RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      검색결과 좁혀 보기

      선택해제
      • 좁혀본 항목 보기순서

        • 원문유무
        • 원문제공처
          펼치기
        • 등재정보
        • 학술지명
          펼치기
        • 주제분류
        • 발행연도
          펼치기
        • 작성언어
        • 저자
          펼치기

      오늘 본 자료

      • 오늘 본 자료가 없습니다.
      더보기
      • 무료
      • 기관 내 무료
      • 유료
      • KCI등재

        국내에서 유통되는 활성탄을 이용한 벤젠, 톨루엔, 아세톤 및 노말 헥산의 등온흡착용량 평가 연구

        이나루 ( Naroo Lee ),이광용 ( Gwang Yong Yi ),박두용 ( Dooyong Park ) 한국산업보건학회 2014 한국산업보건학회지 Vol.24 No.2

        Objectives: To develop domestic charcoal tubes with good adsorption capacity, breakthrough experiments were performed on four types of activated charcoal. Materials: The adsorption capacity and the adsorption rate were determined using a modified Wheeler equation after the breakthrough experiment. For four types of charcoal (J, K, S and SKC Inc. 226-01), 100 ㎎ were used in the breakthrough experiment. The test was done on benzene, toluene, n-hexane, and acetone in a dynamic chamber. Results: K charcoal had the greatest surface area and the highest micropore volume. J charcoal had a similar surface area and micropore volume to SKC charcoal. S charcoal had the lowest surface area and micropore volume. J charcoal had the highest adsorption capacity at 101, 252 and 609 ppm of benzene. The gap in benzene adsorption capacity among the types of charcoal was the least at 609 ppm and the greatest at 101 ppm. J charcoal showed the highest adsorption capacity at 54, 106, 228 and 508 ppm of toluene. J charcoal and SKC charcoal had a similar adsorption capacity for acetone. J charcoal had the highest adsorption capacity for n-hexane. In the experiment featuring 10% breakthrough volume, 10% breakthrough occurred at 18 liters at 2065.9 ㎎/㎥ for J charcoal and at 20 liters at 1771.2 ㎎/㎥ for K charcoal. It was difficult to judge adsorption capacity by surface area and micropore volume of charcoal. J charcoal, which was similar to SKC charcoal in surface area and micropore volume, showed good adsorption capacity at common workplace concentrations. Conclusions: The adsorption capacity of J and K charcoal was superior compared with SKC charcoal. J and K charcoal can be considered appropriate for use as sampling media based on this result.

      • KCI등재

        볼텍스쉐이커를 이용한 11개 나노물질의 분진날림 비교

        이나루 ( Naroo Lee ),박진우 ( Jinwoo Park ) 한국산업보건학회 (구 한국산업위생학회) 2018 한국산업보건학회지 Vol.28 No.3

        Objectives: Dustiness of nanomaterials is considered as exposure index of essential material. Research on dustiness of nanomaterial is needed to control exposure in workplaces. Method: Dustiness measurement using vortex shaker were installed in the laboratory. Nanomaterials, 1 g, was put in the glass test tube and shaked using vortex shaker. Aerosol dispersed was measured using scanning mobility particle sizer(SMPS) and optical particle counter(OPC). Mass concentration using PVC filter and cassette was measured and TEM grid sampling was conducted. Total particle concentration and size distribution were calculated. Image and chemical composition of particles in the air were observed using transmission electron microscopy and energy dispersive X-ray spectrometer. Eleven different test nanomaterials were used in the study. Results: Rank of mass concentration and particle number concentration were coincided in most cases. Rank of nanomateirals with low concentration were not coincided. Two types of fumed silica had the highest mass concentration and particle number concentration. Indium tin oxide, a mixture of indium oxide and tin oxide, had high mass concentration and particle number concentration. Indium oxide had very low mass concentration and particle number concentration. Agglomeration of nanoparticles in the air were observed in TEM analysis and size distribution. In this study, mass concentration and particle number concentration were coincided and two index can be used together. The range of dustiness in particle number concentration were too wide to measure in one method. Conclusion: Particle number concentration ranged from low concentration to high concentration depend on type of nanomaterial, and varied by preparation and amount of nanomaterial used. Further study is needed to measure dustiness of all nanomaterial as one reference method.

      • KCI등재

        버스 정비 작업자에 대한 석면 및 디젤 엔진 배출물질 노출 평가

        이나루 ( Naroo Lee ),이광용 ( Gwangyong Yi ) 한국산업보건학회 (구 한국산업위생학회) 2016 한국산업보건학회지 Vol.26 No.2

        Objectives: Lung cancer occurred with worker working in an urban bus garage. A survey was conducted to investigate whether lung cancer had causal relationship with work. Exposure to asbestos and diesel engine exhaust were suspected. Methods: Airborne asbestos was sampled on membrane filter and analyzed using phase-contrast microscopy. Airborne diesel exhaust was sampled using quartz filter and analyzed with thermal-optical analyzer. Polynuclear aromatic hydrocarbons was sampled using PTFE filter and XAD-2 tube and analyzed with gas chromatography-mass selective detector. Results: Airborne asbestos concentration was under 0.01 fiber/cc. Worker who warmed up an engine of urban bus for 2 hours was exposed to elemental carbon concentration, 15.5㎍/㎥. Only naphtalene among polynuclear aromatic hydrocarbons was detected. Conclusions: It was difficult to conclude about worker exposure to asbestos because working hour related asbestos was too short. In reviewing papers, the exposure to asbestos over 0.01 fiber/cc during exchange brake lining was found. It was identified that worker``s occupational exposure to diesel exhaust based on elemental carbon was higher than the other occupational exposure to diesel exhaust

