전력계통의 중성선에 적용된 초전도한류기의 대칭고장전류 저감방안 분석
임성훈,Lim, Sung-Hun 한국전기전자재료학회 2010 전기전자재료학회논문지 Vol.23 No.2
The superconducting fault current limiter (SFCL) applied into the neural line of a power system, which can limit the unsymmetrical fault current from the single-line ground fault or the double-line ground fault, was reported to be the effective application location of the SFCL in a power system. However, the limiting operation for the symmetrical fault current like the triple line-ground fault is not effective because of properties of the balanced three-phase system. In this paper, the limiting method of the symmetrical fault current in a power system with a SFCL applied into neutral line was suggested. Through the short-circuit experiments of the three-phase fault types for the suggested method, the fault current limiting and recovery characteristics of the SFCL in the neutral line were analyzed and the effectiveness of the suggested method was described.
임성훈,Lim, Sung-Hun 한국전기전자재료학회 2010 전기전자재료학회논문지 Vol.23 No.2
The transformer is expected to be an essential component of a superconducting fault current limiter (SFCL) for both the increase of its voltage ratings and the simultaneous quench due to different critical current between high-$T_C$ superconducting (HTSC) elements comprising the SFCL. However, in order to perform the effective current limiting operation of the SFCL, the design for the SFCL considering the hysteresis characteristics of the iron core is required. In this paper, the influence of the hysteresis characteristics of the iron core comprising the transformer type SFCL on its current limiting characteristics was investigated. Through the comparative analysis on the hysteresis curves due to the ratio of the turn number between the 1st and the 2nd windings of the transformer, the proper design condition for the ratio of the turn number to achieve the effective current limiting operation of the transformer type SFCL could be obtained.
병렬연결된 두 코일의 자기결합을 이용한 초전도 전류제한기의 전류제한 및 전압강하 보상 특성 분석
임성훈,Lim, Sung-Hun 한국전기전자재료학회 2010 전기전자재료학회논문지 Vol.23 No.2
The superconducting fault current limiter (SFCL) plays a role in compensating the voltage sag of the sound feeder adjacent to the fault feeder as well as the fault current limiting operation of the fault feeder. Especially, the SFCL using magnetic coupling of two coils with parallel connection has different voltage sag compensating and current limiting characteristics due to the winding direction and the inductance ratio of two coils. In this paper, the current limiting and the voltage sag compensating characteristics of a SFCL using magnetic coupling of parallel connected two coils were analyzed. Through the analysis on the experimental results considering the winding direction of two coils, the SFCL designed with the additive polarity winding was shown to have the higher limited fault current than the SFCL designed with the subtractive polarity winding. In addition, it could be confirmed that the higher fault current limitation of the SFCL could be contributed to the higher load voltage sag compensation.
두 개의 자기경로 철심을 갖는 코일의 자기결합을 이용한 초전도 전류제한기의 히스테리시스 특성
임성훈,Lim, Sung-Hun 한국전기전자재료학회 2009 전기전자재료학회논문지 Vol.22 No.12
The iron core, which comprises the superconducting fault current limiter (SFCL) using magnetic coupling of coils, can be operated in the saturation region, especially at the initial fault period. This operation of the iron core in the saturation region deteriorates the fault current limiting operation of the SFCL. To solve the saturation problem of the SFCL using magnetic coupling of coils, the iron core with two magnetic paths, which has an air-gap in one of them, was adopted. In this paper, the hysteresis characteristics of SFCL using magnetic coupling of coils, which were wound in the iron core with two magnetic paths, were analyzed. Through comparative analysis on the hysteresis characteristics of the iron core comprising SFCL, the hysteresis characteristics of the iron core with two magnetic paths were confirmed to be kept in the non-saturation region during the fault period and thus, the effective fault current limiting operation of the SFCL using the magnetic coupling of coils could be performed.
히스테리시스 특성을 고려한 자속구속형 고온초전도 사고전류 제한기의 사고전류 제한특성 분석
임성훈,최명호,Lim, Sung-Hun,Choi, Myoung-Ho 한국조명전기설비학회 2007 조명·전기설비학회논문지 Vol.21 No.2
자속구속형 초전도 사고전류 제한기는 평상시 자기적인 결합에 의해 철심의 히스테리시스 손실이 발생하지 않는 특징이 있다. 그러나 사고시에는 사고전류증가로 인해 고온초전도 소자의 저항발생과 함께 철심의 포화가 발생할 경우 제한기의 사고전류제한 특성을 저하시키는 현상이 발생하게 된다. 따라서 본 논문에서는 이를 분석하고 억제하기 위한 설계방안을 도출하기 위해 자속구속형 고온초전도 사고전류 제한기의 구성요소인 자속구속 리액터의 히스테리시스 특성을 고려한 사고전류 제한특성을 분석하였다. 이를 위해 제한기의 등가회로와 사고전류 제한실험으로부터 히스테리시스 곡선을 도출하였다. 1, 2차권선의 인덕턴스 비에 따른 히스테리시스 곡선으로부터 인덕턴스비가 증가함에 따라 제한되는 사고전류크기는 증가한 반면 사고시 자속구속형 사고전류제한기의 구성요소인 철심의 포화가 억제됨을 확인할 수 있었다. The fault current limiting characteristics of a flux-lock type superconducting fault current limiter (SFCL) considering hysteresis characteristics of a flux-lock reactor, which is an essential component of the flux-lock type SFCL, were investigated. In the normal state, the hysteresis loss of iron core in the flux-lock type SFCL does not happen due to its winding's structure. From the equivalent circuit for the flux-lock type SFCL and the fault current limiting experiments, the hysteresis curves could be drawn. Through the hysteresis curves together with the fault current level due to the inductance ratio between the primary and the secondary windings, the increase of the number of turns in the secondary winding of the flux-lock type SFCL made the fault current level increase. On the other hand, the saturation of iron core was prevented.
