딘브엉,박병규,이상우,박재형,백다현,최인영,서예빈,최진우,김조천 한국대기환경학회 2023 Asian Journal of Atmospheric Environment (AJAE) Vol.17 No.1
The spatial monitoring of submicron particles has become an essential issue due to their negative effects on human health. However, the use of high-cost and high-grade measurement instruments is a challenging investment cost. Thus, a cost-effective optical particle counter (OPC), which is improved measurement quality, has become a good candidate. In this study, two cost-effective OPCs, coupled with a heated inlet tube to reduce the effect of humidity on its measurements, were applied in the field to measure ambient PM10, PM2.5, and PM1 over 1 month. Their 1-h-average and 24-h-average data were compared with those obtained from a reference-grade OPC and a beta attenuation monitor (BAM). In particular, the correlations between the measurement data obtained from them, the differences in the mean values of these data, and the relative errors were evaluated. The PM2.5 data obtained from cost-effective OPCs were comparable to those from BAM at even under high humidity conditions, except for rainy days. The data obtained from the cost-effective OPCs also showed good correlations and low relative errors (i.e., < 7%) compared to the reference-grade OPC, with no significant difference in mean values in terms of the PM2.5 and PM1 data. Although the measurement of PM10 by the cost-effective OPCs showed lower quality than PM2.5 and PM1, the relative errors were still acceptable (i.e., < 18%) compared with those in other studies. Therefore, the cost-effective OPC coupled with a heated inlet tube has the potential to serve as a real-time monitoring instrument for ambient PM2.5 and PM1.
최인영,딘브엉,김조천 한국대기환경학회 2021 한국대기환경학회 학술대회논문집 Vol.2021 No.10
사이클론 분립장치는 1885년 John M. Finch에 의해 개발된 오래된 장치이고, 이에 관련된 연구와 개선은 현대까지도 꾸준히 이어지고 있다. 그리고 입자상물질을 제거하기 위해 입자상물질 제어설비, 전처리 장비, 입자포집 장비 등 다양한 분야에서 사용되고 있다. 그 중 전처리장치로 사용되는 사이클론에 초점을 맞추어 기존 사이클론에 냉각장치를 설치하여 입자상물질 제거효율을 확인하였다. 선행 연구에서는 사이클론 전체를 냉각하여 유입구가 수분의 응결로 인해 막힘 현상이 발생하였다. 본 연구에서는 사이클론 전체가 아닌 입자상물질이 제거가 되는 콘부분만을 냉각하여 온도변화에 따른 입자상물질 제거효율을 연구하였다. 입자상물질은 발생장치에 Arizona Test Dust A1 (PTI, USA)을 사용하여 발생시켰다. 사이클론은 Cut-size 2.5 μm로 설계하여 제작하였으며, 냉각온도는 25~ -25℃로 설정하여 실험을 진행하였다. 실험결과는 사이클론 전후단의 PM2.5 (Particulate matters 2.5 μm)를 기준으로 제거효율을 비교하였다. 실험결과 사이클론의 온도가 상온일 경우 제거효율은 50±3%로 Cut-size 2.5 μm로 설계된 결과에 부합하였으며, 온도가 점차 낮아질수록 제거효율이 증가하는 경향을 확인되었다. 그러나 -25℃ 조건에서의 PM2.5 제거효율이 약 60%로 크게 증가하지 않았다. 결론적으로 입자상물질을 제거효율을 높이기 위한 냉각방법은 소모되는 에너지대비 큰 효과가 나타나지 않는 것으로 사료된다.
김조천,딘브엉,박병규,이상우,박재형,백다현,최인영,서예빈 한국대기환경학회 2022 Asian Journal of Atmospheric Environment (AJAE) Vol.16 No.4
A study on monitoring PM2.5 concentrations at an underground subway station using light scattering and beta attenuation methods was conducted. Six optical particle counters (OPCs), which were representative of the light scattering method and had 16 size channels, were installed at different sampling sites in the waiting room and platforms to compare PM2.5 concentrations, determine PM2.5 /PM10 ratios, and characterize the size distribution based on particle number. In terms of the beta attenuation method, a beta-ray attenuation monitor (BAM) was set up at the platform to compare it with OPCs for one month. It was found that 1h-average PM2.5 concentrations varied at different sampling sites depending on PM composition, while 24h-average PM2.5 concentrations were independent of the sampling sites. There was a significant difference between the means of 1h-average PM2.5 concentrations observed by the BAM and OPC when PM2.5 contributed to less than 50% or higher than 80% of PM10. In contrast, the 24h-average PM2.5 concentrations observed by the BAM and OPC showed the same patterns as each other with an insignificant difference. Therefore, an OPC can be used to monitor the 24h-average PM2.5 concentration in an underground subway station. However, the use of OPC to measure the 1h-average PM2.5 concentration should consider PM composition and other factors. In addition, more frequent calibration is needed on a regular basis.
