oh),백인기(Ingi Baek),전필수(Pilsoo Jeon),김현정(Hyunjung Kim),유재석(Jaisuk Yoo) 대한기계학회 2007 대한기계학회 춘추학술대회 Vol.2007 No.5
In present study, a temperature field of specimens which was coated with fluorescence dye such as Rhodamine-B(Rh-B) has been measured, based on the fluorescence intensity. Silica(SiO2) nano porous structure with 1um thickness was constructed on a cover glass, and fluorescence dye was digested into these porous thin films. To optimize manufacturing coating process, various solvents, Rh-B concentration, and other chemical materials were applied to fabricate the specimen and all specimens were measured on the various temperature conditions. For the measurement, a 14 bit cooled CCD camera with 1600 by 1200 spatial resolution is equipped with epifluorescence microscope to obtain only fluorescence intensity from 1.2 ㎜ by 0.9 ㎜ field of view of the illuminated coated specimen.
오영수(Youngsu Oh),백인기(Ingi Baek),전필수(Pilsoo Jeon),김현정(Hyunjung Kim),유재석(Jaisuk Yoo) 대한기계학회 2007 대한기계학회 춘추학술대회 Vol.2007 No.10
As the target size of measurement objects lessened to the micro-scale, it is impossible to apply the classical contact methods into temperature measurements. Recently, the LIF technique using fluorescence dye has been used in many research fields to measure temperature. In this study, the specimens with the nano-sized porous thin films are manufactured by injecting fluorescence solution into the glass plate. The optimized manufacturing conditions are determined by the analysis of all parameters that influence to the emission intensity and the experiments are carried out with the specimens produced in the optimized conditions. Then, the deviations of the fluorescence intensity are measured at several different temperatures, and the visualizations of the temperature field are performed by taking intensity distributions from the specimen at various temperature fields.
초발수성 표면처리 효과 및 열선을 이용한 SCR System 내 Mixer의 Urea 고형화 방지 연구
한상수(Sangsoo Han),지수훈(Soohun Gee),전필수(Pilsoo Jeon),윤상원(Sangwon Yun),김경표(Gyungpyo Kim),손민균(Mingyun Son),TURABAEV KOMILJON(Komilzon Turabaev),윤은형(Eunhyung Yun),안승번(Seongbun An),이강원(Gangwon Lee),정재희(Jaehe 한국가스학회 2021 한국가스학회 학술대회논문집 Vol.2021 No.11