      • KCI등재

        작업공정 및 활동에 따른 국내 작업장 납 노출특성 평가

        이도희 ( Dohee Lee ),이나루 ( Naroo Lee ) 한국산업보건학회 2023 한국산업보건학회지 Vol.33 No.1

        Objectives: The purpose of this study is to systematically identify situations where exposure levels are expected to be high by structuring domestic lead measurement data according to exposure processes and activities. Methods: Occupational exposure data on lead was collected from the results of the Evaluation of Reliability of Working Environment Measurement conducted by the government from 2019 to 2020. Lead exposure characteristics were analyzed by PROC (process category) and activity. The Risk Characterization Ratios (RCRs) of five PROCs according to ventilation type and lead content were evaluated using the MEASE (Metal's EASE) model. Results: The exposure data on lead (n=250) was classified into 12 PROCs and 12 activities, with an average concentration of 0.040 mg/㎥ and about 14% exceeding the occupational exposure limit of 0.05 mg/㎥. Processes with high exposure levels were PROC 7 (industrial spraying), 23 (open processing and transfer operations of molten metal), 24 (mechanical treatment), 25 (welding), and 26 (handling of powder containing lead). The results of evaluating RCR for the five PROCs were greater than 1 or close to 1 even if local exhaust ventilation was used. Conclusions: There is a possibility that the concentration of exposure is high in the casting and tapping of molten metal containing lead, mechanical treatment such as fracturing and abrasion, handling of powder, spraying, battery manufacturing, and waste battery recycling processes. It is necessary to implement chemical management policies for workplaces with such processes.

      • SCOPUSKCI등재

        Comparison of Real Time Nanoparticle Monitoring Instruments in the Workplaces

        Ham, Seunghon,Lee, Naroo,Eom, Igchun,Lee, Byoungcheun,Tsai, Perng-Jy,Lee, Kiyoung,Yoon, Chungsik Occupational Safety and Health Research Institute 2016 Safety and health at work Vol.7 No.4

        Background: Relationships among portable scanning mobility particle sizer (P-SMPS), condensation particle counter (CPC), and surface area monitor (SAM), which are different metric measurement devices, were investigated, and two widely used research grade (RG)-SMPSs were compared to harmonize the measurement protocols. Methods: Pearson correlation analysis was performed to compare the relation between P-SMPS, CPC, and SAM and two common RG-SMPS. Results: For laboratory and engineered nanoparticle (ENP) workplaces, correlation among devices showed good relationships. Correlation among devices was fair in unintended nanoparticle (UNP)-emitting workplaces. This is partly explained by the fact that shape of particles was not spherical, although calibration of sampling instruments was performed using spherical particles and the concentration was very high at the UNP workplaces to allow them to aggregate more easily. Chain-like particles were found by scanning electron microscope in UNP workplaces. The CPC or SAM could be used as an alternative instrument instead of SMPS at the ENP-handling workplaces. At the UNP workplaces, where concentration is high, real-time instruments should be used with caution. There are significant differences between the two SMPSs tested. TSI SMPS showed about 20% higher concentration than the Grimm SMPS in all workplaces. Conclusions: For nanoparticle measurement, CPC and SAM might be useful to find source of emission at laboratory and ENP workplaces instead of P-SMPS in the first stage. An SMPS is required to measure with high accuracy. Caution is necessary when comparing data from different nanoparticle measurement devices and RG-SMPSs.

      • Comparison of data analysis procedures for real-time nanoparticle sampling data using classical regression and ARIMA models

        Ham, Seunghon,Kim, Sunju,Lee, Naroo,Kim, Pilje,Eom, Igchun,Lee, Byoungcheun,Tsai, Perng-Jy,Lee, Kiyoung,Yoon, Chungsik Informa UK (TaylorFrancis) 2017 Journal of applied statistics Vol.44 No.4

        <P>Real-time monitoring is necessary for nanoparticle exposure assessment to characterize the exposure profile, but the data produced are autocorrelated. This study was conducted to compare three statistical methods used to analyze data, which constitute autocorrelated time series, and to investigate the effect of averaging time on the reduction of the autocorrelation using field data. First-order autoregressive (AR(1)) and autoregressive-integrated moving average (ARIMA) models are alternative methods that remove autocorrelation. The classical regression method was compared with AR(1) and ARIMA. Three data sets were used. Scanning mobility particle sizer data were used. We compared the results of regression, AR(1), and ARIMA with averaging times of 1, 5, and 10min. AR(1) and ARIMA models had similar capacities to adjust autocorrelation of real-time data. Because of the non-stationary of real-time monitoring data, the ARIMA was more appropriate. When using the AR(1), transformation into stationary data was necessary. There was no difference with a longer averaging time. This study suggests that the ARIMA model could be used to process real-time monitoring data especially for non-stationary data, and averaging time setting is flexible depending on the data interval required to capture the effects of processes for occupational and environmental nano measurements.</P>

      연관 검색어 추천

      이 검색어로 많이 본 자료

      활용도 높은 자료

      해외이동버튼