http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
Novel and facile criterion to assess the accuracy of WSS estimation by 4D flow MRI
Ko, Seungbin,Yang, Byungkuen,Cho, Jee-Hyun,Lee, Jeesoo,Song, Simon Elsevier 2019 Medical image analysis Vol.53 No.-
<P><B>Abstract</B></P> <P>Four-dimensional flow magnetic resonance imaging (4D flow MRI) is a versatile tool to obtain hemodynamic information and anatomic information simultaneously. The wall shear stress (WSS), a force exerted on a vessel wall in parallel, is one of the hemodynamic parameters available with 4D flow MRI and is thought to play an important role in clinical applications such as assessing the development of atherosclerosis. Nevertheless, the accuracy of WSS obtained with 4D flow MRI is rarely evaluated or reported in literature, especially in the in vivo studies. We propose a novel and facile criterion called Reynolds resolution to assess the accuracy of WSS estimation in 4D flow MRI studies. Reynolds resolution consists of a spatial resolution, encoding velocity, kinematic viscosity of a working fluid, and signal-to-noise ratio, which are readily accessible information in 4D flow MRI measurements. We explored the relationship between Reynolds resolution and the WSS error. To include diverse and extensive cases, we measured three circular tubing flows with a diameter of 40, 8, and 2 mm. The 40 mm tubing flow was measured by 3 Tesla (T) human MR scanner with a knee coil and spatial resolution of 0.5 mm. The 8 and 2 mm tubing flows were both measured by 4.7 T MR scanner, but the scans were performed with a conventional birdcage coil (8 mm tubing) and a custom-made solenoid coil (2 mm tubing), respectively. The spatial resolution was varied from 0.2, 0.4 or 0.8 mm for the 8 mm tubing flow, but was fixed at 0.090 mm for 2 mm tubing flow. In addition, the near-wall velocity gradient, required to be determined prior to the WSS, was calculated using two methods; these included assuming a linear velocity profile or quadratic velocity profile near wall. The accuracy of WSS obtained using each method and tubing flow was evaluated against the theoretical WSS value. As a result, we found that Reynolds resolution is in logarithmic relation to the WSS error.</P> <P><B>Highlight</B></P> <P> <UL> <LI> Reynolds resolution (RR) is portrayed as a novel criterion to assess WSS accuracy. </LI> <LI> A WSS error is approximated with RR though a true WSS is unknown. </LI> <LI> RR is calculated arithmetically with 4D flow MRI setting parameters. </LI> </UL> </P> <P><B>Graphical abstract</B></P> <P>[DISPLAY OMISSION]</P>
차량 시트백 결합형 복사식 면상발열 난방 장치 컨셉 개발
정승빈(Seungbin Jeong),김동윤(Dongyoon Kim),이지연(Jiyeon Lee),김성준(Sung Jun Kim),오만주(Manju Oh),정소라(Sola Chung),양현규(Hyeonkyu Yang),이희승(Hui Sung Lee) 한국자동차공학회 2022 한국자동차공학회 학술대회 및 전시회 Vol.2022 No.11
전기자동차 사용 인구가 많아짐에 따라 전기자동차가 가지는 문제에 대한 시장의 해결 요구가 높아지고 있다. 특히 저온 환경에서 배터리 저감 속도가 가속화되는 것이 주요 문제 중 하나이다. 차량 실내 난방을 위한 전기 에너지 사용은 배터리 저감 문제를 더욱 심화시킨다. 그래서 본 논문은 에너지 사용량이 낮은 복사식 면상발열체를 활용한 난방 장치의 사용성을 높여, 전기자동차의 배터리 저감을 완화시키는 방안을 연구하고 이를 적용한 장치의 컨셉을 개발하였다. 세부적으로는 난방 장치에 위치 조절과 거리 조절 기능을 부여하였다. 사용자의 다양한 체형에 대한 대응력을 높임으로 체감 난방 만족도를 증대시키고자 하였다. 또한 기존 제품 대비 난방 부위인 허벅지의 더 넓은 면적을 커버할 수 있음을 프로토타이핑을 통해 확인하였다.
