http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
Polysulfone으로 Al(OH)<sub>3</sub>를 고정화한 PSf-Al(OH)<sub>3</sub> 비드에 의한 불소 이온의 제거 특성
전진우,이민규,Jeon, Jin-Woo,Lee, Min-Gyu 한국청정기술학회 2014 청정기술 Vol.20 No.1
In this study, PSf-$Al(OH)_3$ beads were prepared by immobilizating aluminum hydroxide $Al(OH)_3$ with polysulfone (PSf). The removal experiments of the fluoride ions by PSf-$Al(OH)_3$ beads were conducted batchwise and the parameters such as pH, initial fluoride concentration, and coexisting ions were investigated. The maximum removal capacity obtained from Langmuir isotherm was 52.4 mg/g and the optimum pH region of fluoride ions was in the range of 4 to 10. The removal process of fluoride ions by PSf-$Al(OH)_3$ beads was found to be controlled by both external mass transfer at the earlier stage followed by internal diffusion at the later stage. The presence of coexisting anions such as $HCO_3{^-}$, $SO{_4}^{2-}$, $NO_3{^-}$, and $Cl^-$ had a negative effect on removal of fluoride ions by PSf-$Al(OH)_3$ beads. 본 연구에서는 폴리술폰(polysulfone, PSf)으로 알루미늄 수산화물(aluminum hydroxide, $Al(OH)_3$)을 고정화한 PSf-$Al(OH)_3$ 비드를 제조하였다. 제조한 PSf-$Al(OH)_3$ 비드에 의한 불소 이온 제거실험은 회분식으로 수행하였으며, pH, 초기농도, 공존이온과 같은 변수들의 영향을 살펴보았다. Langmuir 등온식으로 구한 불소 이온의 최대 제거량은 52.4 mg/g이었으며, 최적 pH 범위는 4~10이었다. PSf-$Al(OH)_3$ 비드에 의한 불소 이온의 제거과정은 전 단계에서 외부물질전달이 나중 단계에서 내부확산이 지배인 것을 알 수 있었다. 또한 PSf-$Al(OH)_3$에 의한 불소 이온의 제거에서 $HCO_3{^-}$, $SO{_4}^{2-}$, $NO_3{^-}$, $Cl^-$와 같은 공존 음이온들은 불소 이온의 제거에 방해를 하는 것으로 나타났다.
이터븀 첨가 능동형 Q-스위칭 광섬유 레이저에서 Q-스위치 상승 시간이 출력 펄스에 미치는 영향에 대한 이론적 분석
전진우,이준수,이주한,Jeon, Jinwoo,Lee, Junsu,Lee, Ju Han 한국광학회 2013 한국광학회지 Vol.24 No.2
본 논문에서는 능동형 Q-스위칭 광섬유 레이저에서 Q-스위치 상승 시간이 출력 펄스에 미치는 영향을 이론적으로 분석하였다. Finite Difference Time Domain (FDTD) 방법을 이용해서 비율 방정식과 전파 방정식에 대한 모델링을 수행하였다. Q-스위칭 광섬유 레이저에서 발생하는 Q-스위칭 펄스의 생성에 있어서 Q-스위치의 상승 시간이 출력 펄스 특성에 미치는 영향을 이론적으로 분석하였다. 또한, Q-스위치의 반복률에 따른 출력 펄스의 에너지 변화와 파형 변화를 확인하였다. Q-스위치 반복률이 높아지고, Q-스위치의 상승 시간이 길어질수록 출력 펄스의 멀티 피크 현상이 줄어들고 안정된 가우시안 형태의 펄스 파형이 발생함을 확인 할 수 있었다. A theoretical analysis of the impact of rise time of a Q-switch on the output pulse performance is carried out in an Ytterbium-doped actively Q-switched fiber laser. The finite difference time domain (FDTD) method is used to numerically simulate the Q-switched fiber laser. It is shown that stable Gaussian-like pulse shape can be generated when the Q-switch rise time is increased and pulse repetition rate is enlarged.
전진우(Jin-woo Jeon),우운택(Woontack Woo) 한국HCI학회 2017 한국HCI학회 학술대회 Vol.2017 No.2
본 논문은 AR 환경에서 이용 가능한 실내 공간내에서 공간과 평면을 분리하여 인식하는 평면 추정방법을 제안한다. 깊이 영상 카메라로부터 지역 법선벡터를 계산한 후 방위, 고도, 거리 정보를 이용하여 비슷한 법선 벡터끼리 군집화한 후 평면을 추정한다. 그 후 평면 영역들로부터 객체 영역을 분리한다. 이 정보를 이용하여 3 차원 공간에서 공간 영역과 물체영역을 분리하여 증강 현실 분야에서 독립적인 응용이 가능하다.
