http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
안운선,손용근,류은아,이광순,Woon Sun Ahn,Yong Keun Son,Eun Ah Yoo,Kwang Soon Lee 대한화학회 1981 대한화학회지 Vol.25 No.4
흑연 표면(0001)에 흡착한 Kr 분자를 2D 기체로 보고 Kr-흑연의 상호작용 에너지와 Henry 상수 $K_H$를 Fourier series expansion에 의해서 해석함수로 구하였다. 그리고 2D virial계수 $B_{2D}$와 $C_{2D}$를 계산하여 2D 상태방정식을 얻었으며, 이것으로 부터 구한 흡착등온곡선을 실험 결과와 비교하였다. 상호작용 에너지는 Lennard-Jones (12, 6) 퍼텐셜의 pairwise additivity로 가정하였으며, 사용한 파라미터는 ${\varepsilon}_{gs}$/k = 70 K, ${\sigma}_{gs}$ = 0.35 nm, ${\varepsilon}_{gg}$/k = 170 K 및 ${\sigma}_{gg}$ = 0.37 nm이다. Assuming krypton molecules adsorbed on graphite surface as 2D gas, the interaction energy of Kr-graphite and the Henry's constant are calculated analytically by the Fourier series expansion method. 2D virial cofficients, $B_{2D}$ and $C_{2D}$, are also calculated to obtain 2D equation of state, and hence adsorption isotherms. The isotherms so obtained are compared with experimental results reported by Putnam and Fort. The pairwise additivity of Lennard-Jones(12, 6) interaction energy is also assumed, and parameters therein are taken as; ${\varepsilon}_{gs}$/k = 70 K, ${\sigma}_{gs}$ = 0.35 nm, ${\varepsilon}_{gg}$/k = 170 K, and ${\sigma}_{gg}$ = 0.37 nm.
금 처리를 통한 PEDOT 마이크로튜브 전극의 과산화수소 검출 특성 향상
박종서(Jong Seo Park),손용근(Yong Keun Son) 한국고분자학회 2014 폴리머 Vol.38 No.6
전류 감응형 바이오센서에 응용하기 위해 전도성 고분자 마이크로튜브 어레이를 제작하였다. Poly(3,4-ethylenedioxythiophene)/poly(4-styrenesulfonic acid)(PEDOT/PSS) composite을 전도성 접착제로 하여 템플릿을 전극에고정한 후 EDOT을 전기화학적으로 중합하였다. 마이크로튜브 어레이는 자체의 넓은 표면적으로 인해 감도 높은바이오센서로 응용될 수 있으나, 주요 표적물질 중의 하나인 과산화수소에 대한 전기화학적 반응이 느렸다. 과산화수소 산화에 대한 감도를 향상시키기 위해 어레이 전극에 금을 도포하였다. 증착법과 전기화학적 석출법 두 가지방법을 시도하여 금을 처리하였는데, 이렇게 처리한 전극은 모두 과산화수소에 대한 반응이 크게 향상되었다. 따라서 전도성 고분자 마이크로튜브 어레이에 금을 도포함으로써 과산화수소를 표적물질로 하는 감도 높은 바이오센서제작이 가능할 것으로 기대된다. An array structure of conducting polymer microtubule was fabricated for an amperometric biosensor. 3,4-Ethylenedioxythiophene(EDOT) was electropolymerized in the microporous template membrane with poly(3,4-ethylenedioxythiophene)/poly(4-styrenesulfonic acid) (PEDOT/PSS) composite as a binder. The array structure can provideenhanced current collecting capability due to large active surface area compared to the macroscopic area of the electrodeitself. For a biosensor application, the array electrode was tested for H2O2 detection and showed very sluggish electrochemicalresponse to H2O2. To enhance the detection efficiency to the oxidation of H2O2, gold was treated on the electrodeby two different approaches: sputtering and electrochemical deposition. Gold treatment with either method greatlyenhanced the sensitivity of the electrode to H2O2. So, conducting polymer microtubule array with gold treatment wasexpected to be a sensitive amperometric biosensor system based on the detection of H2O2.
Photoselection Spectroscopy of Polyaniline and Dynamic Excition Effect on Carrier Size
Son, Yong-Keun 성균관대학교 기초과학연구소 1994 論文集 Vol.45 No.1
전도성 고분자 폴리아닐린 안에 생성되는 전하 캐리어의 동적 크기결정에 중요한 인자인 엑시톤의 운동을 관찰하기 위하여 선택편광 분광 연구를 하였다. 온도에 따라 달라지는 형광의 편광 자료를 얻어 이를 페린 식을 이용하여 분석하여본 결과 엑시톤의 운동이 매우크게 나타남을 알 수 있었다. An in situ application of Photoselection Spectroscopy to a conducting polymer, polyaniline(PAN), to investigate the effect of exciton dynamics to the size of the charge carrier in the polymeric media. Temperature dependent polarization data were obtained and analyzed via Perrin equation. It has been found that exciton movement contributes significantely to the carrier size.