RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      검색결과 좁혀 보기

      선택해제
      • 좁혀본 항목 보기순서

        • 원문유무
        • 원문제공처
          펼치기
        • 등재정보
        • 학술지명
          펼치기
        • 주제분류
          펼치기
        • 발행연도
          펼치기
        • 작성언어
        • 저자
          펼치기

      오늘 본 자료

      • 오늘 본 자료가 없습니다.
      더보기
      • 무료
      • 기관 내 무료
      • 유료
      • KCI등재

        雲溪 金鍾正 尙書論의 특징

        김만일(Kim Manil) 고려사학회 2011 한국사학보 Vol.- No.43

        Kim Jong-jeong(1722~1787) was a Confucian scholar who worked during the era of King Yeonjo(英祖) and Jeongjo(正祖) in the later Joseon Dynasty. An abundance of detailed commentaries on Shang Shu(尙書: the Book of Historical Documents, a.k.a. Shu Jing(書經); Classic of History) are included in the collection of his works called Ungye mango(雲溪慢稿). In his commentaries the texts of Shang Shu are listed with explanatory notes of Shu Ji Zhuan(書集傳; A Collection of Comments on the Shu) by Cai Chen(蔡沈) who was one of Zhu Xi(朱熹)’s eminent disciples. which shows he accepted Cai’s notes that is based on Zhu Xi’s neo-Confucianism as most reasonable and reliable one among many other notes on Shang Shu. At the same time, however. he also adopted the pre-neo-Confucian system of notes of Shang Shu Zheng Yi(尙書定義 ; The Correct Meaning of the Book of Historical Documents by Imperial Authority) written by Kong Ying Da(孔穎達) in the Tang dynasty, Kim evaluated Zhu Xi’s notes on the place names in Shang Shu as an unfinished and open ones, which shows his characteristic attitude to established notes. He was active to accept the existing notes, but also sceptical of the existence of perfect note. His attitude conflicted with the then current neo-Confucianists’ view on Zhu Xi’s notes. He thought that the established note system of Confucian Classics should be challenged as times have changed. Another notable feature of his commentaries is that he accepted the notes of the Joseon Dynasty’s scholars as much as Chinese scholars. He accepted the notes on Shang Shu of Kim Jang-saeng(金長生), Song Si-yeol(宋時烈), Kim Chang-heup(金昌翕), Kim Chang-hyeop(金昌協), and so on. This was an unparalleled attempt in the history of Shang Shu commentaries in the Joseon Dynasty. Kim Jong-jeong tried to examine theories on Shang Shu’s formation and the problem of authenticity about Shang Shu written in Jinwen (今文: current script in Han Dynasty) or Guwen(古文: ancient script), and he also cast doubt on the reliability of forewords to each chapters of Shang Shu called Shuxu(書序). His examination and criticism was focused on Shang Shu per se while most scholars in the Joseon Dynasty immersed themselves in textual critic. Before Dasan(茶山) Jeong Yak-yong(丁若鏞) this kind of attitude was so rare that Kim’s criticism on Shang Shu was significant in the history of Shang Shu commentaries in the Joseon Dynasty. Kim also criticised existing Korean annotations of Shang Shu and proposed amendments. He asserted that Korean annotations did not reflect Shu Ji Zhuan with an accuracy. In this case we can recognize that Kim Jong-jeong acknowledged the superiority of the note system of Cai Chen’s Shu Ji Zhuan.

      • KCI등재

        Soil-Bentonite 혼합토의 불포화 투수특성 연구

        김만일 ( Man Il Kim ) 대한지질공학회 2005 지질공학 Vol.15 No.2

        본 연구에서는 폐기물 매립장의 차수층으로 사용되는 벤토나이트 혼합토에 대한 연직침윤시험과 Frequency Domain Reflectometry 측정장비를 이용한 유전율 측정시험을 수행하였다. 표준사, 화강풍화토, 벤토나이트 재료에 대해 다양한 배합 비율을 적용하여 제작된 벤토나이트 혼합토의 체적함수비, 간극비, 유전율상수 등의 관계로부터 이들의 불포화 투수 특성을 파악하였다. 연구결과에 따르면 초기 벤토나이트 혼합비는 체적함수비 변화에 영향을 미치며, 체적함수비 변화는 간극비와 밀접한 관계를 가지고 있다. 또한 벤토나이트 혼합토의 체적함수비 변화는 유전율 반응으로부터 명확히 측정됨을 파악하였다. 벤토나이트 혼합토의 불포화 투수 특성을 파악하기 위한 본 연구에서 체적함수비와 유전율상수의 관계함수를 추정하였다. This study presents the results of a laboratory investigation performed to study physical properties of soil-bentonite mixtures through the vertical permeation test and dielectric measurement test using Frequency Domain Reflectometry system for the liner of waste landfill. For the laboratory experiments, geotechnical testing was conducted on pre-mixed soil-bentonite which is consisted of standard sand, weathered granite soil and bentonite for estimating physical parameters such as a volumetric water content, void ratio and dielectric constant. In experiment results, initial soil-bentonite mixing rate has an effect of change of volumetric water content. Also change of volumetric water content of a soil-bentonite mixture is clearly detected to measure a response of dielectric constant. In order to estimate an unsaturated permeable property of soil-bentonite mixtures, equations between volumetric water content and dielectric constant were derived from this study.

