http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
김진후(Kim Jin-Hoo),박경원(Park Kyung-Weon),김현도(Kim Hyun-Do) 동아대학교 해양자원연구소 2000 동아대학교 해양자원연구소 연구논문집 Vol.13 No.-
A marine seismic exploration with the 400㎐ bubble pulser 1200 system was carried out.<BR> The seismic survey was conducted along the 5 survey lines(total length of 4㎞), and the aim of this survey was to profile depth of sediment layer and bedrock with SINCDAS(Single Channel Data Acquisition System) developed by this study. The field data is displayed with variabel-density method and compared with borehole log to confirm accuracy of seismic data interpretation.<BR> The subsurface structure consists of the upper clay layer and the lower silt-clay layer. But the bedrock depth is not found because of extremely shallow survey depth and multiple reflections.
김상용(Sang Yong Kim),박경원(Kyung Weon Park),갈철우(Cheol Woo Gal),최숙희(Sook Hee Choi),김현주(Hyun Ju Kim),백영철(Young Chul Beak),오대식(Dae Sik Oh),성훈(Hoon Seong) 대한산부인과학회 2001 Obstetrics & Gynecology Science Vol.44 No.9
N/A Objective:We report six patients with tuboovarian abscess(TOA) drained through sonographically guided transrectal route, in whom percutaneous or transvaginal approach was not accessible due to the risk of pelvic organ. Method : This procedure was performed under the guidance of transrectal ultrasound. Six patients with aged 25-42years (mean31.6years), who had appendectomy(1), C/S(2), hyterectomy(1) and no operaion Hx(2). Size of abscess cavity was variable from three to eight centimeter. Catheter was removed when drainage amount was reduced less than 10cc and the patient becomes afebrile. Result : Drainage was successfully done in all patients without any complication to the procedure. Fecal contamination was not occurred after transrectal drainage due to abdominal pressure and gravity ought to empty the abscess cavity. There was no problem in defecation due to the catheter and in its expulsion by defecation. Catheter was removed after 3-8days (mean 6days) without recurrent abscess . Conclusion : Transrectal drainage of abscess performed with ultrasound guidance is a safe, feasible procedure, which is well tolerated by patient and relatively easy procedure
경질 초음파유도하의 경질 배액술을 이용한 난관 난소 농양의 치료
유인영(In Young Yoo),김상용(Sang Yong Kim),박성근(Seong Kun Park),갈철우(Cheol Woo Gal),박경원(Kyung Weon Park),이정형(Jeong Hyung Lee),김문종(Moon Jong Kim),성훈(Hoon Seong) 대한산부인과학회 2000 Obstetrics & Gynecology Science Vol.43 No.9
난소 난관 농양은 항생제만으로도 치료가 효과적일 수 있지만, 배농한 후에 항생제 병용치료할 때 더욱 치료 성적이 좋다. 배농의 방법은 여러 가지가 있으며, 여기에서는 본원에서 시행된 초음파 유도하에 이루어진 경질 배액술 5 예를 보고하고 임상적 의의를 살펴 보고자 한다. 1998년 1월부터 1999년 9월까지 난관 난소농양으로 진단 받고 초음파 유도하에 경질 배액술을 시행받은 환자의 입원기간, 합병증 발생유무, 시술후 합병증 등을 분석하였다. 시술한 환자들의 평균 연령은 32.4 세 였으며, 농양의 크기는 5-10 cm으로 다양하였고, 평균배농기간은 6.4 일 이었으며 시술중 합병증은 없었고, 시술후 3 개월간 초음파 추적결과 재발 및 수술이 필요한 경우는 없었다. 경질배액술을 이용한 난관 난소농양의 치료는 효과적이고도 안전하며, 농양이 질과 인접한 경우에는 더욱 손쉽게 시행할 수 있다. Often, women with Tuboovarian abscess (TOA) will reponse to antimicrobial therapy alone, additionally after drainage of abscess, antimicrobial therapy is more effective. Method of drainage is several, author present 5 cases that Tuboovarian abscess by transvaginal sonographically guided drainage in our hospital. From January 1998 to september 1999, transvaginal sonographic guidance proceduers for Tuboovarian abscess were successfully performed on 5 cases in a fluoroscopy room Equipments for the technique included a 18 gauge Chiba needle, plastic introducer tube, guide-wire and 18F multipurpose locking catheter. No major complication or recurrence were experienced. After initial catheter placement, patients became afebrile within 6 days ( average 3.4 days ). Catheters were removed within 10 days ( average 6 days ) after insertion. Five patients recovered without surgery and required no further treatment. Treatment of Tuboovarian abscess used by transvaginal sonographically guided drainage is effective and safe, in cases of close to vagina.
박경원,김진후 東亞大學校 海洋資源硏究所 1997 硏究論文集 Vol.10 No.1
These days, while lots of excavating remains are proceeding in ground and underwater of old sites, there are much remains that don't discover in underwater or underground, yet. Not only is difficult finding where the remains are, but especially there isn't any effort to find the remains in underwater or the deep part of the bottom contrary to the ground remains because of the harsh environment, technical problems and so on. Thus, we tried to find them in the underwater and the deep part of the bottom by marine geophysical surveys. We found the old sites where they are buried very much using SBP(sub-bottom profiler), magnetometer, marine metal detector and so forth, and lifted after taking off sands, gravel and shellfish about 2 m depth, using air-lift with SCUBA.
김진후,박경원,김현도 동아대학교 해양자원연구소 2000 硏究論文集 Vol.13 No.1
A marine seismic exploration with the 400Hz bubble pulser 1200 system was carried out The seismic survey was conducted along the 5 survey lines(total length of 4km), and the aim of this survey was to profile depth of sediment layer and bedrock with SINCDAS(Single Channel Data Acquisition System) developed by this study. The field data is displayed with variabel-density method and compared with borehole log to confirm accuracy of seismic data interpretation. The subsurface structure consists of the upper clay layer and the lower silt-clay layer. But the bedrock depth is not found because of extremely shallow survey depth and multiple reflections.