http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
성지수,Kim Hoon,Park Wan Beom,Kim Nam Joong,Oh Myoung-don,Park Sung Sup,박중신,최영민 대한의학회 2020 Journal of Korean medical science Vol.35 No.25
With highly active antiretroviral therapy, human immunodeficiency virus (HIV) infection is considered to be a manageable chronic disease. The improved prognosis increases the desire of individuals with HIV to have biological offspring. With the establishment of washing protocol, no HIV transmission has been reported among more than 11,000 assisted reproduction technology (ART) cycles. Although the Acquired Immunodeficiency Syndrome Prevention Act in Korea prevents the use of HIV-infected blood, organs, tissues and semen, we recently obtained the authentic approval from the Korea Centers for Disease Control and Prevention for the practice of ART in HIV-serodiscordant couples. We report a 32-year-old HIV-seronegative female with her husband who was HIV-1 seropositive. After semen washing was performed by means of a density gradient and the swim-up technique, HIV-1 ribonucleic acid was not detected in the semen. An aliquot of processed semen was cryopreserved before ART. None of 3 cycles of intrauterine insemination was successful. After the third frozen-thawed embryo transfer following two cycles of intracytoplasmic sperm injection, an intrauterine singleton pregnancy was identified. She gave birth to a normal healthy male baby at full term by Cesarean section. She and her baby were tested for HIV during pregnancy and after delivery and the results were negative. Semen washing may be a safe ART method for HIV-serodiscordant couples who desire to have a baby in Korea.
대구지역 의료기관의 CT, MRI 보유 현황과 정도관리에 관한 담당 방사선사들의 인식 조사
이창석,조인성,이상욱,정석종,성아라,이현정,형미림,성지수,박창희,Lee, Chang-Suk,Jo, In-Seong,Lee, Sang-Uk,Jeong, Seok-Jong,Sung, A-Ra,Lee, Hyun-Jung,Hyung, Mi-Rim,Seong, Ji-Su,Park, Chang-Hee 대한디지털의료영상학회 2011 대한디지털의료영상학회논문지 Vol.13 No.3
This study concerns the present possession of CT and MRI machines in Daegu and the technologists' awareness of Quality Control. the study was conducted by visiting forty medical institutions as well as a survey. The survey was carried out by technologists responsible for CT and MRI. CT and MRI machines have only been used in medical institutions in Daegu for a short period. The study revealed that most of them have been acquired by those institutions recently. Most of the technologists who participated in the study are aware of the (prescribed) Quality Control measures and conduct regular inspections in accordance with the quality control chart, however some of them do not.