스마트폰 환경에서 행동 데이터 기반 모바일 친밀도 모델 개발
임승빈(Seungbin Yim),김상민(Sangmin Kim),홍진의(Jineui Hong),양다슬(Daseul Yang),이성일(Seongil Lee) 한국HCI학회 2017 한국HCI학회 학술대회 Vol.2017 No.2
본 연구에서는 스마트 어플리케이션을 기반으로 모바일 친밀도 모델을 세우는 것을 목표로 한다. 모바일 친밀도 정의를 위해서 고려한 친밀도 요소는 자기노출(Self-Disclosure), 상호작용 빈도(Frequency) 그리고 기간(Duration)이다. 위의 3 가지 요소는 모바일 환경에 맞게 변형하여 모바일 친밀도의 기준으로 삼는다. 상호작용의 빈도는 SNS 기반의 어플리케이션 사용 횟수를 통해 변수화되며, 기간은 어플리케이션을 통한 상호교류 기간 및 행동의 주기를 통해 변수화 된다. 자기노출의 경우, 스마트폰에서 제공되는 기능 및 서비스들과 자기노출을 연계하여 AHP 를 통해 정량적인 설문 평가를 진행한다. 모바일 친밀도에 대한 결과는 20~30 대와 40~50 대의 각 두 집단에 대하여 도출한다. 친밀도 측정 모델은 두 개의 나이 집단에 따라 30 명씩을 대상으로, 실제로 모바일 친밀도를 적용한 실험을 통해 모바일 친밀도를 얻고 이것을 피실험자들이 생각하는 주관적 친밀도와 비교 분석하여 그 결과를 통해 본 연구의 모바일 친밀도 모델을 검증하였다. 20 대~30 대에 적용되는 모바일 친밀도는 적당한 상관관계를 보였으며 40 대~50 대에 적용되는 모바일 친밀도는 강한 상관관계를 보였다. 각 집단의 모바일 친밀도의 정확도는 전자의 집단에 대해서는 83.3%, 후자의 집단에서는 90.0%를 보였다.
Single layer retarder with negative dispersion of birefringence and wide field-of-view
Hwang, Jiyong,Yang, Seungbin,Choi, Yu-Jin,Lee, Yumin,Jeong, Kwang-Un,Lee, Ji-Hoon The Optical Society 2016 Optics express Vol.24 No.17
<P>A single layer retarder possessing negative dispersion (ND) of birefringence as well as wide field-of-view (FOV) was long-term objective in optical science. We synthesized new guest reactive monomers with x-shape and mixed them with the host smectic reactive mesogen. The host-guest molecules formed two dimensionally self-organized nanostructure and showed both the ND of birefringence and wide FOV properties. We simulated the antireflection property of a circular polarizer using the optical properties of the retarder. The average reflectance of the retarder was 0.52% which was much smaller than that of the commercial single layer ND retarder 1.83%. (C) 2016 Optical Society of America</P>
Lee, Hyojin,Yang, Seungbin,Lee, Ji-Hoon Elsevier 2015 CURRENT APPLIED PHYSICS Vol.15 No.4
<P><B>Abstract</B></P> <P>Two-dimensionally self-organized smectic liquid crystal (LC)-polymer composite has been reported to show a negative dispersion of birefringence [H. Lee and J.-H. Lee, Opt. Lett. 39, 5146 (2014)]. In this paper, we separately measured the extraordinary and ordinary refractive indices n<SUB>e</SUB> and n<SUB>o</SUB> of the pure LC and LC-polymer composite and simulated the dependence of the transmittance and the color on the viewing angle for the display application. The LC-polymer composite with the negative dispersion property showed a wider viewing angle and a smaller color shift compared to the pure liquid crystal with a positive dispersion of birefringence.</P> <P><B>Highlights</B></P> <P> <UL> <LI> The extraordinary and ordinary refractive indices n<SUB>e</SUB> and n<SUB>o</SUB> of the pure liquid crystal and liquid crystal-polymer composite were measured. </LI> <LI> The dependence of the transmittance and the color shift on the viewing angle were simulated. </LI> <LI> The liquid crystal-polymer composite with negative dispersion of birefringence showed wider viewing angle and smaller color shift. </LI> </UL> </P>
New Virtual Frisch-Grid CdZnTe Detector Design With Sub-Millimeter Spatial Resolution