적외선 광원 재질이 Multi NDIR 측정기 민감도에 미치는 영향 연구
박병규,딘브엉,이상우,이지현,길한뉘,김인영,최인영,김조천 한국대기환경학회 2021 한국대기환경학회 학술대회논문집 Vol.2021 No.10
비분산적외선흡수법(Non-Dispersive infrared, NDIR)의 구성요소로는 광원, 시료셀, 가스필터, 검출기 등이 있다. 이 중 적외선 광원은 NDIR 측정기 민감도에 영향을 끼치는 주요 부분 중 하나이다. 광원의 온도와 재질에 따라 적외선의 세기가 달라지며, 방출하는 스펙트럼에 따라 분자가 흡수하는 적외선의 양이 달라진다. 이러한 차이는 측정기 민감도에 직접적인 영향을 준다. 본 연구에서는 스펙트럼이 다른 적외선 광원 재질이 측정기 민감도에 끼치는 영향을 알아보고자 한다. 본 연구를 위해서 사용된 NDIR은 NARA Controls사의 Multi-Gas Analyzer (NMA-N500)이다. 측정 가스는 CO, SO₂, NO이며, 0~200 ppm 범위를 측정하였다. 적외선 광원은 HAWKEYE사의 IR-Si207(재질: Silicon Carbide)과 HELIOWORKS사의 EK-3430 (재질: Kanthal Filament)을 이용하였으며, 각 광원을 설치한 측정기에 표준가스를 주입하여 분석 신호를 측정하였다. 분석 신호는 가스 주입시작과 동시에 변화 그래프를 확인하고 신호가 안정화되었다고 판단된 시점의 신호를 이용하였다. 측정된 신호값을 이용하여 검정 곡선을 작성한 후 각 광원에 대한 차이점을 살펴보았다. SO₂의 경우, 검정곡선 기울기비가 1.09로 광원의 차이에 따른 변화가 작게 나타났다. 이는 SO₂ 가스의 민감도가 상대적으로 높아 광원의 재질에 따른 영향이 거의 없기 때문이다. 반면 CO와 NO의 경우, 검정곡선 기울기비가 약 1.20으로 상대적으로 큰 차이를 나타내었다. 이 두 가스는 낮은 민감도를 가지기 때문에 1.2배 높은 기울기를 가지는 광원을 사용하는 것이 작은 차이임에도 민감도를 높이는 방안이 된다. 이를 통해 3가지 이상(CO, SO₂, NO등)의 가스를 측정하는 Multi-Gas Analyzer에는 Silicon Carbide로 이루어진 적외선 광원을 사용하는 것이 바람직하다.
서예빈,딘브엉,김승재,백다현,정권,김조천 한국대기환경학회 2023 Asian Journal of Atmospheric Environment (AJAE) Vol.17 No.1
The feasibility of a novel type of moss (Parkortanso No. 1 synthesized from Racomitrium japonicum, Dozy and Molk) to capture CO2 in urban areas was demonstrated. The effects of light intensity (500, 1000, and 1500 μmol/m2.s), ambient temperature (10 °C, 25 °C, and 35 °C), age (1-year-old and 3 years old), and leaf color (bright and dark green) on the CO2 removal caused by the moss concerned were investigated. It was determined that stronger light intensity resulted in higher CO2 removal by the target moss. The moss showed the best CO2 capture at 25 °C, while the CO2- capturing capacities declined when the ambient temperatures were 10 °C and 35 °C. Three years old bright green moss was found to have higher CO2- capturing capacity than 1 year old. Similarly, bright green moss exhibited the best CO2 uptake out of the mosses concerned. The highest net CO2 emission of the moss was − 1.94 ± 0.72 kgCO2/ m2.year, which was comparable to other moss and plant species. Consequently, the bright green and old Parkortanso No. 1 moss are recommended for a green roof application in terms of CO2 capture.