http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
셀레늄과 세라믹 혼합분말을 사용한 Cu<sub>0.9</sub>In<sub>0.7</sub>Ga<sub>0.3</sub>Se<sub>2</sub> 분말층의 소결거동 연구
송봉근,황윤정,박보인,이승용,이재승,박종구,이도권,조소혜,Song, Bong-Geun,Hwang, Yoonjung,Park, Bo-In,Lee, Seung Yong,Lee, Jae-Seung,Park, Jong-Ku,Lee, Doh-Kwon,Cho, So-Hye 한국태양광발전학회 2014 Current Photovoltaic Research Vol.2 No.3
$Cu(In,Ga)Se_2$ (CIGS) thin films have been used as a light absorbing layer in high-efficiency solar cells. In order to improve the quality of the CIGS thin film, often selenization step is applied. Especially when the thin film was formed by non-vacuum powder process, selenization can help to induce grain growth of powder and densification of the thin film. However, selenization is not trivial. It requires either the use of toxic gas, $H_2Se$, or expensive equipment which raises the overall manufacturing cost. Herein, we would like to deliver a new, simple method for selenization. In this method, instead of using a costly two-zone furnace, use of a regular tube furnace is required and selenium is supplied by a mixture of selenium and ceramic powder such as alumina. By adjusting the ratio of selenium vs. alumina powder, selenium vaporization can be carefully controlled. Under the optimized condition, steady supply of selenium vapor was possible which was evidently shown by large grain growth of CIGS within a thin powder layer.
송봉근,박경훈,Song, Bong-Geun,Park, Kyung-Hun The Korean Association of Geographic Information S 2017 한국지리정보학회지 Vol.20 No.3
본 연구는 대한민국 창원시의 도시지역을 대상으로 현장에서 측정된 표면온도자료를 활용하여 토지이용유형별로 ASTER 표면온도 자료의 정확성을 분석하고 보정모형을 도출하고자 하였다. 토지이용유형은 공원과 상업시설, 단독주택, 아파트를 고려하여 총 8개를 선정하였다. ASTER 표면 온도는 2012년부터 2014년까지 6월과 9월에 촬영된 주간 및 야간의 8개 영상을 수집하였고, 현장측정은 위성영상이 촬영된 시간과 동일한 시기에 실시하였다. 또한 현장에서 측정된 표면온도의 방사보정을 위해 5일 동안 21개의 토지피복재질에 대해 방사율을 측정하였다. 주간시간은 현장에서 측정된 표면온도가 위성영상의 것보다 약 $5{\sim}10^{\circ}C$ 정도 높았고, 건물의 밀집된 지역일수록 차이가 큰 것으로 분석되었다. 표면온도 보정모형은 도시공원을 제외한 나머지 지역에서 설명력이 60%로 모형의 신뢰성이 있다고 분석되었다. 야간시간은 여름철인 8월을 제외하고 주간시간과 반대로 ASTER 표면온도가 약 $2^{\circ}C$ 다소 높은 것으로 분석되었다. 그러므로 위성영상의 표면온도를 활용하기 위해서는 반드시 현장자료를 바탕으로 정확성을 검증하고 보정할 필요가 있다. 본 연구의 결과는 이러한 측면에서 매우 의미가 있으며, 앞으로 도시지역의 열섬 문제를 개선하기 위해 도시 및 환경계획 분야에서 활용가치가 뛰어날 것으로 생각된다. This study aimed to validate the ASTER surface temperature using field measurements over various land use types in the urban area of Changwon City, South Korea. The ASTER surface temperature was measured by collecting eight images during daytime and nighttime in June and September from 2012 to 2014, and field measurements were conducted over the same period when the satellite images were taken. The analyses showed that the surface temperature measured in the field during the daytime was higher than that of satellite imageries by $5{\sim}10^{\circ}C$, and the gap was higher in built-up areas. The calibration models of surface temperature showed a 60% explanatory power in areas other than parks, indicating that the models are reliable. During nighttime, except for the summer month of August, ASTER surface temperature was determined to be approximately $2^{\circ}C$ higher in contrast to daytime.