      • KCI등재

        백색침출수 용출지역의 수리지질학적 고찰

        김만일 ( Man Il Kim ),박영규 ( Young Gyu Park ),을영 ( Eul Young Kim ),양빈 ( Yang Bin Kim ),용환호 ( Hwan Ho Yong ),지원현 ( Won Hyun Ji ) 대한지질공학회 2010 지질공학 Vol.20 No.4

        본 연구는 백색침출수 용출구간에 대한 수리지질학적 특성을 파악하기 위한 목적으로 수행되었다. 이를 위하여 지표지질조사를 통해 지질특성을 분석하였으며, 백색침출수 용출구간의 지질구조를 파악하기 위한 전기비저항탐사와 시추공 공내촬영을 통해 암반의 불연속면 분포특성을 분석하였다. 연구지역 내 백색침출수 용출지점을 중심으로 갈수기와 풍수기로 구분하여 강우사상에 따른 지하수위 변동을 시추공별로 측정하였다. 이상의 연구결과에서 백색침출수 용출구간에서의 전기비저항특성은 비용출구간에 비해 상대적으로 낮은 값으로 나타났으며, 이는 심부에 파쇄대 내지 석회암 공동대의 존재를 확인하였다. 이들 지역에서의 강우사상에 따른 지하수위 변동을 지하수 유형분석을 통해 분석한 결과, 강우가 직접적으로 지하수 함양에 영향을 주는 것으로 파악되었다. 또한 일평균 유출량과 강우량의 상관관계 분석에서 0.83~0.97로 높은 상관성을 갖는 것으로 나타났다. This study assessed the hydrogeological characteristics of a seepage area of white leachate. The geological characteristics of the leachate were determined by a surface survey, and an electrical resistivity survey and borehole image processing system (BIPS) were applied to estimate the distribution of discontinuities, to assess the geological structure of the seepage areas. Fluctuations in groundwater level within boreholes were measured during periods of precipitation in the dry and wet seasons. The results show that electrical resistivity is lower in the seepage section than in non-seepage sections. The distribution of fracture zones and limestone cavities was inferred from the logging data and BIPS data. Variations in groundwater level and groundwater recharge, related to rainfall events, show the direct effect of rainfall events during the rainy season. We obtained a strong relationship between seepage amount and rainfall (correlation coefficients of 0.83-0.97).

      • KCI등재

        지하수 검층을 위한 새로운 유전율 추적자 시험법의 개발

        김만일 ( Man Il Kim ),형수 ( Hyoung Soo Kim ),정교철 ( Gyo Cheol Jeong ) 대한지질공학회 2004 지질공학 Vol.14 No.3

        다공질매질을 구성하고 있는 다양한 매질들의 전기적 특성 중의 하나인 유전율상수를 이용하여 지하수 유동 및 매질의 구조를 파악하기 위한 새로운 유전율추적자시험법(dielectric tracer test method)을 본 연구에서 제안하였다. 추적자물질로는 비중이 물과 동일한 에탄올혼합액체(ethanol mixing liquid, EML)를 제작하였으며, 각기 다른 공극률을 갖는 포화 표준사 및 강모래 층에 대해 매질의 유전율상수를 측정할 수 있는 FDR system 및 측정센서를 적용해 추적자시험을 실시하였다. 또한 이들의 결과와 비교하기 위하여 추적자물질인 염분농도 3%를 갖는 염분수용액의 농도 변화를 electro multi-meter로 측정하여 비교 검토하였다. 두 시험결과에서 EML 추적자시험의 경우, 각각의 포화 흙칼럼에서의 EML 농도변화를 명확히 확인할 수 있었으나, 염분수용액을 적용한 시험에서는 이들이 지속적으로 칼럼 내 하단부로 침전되어 염분농도 변화에 의한 물의 침투 이동은 확인할 수 없었다. 이는 염분수용액의 비중이 물보다 무겁기 때문에 포화토 내 물의 이동 속도에 비례하여 지속적으로 하단부로 침전이 이루어지는 것을 알 수 있었다. 그러므로 본 연구에서는 물의 비중과 동일한 EML 추적자물질과 이들의 유전율상수 변화를 측정할 수 있는 FDR system을 적용하여 유전율추적자시험의 적용 가능성을 실내추적자시험을 통하여 확인하였다. This study is suggested a new dielectric tracer test method to understand geological structure of porous media and groundwater flow to use the dielectric constant which is one of electrical special quality of various geological materials. To measure their parameters, tracer material is made an ethanol mixing liquid(EML) having a same specific gravity of water. Also, soil materials are prepared a dielectric tracer test using the FDR system that could measure dielectric constant for saturated standard sand and river sand layers which have different initial porosity. To compare with their results, we discussed with the concentration variation of saline water having a saline concentration 3% which is general tracer material by using the electro multi-meter system in the laboratory or field test. In two tracer experiment results, EML tracer test could confirm definitely EML concentration variation from each saturated soil layer as standard and river sands. However, tracer test of saline water 3% concentration could not confirm permeating movement of water by degree of salinity change because these are settled at lower part column in a whole column area continuously. These causes are that specific gravity of saline water is heavier than water. That is, it could know that deposition of saline water is composed of lower part of soil column continuously independently of the direction of water into saturated soil material.

