손영욱(Y.U. Sohn),박인수(I.S. Park),권세진(S.J. Kwon),김영찬(Y.C. Kim),손정봉(J.B. Son),김경렬(K.R. Kim),정진화(C.W. Chung),전중환(J.H. Chun),류지윤(J.Y. Ryu) 한국유체기계학회 2003 유체기계 연구개발 발표회 논문집 Vol.- No.-
Load calculation is indispensable for the construction of a large wind turbine generator system (WTGS). In procedures of load calculation, all conditions affecting to WTGS such as environment of site, operation, transport and installation have to be considered systematically. So the certification of WTGS is issued by assuring the load calculation. This work shows the generals of load calculation briefly and introduces the characteristics and results of load calculations for the 750 ㎾ direct-drive WTGS (KBP-750D) which is under development by the consortium of POSTECH and UNISON.