용융온도와 유지시간이 용융법으로 제작한 고온초전도체의 임계특성에 미치는 영향
임성훈,한태희,박경국,임성우,조동언,한병성,Lim, Sung-Hun,Han, Tae-Hee,Park, Kyung-Kuk,Yim, Seong-Woo,Cho, Dong-Eon,Han, Byoung-Sung 한국전기전자재료학회 1998 전기전자재료학회논문지 Vol.11 No.2
The effects of melting temperature and holding time on the critical current density($J_c$) of $YBa_2Cu_3O_x$ based superconducting bulk fabricated by MPMG process were investigated. The amount of the formed $Y_2BaCuO_5$ phases increased with the melting temperature. However, the value of critical current density was highest at 1120 $^{\circ}C$. With this proper melting temperature, the effect of holding time on the critical characteristics was also investigated. In the case of Ag addition, the volume of the formed $Y_2BaCuO_5$ phase when the amount of Ag addition was 10 wt% and 20 wt% was observed to be highest at 20 minute and 40 minute respectively. But in the specimen without Ag, volume of $Y_2BaCuO_5$ phase increased as the holding time increased. The proper melting temperature and the holding time obtained were 1120 $^{\circ}C$ and 20 minute. The long holding time was not effective for the $J_c$ improvement as well as the formation of $Y_2BaCuO_5$.
임성훈,Lim, Sung-Hun 한국전기전자재료학회 2007 전기전자재료학회논문지 Vol.20 No.10
We investigated the quench velocity of superconducting fault current limiter (SFCL) dependent on the source voltage. $YBa_2Cu_3O_7$ (YBCO) thin film was used as the current limiting element for SFCL. The analysis on the quench velocity of SFCL is essential to determine the capacity of circuit breaker (CB) or coordinate with CB. Generally, the quench velocity of SFCL is related with the short-circuit current. To change the short-circuit current, in this paper, the amplitude of the power source voltage is adjusted. Through the fault current limiting experiments, the quench velocity of SFCL was confirmed to increase fast as the source voltage increased. On the other hand, the peak limited current was shown to increase with steady rate of increase.
철심의 자화특성을 고려한 자속구속형 초전도 사고전류제한기의 특성 분석
임성훈,Lim, Sung-Hun 한국전기전자재료학회 2007 전기전자재료학회논문지 Vol.20 No.11
We investigated the characteristics of a flux-lock type superconducting fault current limiter(SFCL) considering magnetization characteristic of iron core. The flux-lock type SFCL, like other types of SFCLs using the iron core, undergoes the saturation of the iron core during the initial fault time. Therefore, if the design to prevent the saturation of the iron core is considered, the effective fault current limiting operation can be achieved. Through the analysis for its equivalent circuit including the magnetization characteristic of the iron core, the limiting impedance of the flux-lock type SFCL was drawn. The magnetization currents and the limited currents of SFCL, which were dependent on the winding direction and the turns' ratio between two coils, were investigated from the short circuit experiment. It was confirmed that their experimental results agreed with the analysis ones.
자속구속형 고온초전도 사고전류 제한기의 사고제거 후 회복특성
임성훈,Lim, Sung-Hun 한국전기전자재료학회 2007 전기전자재료학회논문지 Vol.20 No.9
To apply the superconducting fault current limiter(SFCL) into a power system, the analysis for its recovery characteristics as well as the consideration for its cooperation with other protecting machine such as a circuit breaker is required. The recovery characteristics of the flux-lock type SFCL like its current limiting characteristics are dependent on the winding direction of two coils. In this paper, the experiments of the current limiting and the recovery characteristics of the flux-lock type SFCL with YBCO thin film were performed. From the analysis on the experimental results due to the winding direction of two coils, the limited fault current in case of the additive polarity winding was observed to be lower than that for the case of the subtractive polarity winding. In addition, the recovery time was found to be faster in case of the additive polarity winding compared to the subtractive polarity winding.