Kisung Lee,Bolotnikov, Aleksey,Seungbin Bae,Roy, Utpal,Camarda, Giuseppe,Petryk, Matthew,Yonggang Cui,Hossain, Anwar,Ge Yang,Dedic, Vaclav,Kihyun Kim,James, Ralph B. Professional Technical Group on Nuclear Science 2014 IEEE transactions on nuclear science Vol.61 No.5
<P>We evaluated the performance of a position-sensitive virtual Frisch-grid (VFG) CdZnTe detector, 6 mm ×6 mm ×15 mm, via sensing strips on its side surfaces. Once the signals were collected from the anode, and from four or eight strips attached to the detector's sides, we assessed the anode's energy spectra and derived histograms from the side electrodes to evaluate the feasibility of achieving sub-millimeter spatial resolution in the X-Y plane. Using a highly collimated 30-keV X-ray beam at the National Synchrotron Light Source, and applying corrections to the raw data, we determined the photon-interaction points by conventional Anger logic and via a more sophisticated statistics-based positioning (SBP) algorithm. With the VFG detector's current configuration, we achieved a resolution below 1 mm, even for low-energy X-rays.</P>
김현아(Hyuna Kim),문승빈(Seungbin Moon),양동원(Dongwon Yang) 표준인증안전학회 2012 표준인증안전학회지 Vol.2 No.2
본 논문에서는 차세대 성장 동력으로 발전하고 있는 로봇 분야의 국내 표준화 현황을 소개하고자 한다 로봇분야 국내 표준화 활동의 . 대표적인 기구는 2005년에 설립된 “지능형로봇 표준 포럼”으로, 이를 통하여 산학연이 중심이 되어 포럼 표준(KOROS 표준)을 개발하여 오고 있다. 현재 약 80여건의 표준을 제정한 바 있으며, 이중에서 15건은 KS 국가 표준으로 제정된 바 있다. 또한, 이러한 표준 활동을 바탕으로 2009년부터는 품질인증 제도와 연계하여, 지능형로봇 품질인증 제도를 또한 운영하고 있다. 현재 청소로봇 및 교구로봇에 대한 인증이 진행중이며, 향후에 교육보조로봇, 안내로봇, 오락로봇 등의 인증을 준비중에 있다. 특히, 청소로봇 인증의 결과로 국내 청소로봇 제품이 세계시장에서 가장 앞선 기술로 평가되고 있다.
자기공명유속계를 이용하여 예측한 벽면전단응력의 정확도 평가 기준 개발
이지수(Jeesoo Lee),고승빈(Seungbin Ko),양병권(Byungkuen Yang),조지현(Jee-Hyun Cho),송시몬(Simon Song) 대한기계학회 2018 대한기계학회 춘추학술대회 Vol.2018 No.12
Wall shear stress (WSS) exerted on a blood is one of the key factors associated with cardiovascular diseases. It has been found that magnitude and temporal oscillation of WSS can be correlated with atherosclerosis, aortic dilatation and vascular remodeling. Magnetic resonance velocimetry (MRV) is currently the most advanced technique that can noninvasively estimate temporal and volumetric distribution WSS in vivo. Numerous clinical studies have been reported which determined WSS in various vascular region based on MRV measurements. However, it is difficult to discover the descriptions about the absolute accuracy of WSS in literatures, especially in clinical studies because the true value of WSS is unknown. Therefore, a facile criterion for assessing the accuracy of estimated WSS for MRV measurements with unknown WSS would be valuable. In this research, we propose a novel criterion called Reynolds resolution to assess the absolute accuracy of WSS estimated from MRV data. It is described with measurement parameters and thus, can readily be calculated. We investigated the relation between the Reynolds resolution and WSS accuracy by measuring pressuredriven laminar circular tubing flows and a proportional relation was found indicating that the Reynolds resolution could have its potential to be used for predicting the absolute errors of MRV-estimated WSS.