새로운 고경도 Ti-Mo-Si-N 코팅막의 합성 및 기계적 특성
전진우(Jin Woo Jeon),홍승균(Seung Gyun Hong),김광호(Kwang Ho Kim) 한국표면공학회 2006 한국표면공학회지 Vol.39 No.6
In this study, ternary Ti-Mo-N and new quaternary Ti-Mo-Si-N coatings were synthesized on steel substrates (AISI D2) and Si wafers by a hybrid coating system of arc ion plating (AIP) using Ti target and d.c. magnetron sputtering technique using Mo and Si targets in N₂/Ar gaseous mixture. Ternary Ti-Mo-N coatings were substitutional solid-solution of (Ti,Mo)N and showed maximum hardness of approximately 30 ㎬ at the Mo content of ~10 at. %. The Ti-Mo-Si-N coating with the Si content of 8.8 at. % was a composite consisting of fine (Ti,Mo)N crystallites and amorphous Si₃N₄ phase. The hardness of the Ti-Mo-Si(8.8 at. %)-N coatings exhibited largely increased hardness value of ~48 ㎬ due to the microstructural evolution to the fine composite microstructure and the refinement of (Ti,Mo)N crystallites. The average friction coefficient of the Ti-Mo-Si-N coatings largely decreased with increase of Si content. The microstructures of Ti-Mo-Si-N coatings were investigated with instrumental analyses of XRD, XPS, and HRTEM in this work.
병원의 서비스 회복이 공정성 지각과 행동의도에 미치는 영향
전진우 ( Jinwoo Jeon ),백미라 ( Mira Baek ),정기택 ( Keetaig Jung ),이훈영 ( Hoonyoung Lee ) 경희대학교 경영연구원 2015 의료경영학연구 Vol.9 No.3
This research analyzed correspondence effort what the hospital cope with, relation of fairness sensation, fairness and customer satisfaction which is perceived by service recovery, perceived value, hospital image and influencing relationship of future behavior intention to recover service failure. In result of the research, refund and discount among the hospital correspondence effort have a most effect on distribution fairness. This means customers show most positive response about typical output of service recovery strategy. Also, we can know importance of policy, process, tools to support customer`s complain and hospital swift response. Apologize and explanation influences to mutual relation fairness perception positively. Here is intriguing result. procedural justice in contrary with distributive justice and interactional justice doesn```t have a positive affect to perceived value. In other words, typical reward and heartfelt apologize and explanation has positive affect to perceived value, perceived value of policy, process, tools used by decision maker doesn``t have positive affect to customer`s perceived value. On the other hand, customer`s perceived value and satisfaction about perceived justice through service recovery has a positive affect to hospital image, this hospital image has positive affect to future behavior intention. There were multiple researches that can be used for all sorts of things. But, the research for hospital was insufficient. What is important is that we draw an objective research conclusion considering that hospital is one of the service company. Also, in case of medical service failure, it can be used for reference about service recovery method that customers want, and it can be helpful to improvement of medical service quality.
Polysulfone으로 Al(OH)₃를 고정화한 PSf-Al(OH)₃ 비드에 의한 불소 이온의 제거 특성
전진우(Jin-Woo Jeon),이민규(Min-Gyu Lee) 한국청정기술학회 2014 청정기술 Vol.20 No.1
본 연구에서는 폴리술폰(polysulfone, PSf)으로 알루미늄 수산화물(aluminum hydroxide, Al(OH)₃)을 고정화한 PSf-Al(OH)₃ 비드를 제조하였다. 제조한 PSf-Al(OH)₃ 비드에 의한 불소 이온 제거실험은 회분식으로 수행하였으며, pH, 초기농도, 공존이온과 같은 변수들의 영향을 살펴보았다. Langmuir 등온식으로 구한 불소 이온의 최대 제거량은 52.4 mg/g이었으며, 최적 pH 범위는 4~10이었다. PSf-Al(OH)₃ 비드에 의한 불소 이온의 제거과정은 전 단계에서 외부물질전달이 나중 단계에서 내부 확산이 지배인 것을 알 수 있었다. 또한 PSf-Al(OH)₃에 의한 불소 이온의 제거에서 HCO3-, SO₄<SUP>2-</SUP>, NO3-, Cl<SUP>-</SUP>와 같은 공존 음이온들은 불소 이온의 제거에 방해를 하는 것으로 나타났다. In this study, PSf-Al(OH)₃ beads were prepared by immobilizating aluminum hydroxide Al(OH)₃ with polysulfone (PSf). The removal experiments of the fluoride ions by PSf-Al(OH)₃ beads were conducted batchwise and the parameters such as pH, initial fluoride concentration, and coexisting ions were investigated. The maximum removal capacity obtained from Langmuir isotherm was 52.4 mg/g and the optimum pH region of fluoride ions was in the range of 4 to 10. The removal process of fluoride ions by PSf-Al(OH)₃ beads was found to be controlled by both external mass transfer at the earlier stage followed by internal diffusion at the later stage. The presence of coexisting anions such as HCO3-, SO₂<SUP>2-</SUP>, NO3-, and Cl<SUP>-</SUP> had a negative effect on removal of fluoride ions by PSf-Al(OH)₃ beads.