이희발 대한신장학회 1983 Kidney Research and Clinical Practice Vol.2 No.2
Continuous ambulatory peritoneal dialysis(CAPD) is a r,ew and Increasingly used form of maintenance dialysis therapy here in Korea as well as in the rest of the world. High dropout rates and frequent hos- pitalizations are due mainly to peritonitis and other dialysis-related complications. Socioeconomic factor is. Another reason for high dropout rates in Korea. It is hoped that improved technology and increasing experience will reduce the incidence of peritonitis and dropout rates. Further reduction of costs of CAPD and expansion of health insurance coverage will also- help reduce dropout rates.
미세기포 조영제를 이용한 하모닉 초음파 신관류 영상: 예비 조사
이희발,최득린,Lee, Hui-Bal,Choe, Deuk-Rin 대한영상의학회 2003 대한영상의학회지 Vol.49 No.2
목적:신이식후 신관류 상태의 평가에 있어서 미세기포 조영제를 이용한 하모닉 초음파로 신관류 영상을 얻을 수 있는지와 정상 관류 범위를 $^{99m}$Tc-DTPA 신관류 영상과 비교하여 알아보고자 하였다. 대상과 방법:6개월 동안 신이식술을 시행한 환자 중 $^{99m}$Tc-DTPA 신관류 영상과 미세기포 조영제를 이용한 하모닉 초음파 신관류 영상을 모두 시행한 30명을 대상으로 하였다.초음파 영상은 미세기포 조영제 Levovist $^{TM}$(SH U 508A;Schering AG,Berlin,Germany)를 주사한 후 3분까지 3초마다 영상을 얻었다.초음파 신관류 영상은 분석 프로그램을 이용하여 신관류 영상곡선으로 전환한 후 $^{99m}$Tc-DTPA 신관류 영상 곡선의 최고점에 이르는 시간 (T $_{peak}$ )과 비교하였다. 결과:$^{99m}$Tc-DTPA 신관류 영상곡선의 T$_{peak}$ 는 정상군에서 평균 16.2초,비정상군에서 평균 39.6초였으며,미세기포 조영제를 이용한 하모닉 초음파 신관류 영상곡선의 T peak 는 정상군에서 평균 23.7초,비정상군에서 평균 46.2초였다. $^{99m}$Tc-DTPA를 이용한 신관류 곡선과 비교하여 미세기포 조영제를 이용한 하모닉 초음파 신관류 영상곡선의 T $_{peak}$ 값은 좋은 상관관계를 보였다 (상관계수=0.8209,p=0.0001).또한 미세기포 조영제를 이용한 하모닉 초음파 신관류영상곡선의 최적의 정상 T$_{peak}$값은 35초가 진단적 효율이 가장 높은 것으로 나타났다 (민감도=90%, 특이도=95%). 결론:신이식 환자에서 미세기포 조영제를 이용한 하모닉 초음파 신관류 영상은 $^{99m}$Tc-DTPA를 이용한 신관류 영상과 유사한 결과를 얻을 수 있으며,최적의 정상 T $_{peak}$값은 35초였다. Purpose: To compare, in terms of their feasibility and normal range, $^{99m}$Tc-DTPA renal perfusion imaging and renal perfusion imaging using harmonic ultrasound (US)with a microbubble contrast agent for the evaluation of renal perfusion after renal transplantation. Materials and Methods: During a six-month period, thirty patients who had received a renal transplant underwent both $^{99m}$Tc-DTPA renal perfusion imaging and renal perfusion imaging using harmonic US with a microbubble contrast agent. Sonographic renal perfusion images were obtained before and after a bolus injection of the microbubble contrast agent Levovist$^{TM} (SH U 508A; Schering AG, Berlin, Germany) every 3 seconds for 3 minutes. Sonographic renal perfusion images were converted into a renal perfusion curve by a computer program and Tpeak of the curve thus obtained was compared with that of the $^{99m}$Tc-DTPA curve. Results: Average T$_{peak}$ of the $^{99m}$Tc-DTPA renal perfusion curve was 16.2 seconds in the normal group and 39.6 seconds in the delayed perfusion group, while average T$_{peak}$ of the sonographic renal perfusion curve was 23.7 seconds and 46.2 seconds, respectively. T$_{peak}$ of the sonographic renal perfusion curve showed a good correlation with that of the $^{99m}$Tc-DTPA curve (correlation coefficient=0.8209; p=0.0001). The cut-off value of T$_{peak}$ of the sonographic renal perfusion curve was 35 seconds (sensitivity=90%, specificity=95%). Conclusion: In patients who have received a renal transplant, the findings of renal perfusion imaging using harmonic US with a microbubble contrast agent show close correlation with those of $^{99m}$Tc-DTPA renal perfusion imaging. The optimal cut-off value of Tpeak of the sonographic renal perfusion curve was 35 seconds