순환기 내과 환자를 대상으로 한 심부전의 정도와 NT-pro BNP의 혈중 농도와의 관계 분석: 순환기 내과 외래 환자와 입원 환자를 중심으로
송봉근 ( Song Bong Geun ),전은석 ( Jeon Eun Seog ),김용훈 ( Kim Yong Hun ),강민경 ( Kang Min Gyeong ),도준형 ( Do Jun Hyeong ),김필호 ( Kim Pil Ho ),안석진 ( An Seog Jin ),오혜림 ( O Hye Lim ),김현중 ( Kim Hyeon Jung ),성지동 ( Se 대한내과학회 2004 대한내과학회지 Vol.66 No.1
Background : N-terminal fragment of pro Brain Natriuretic Peptide (NT-pro BNP) is a neuro-hormone synthesized from the cardiac ventricles in response to increased wall tension. The purpose of this study was to assess the correlation between NT-pro BNP lev
도시지역의 바람길 조성을 위한 야간시간대의 공기순환성 평가
송봉근 ( Bong Geun Song ),박경훈 ( Kyung Hun Park ) 한국지리정보학회 2013 한국지리정보학회지 Vol.16 No.2
본 연구는 경상남도 창원시를 대상으로 MetPhoMod 모델링의 야간시간대 바람패턴결과를 이용하여 공기순환성 평가를 실시하였다. 공기순환성 평가는 바람의 지속성과 교란성의 평가지수를 이용하여 분석하였으며, 바람의 지속성은 바람패턴의 풍속, 바람의 교란성은 풍향의 다양성 결과를 활용하였다. 분석결과 도시지역 중 공기순환성이 취약한 지역은 봉림동, 용지동, 반송동 등으로 나타났으며, 특히 용지동과 상남동, 사파동의 고층아파트 및 상업지역, 단독주거지역에서 바람정체현상이 발생하는 것으로 확인되었다. 따라서 이러한 공기순환성이 취약하여 바람정체현상이 발생하는 지역에 대해 공간개선을 함으로써 바람의 유동이 원활할 수 있도록 조성되어야 할 것이며, 도시외곽에서 생성되는 바람이 지속적으로 유입될 수 있도록 개발계획차원에서 바람길 조성 방안이 마련되어야 할 것으로 판단된다. The purpose of this study is to evaluate air ventilation using wind patterns of MetPhoMod program at nighttime focused on Changwon-si, Gyeongsangnam-do. Evaluation indices of air ventilation are wind resistant and retention used by results of each wind speed and diversity. The results are as follows. Vulnerable areas of air ventilation are Bonglim-dong, Bansong-dong, Yongji-dong and so on. In high-rise apartment, commercial area and single residential area of Yongji-dong, Sangnam-dong and Sapa-dong, wind is stagnated by high buildings. Therefore, these areas should construct urban spaces to circulate the wind. And to inflow persistingly the fresh wind generated in a rural area, we think that the construction of wind corridor is suggested by development plan and policy wind corridor.
연구논문 : GIS 기반의 물순환 면적률을 활용한 창원시 도심지역의 물순환성 평가
송봉근 ( Bong Geun Song ),박경훈 ( Kyung Hun Park ),이택순 ( Taek Soon Lee ) 한국환경영향평가학회 2013 환경영향평가 Vol.22 No.5
The purpose of this study is to analyze water cycle area ratio and spatial evaluation of water cycle in urban area of Changwon-si, Gyeongsangnam-do. Water cycle area ratio are analyzed by using spatial data of land-cover and land-use, and Hot spot analysis of GIS program was used for spatial evaluation of water cycle. The results are as below. Firstly, the high water cycle area ratio areas were forests, parks, and rivers, but urban areas covered asphalt and concrete were low under 40%. Public institutions and co-residential of urban areas were higher than others because of high area ratio of pervious land-cover. Spatial evaluation of water cycle was analyzed to vulnerable areas there are dense residential and commercial area. These areas are really occurring frequently flooding and immersion, therefore, is required water management facilities and improvement of land-cover from impervious to pervious. In the future, it will require additionally analysis of water cycle area ratio supplemented data of water management facility and ground water.
도시열섬완화를 위한 토지 이용 유형별 합리적 녹지율 분석
송봉근 ( Bong Geun Song ),박경훈 ( Kyung Hun Park ) 한국지리정보학회 2015 한국지리정보학회지 Vol.18 No.2
본 연구는 다양한 토지이용유형별로 도시열섬현상을 완화하기 위한 합리적 녹지율을 분석하고자 하였다. 토지이용유형은 단독주택과 공동주택, 공공시설, 상업지역, 공업지역의 5가지 유형을 고려하였고, 녹지지역은 토지피복도에서 수목 속성을 추출하여 활용하였다. 열섬효과는 주간 및 야간에 촬영된 다중시기의 ASTER TIR 영상의 표면온도를 이용하였다. 주간시간은 야간시간보다 녹지의 표면온도 저감 효과가 큰 것으로 나타났다. 토지이용유형별로는 주간시간에 단독주택에서 녹지율에 따른 표면온도 저감효과가 가장 뚜렷했지만, 야간시간에는 토지이용유형별로 차이가 크지 않았다. 공업지역은 녹지의 표면온도 저감 효과가 낮았다. 토지이용유형별 도시열섬완화를 위한 합리적 녹지율을 산출한 결과, 주간시간은 단독주택과 공동주택, 상업지역에서 녹지율이 40~50% 사이일때, 표면온도가 가장 낮았고, 야간시간은 녹지율별로 표면온도 변화가 크지 않았다. 따라서 본 연구의 결과는 도시개발계획 단계에서 도시열섬완화를 위해 효과적인 녹지면적을 제시할 수 있을 것으로 판단된다. The purpose of this study is to analyze reasonable green area ratios for mitigating urban heat island considering various land use types. Land uses of 5 types such as single residential, multi residential, commercial area, public facility, and industrial area were considered. Green areas were extracted from the tree attribution of land cover. Effect of urban heat island was analysed by the surface temperature of ASTER thermal infrared radiance scanned daytime and nighttime. Mitigation effect of green area at daytime was higher than nighttime. Surface temperature of green area was low in single residential at daytime. But the difference of surface temperature by each land use type was small. The effect of surface temperature mitigation of green area was lower in industrial area. The results of reasonable green area ratios for mitigating urban heat island indicate that surface temperature was the lowest with green area ratio of 40~50% in single residential, multi residential, and commercial area at daytime. Surface temperature of nighttime was not changed much by green area ratios. Therefore, the results of this study will be suggested in urban development planning to construct effectively green area for mitigating urban heat island.