      • KCI등재

        지하댐 지반 물성치 측정을 위한 유전율 측정 시스템 개발

        김만일 ( Man Il Kim ),정교철 ( Gyo Cheol Jeong ),박창근 ( Chang Kun Park ) 대한지질공학회 2004 지질공학 Vol.14 No.4

        매질이 가지는 고유의 유전율 특성을 이용하여 체적함수비를 실시간으로 측정할 수 있는 유전율 측정장비인 Frequency Domain Reflectometry (FDR) system 및 측정센서를 제안하였다. 특히 측정센서의 형태는 7cm, 10cm, 15cm 길이로 각기 제작하여 유전율상수의 특성을 파악하였다. 본 장비의 유전율측정은 0.1~1.7GHz의 고주파수 범위 내에서 발생된 전자파를 방향성결합기를 통과하여 매질에 설치된 측정센서에서 입사파와 반사파의 간섭현상을 이용함으로써 측정이 가능하다. 본 실내시험 연구에서 획득된 연구결과는 유전율상수의 변화로부터 체적함수비를 지속적으로 측정할 수 있는 점에서 비파괴 모니터링 기술로 구분할 수 있다. 체적함수비와 유전율상수의 관계에서 측정센서의 로드길이에 따른 측정오차는 다소 파악되나, 이들의 관계로부터 Topp et al.(1980) 교정곡선과 비교하여 표준사에 대한 1차원 관계식과 관계곡선을 유도할 수 있었다. 결론적으로 제안된 FDR system과 측정센서로부터 측정된 측정결과들은 Topp et al.(1980) 교정곡선과 매우 흡사한 형태를 보여준다. The authors designed a new technique to measure dielectric constant of a soil media by Frequency Domain Reflectometry (FDR) system and its measurement sensor probe with different length such as 7cm, 10cm and 15cm for estimating the variations of dielectric constant. Measurement of dielectric constant of soil material is possible to measure an interference wave generated by between incidence wave and reflection wave which are detected to electro-magnetic wave through the directional coupler at the high frequency range, 0.1 to 1.7GHz, by FDR system. The obtained experimental results verified that the technique is very promising for non-destructive and continuous soil volumetric water content measurement monitoring in a laboratory. The relationship between the soil volumetric water content and the dielectric constant of soil media (standard sand) was expressed by a single regression curve independent of soil texture at a small experimental error. Also the derived regression curve coincided well with that obtained by Topp curve.

      • 국내 사방댐 제도와 관리시스템 개선방안 연구

        김만일(Kim, Man-Il),이문세(Lee, Moon-Se),장범수(Chang, Buhm-Soo) 한국구조물진단유지관리학회 2011 한국구조물진단학회 학술발표회논문집 Vol.15 No.1

        This study conducted to estimate institutional standards and maintenance realities of the debris facilities. In order to solve the problem of the debris facilities, it was suggested to four kinds of the results through the research that countermeasure and consideration of various problems for maintenance and management system improvements of the debris barrier based on the investigation data. Firstly, a check list of debris barrier needs to an establishment of various criteria because the cost and criteria for construction and maintenance of its facilities are obscurities. Secondly, supervision qualification system needs to empowerment a supervision requirement of debris facilities considered the supervision duty. Thirdly, maintenance manual or criteria needs to efficient management of the debris barrier. Finally, standardized completion sign needs to integrated management of debris facilities around the constructed its facilities.

      • KCI등재

        현장 모니터링 적용을 위한 풍화토와 함수비센서의 접촉체적에 따른 지반물성 연구

        김만일 ( Man Il Kim ),채병곤 ( Byung Gon Chae ) 대한지질공학회 2008 지질공학 Vol.18 No.3

        주파수 인피던스를 이용하는 ThetaProbe ML2x인 ADR 형식의 토양함수비센서를 적용하여 주문진 표준사, 상주 화강풍화토, 장수 편마암풍화토을 대상으로 실험을 수행하였다. 시험의 목적은 측정센서의 측정 정밀도를 측정로드부 삽입 깊이에 따른 변화 양상을 파악하였다. 흙매질은 체적함수비 함량과의 관계를 비교하기 위하여 건조상태와 습윤상태로 구분하여 수행하였다. 측정결과에서 측정로드부가 흙매질 내 5 cm 이상 삽입되면 측정전압의 변화폭이 크게 감소하는 것을 파악하였다. 또한, 표준사와 같이 균질한 입자를 가진 흙보다는 점토와 실트 등과 같은 세립질을 함유한 화강풍화토와 편마암풍화토에서 측정전압이 안정적인 형태를 갖는 것으로 나타났다. 따라서, 측정치는 측정로드부가 다공질매질과의 접촉 면적이 커질수록 안정적인 값을 제공한다. Evaluation of an amplitude domain reflectometry (ADR) type soil moisture sensor as ThetaProbe ML2x using the response of frequency impedance was performed in a variety of soil porous media such as Jumunjin standard sand, weathered granite soil at Sangju area, and weathered gneiss soil at Jangsu area. The tested soils were classified with a dried condition and a wetted condition for comparing with soil volumetric water content under different installed depths of the measurement sensor. In the results the part of measurement rod including one signal rod and three shield rod 6 cm in length was found to decrease the variation of measurement output voltage with insert 5 cm over into the soil porous media. The measurement output voltage was verified to more stable output voltage under weathered granite soils and weathered gneiss soils contained the fine grain materials such as clay and silt minerals than the gradual grain material like as the standard sands. Therefore, measurement values by soil moisture sensor can be offered the more stable values when an contact volume between soil porous media and measurement sensor increase.

      • KCI등재

        석조문화재 기초지반 파악을 위한 모형지반에서의 탐사기법 적용

        김만일 ( Man Il Kim ),이창주 ( Chang Joo Lee ),종태 ( Jong Tae Kim ),지수 ( Ji Soo Kim ),사덕 ( Sa Dug Kim ),정교철 ( Gyo Cheol Jeong ) 대한지질공학회 2008 지질공학 Vol.18 No.4

        지표 근접 지질조사 및 매설물 조사에 응용되는 GPR탐사를 통해 석조문화재 기초지반을 효과적으로 탐지하기 위해 토양층과 자갈층이 교호하는 지질공학적인 모형지반(천부 지층구조)을 3 m의 깊이로 재건하여 GPR탐사 및 탄성파 굴절법 탐사를 측선별로 수행하였다. GPR탐사에 사용되는 주파수를 다양하게 적용하여 주파수별 분해능에 따른 모형지반의 경계구분을 확인하였다. 그 결과 100 MHz의 주파수 대역에서 분해능은 낮지만 가장 효과적으로 지층경계를 구분할 수 있었으며, 225 MHz, 450 MHz, 900 MHz의 고주파수 대역을 사용한 결과에서는 전자파의 감쇠로 인해 하부경계를 구분할 수 없었으나 천부의 분해능은 향상되었다. 이로부터 심부에 대한 100 MHz의 자료와 천부에 대한 고주파수 단면도를 조합하여 최종단면도를 얻었다. 탄성파 굴절법 탐사에서는 모형지반의 정확한 경계 및 지층 간 경계면은 파악할 수 없었으나, 모형지반이 위치하고 있는 구간에서의 등속도선이 주변 지역에 비해 상대적으로 깊은 심도까지 분포하는 것으로 볼 때 원지반과 모형 경계의 속도 대비를 파악할 수 있는 것으로 나타났다. To effectively delineate the foundation of stone relics by GPR and seismic refraction methods, a geological engineering model was constructed with alternating layer of soil and gravel to a depth of 3 m. This study was aimed at mapping the boundaries of model ground structure and interfaces of alternating layer using the various frequency antenna in GPR survey and seismic velocities. Compared to the resolution from the high frequency antenna, the image resolution from the survey using 100 Hz antenna is the lower, but with the deeper image coverage. On the contrast, the deeper structure was not mapped in the higher frequency data due to higher absorption effect, but the shallow layered zone was distinctively resolved. Therefore subsurface images were effectively provided by integrating the data with 100 MHz and 450 MHz antennas for the deep and shallow structures, respectively. Regarding the seismic refraction data, the boundaries of the model and interface of the alternating layers were not successfully mapped due to the limit of the survey length. However, the equivalent contours of low velocity extended deep as considerable velocity contrasts with surrounding ground.

      연관 검색어 추천

      이 검색어로 많이 본 자료

      활용도 높은 자료

      해외이동버튼