RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      성견 하악골에서 다양한 드릴링 속도에 따른 임플란트 초기 골유착에 관한 비교 연구 = Comparative study on early osseointegration of implants according to various drilling speeds in the mandible of dogs

      한글로보기

      https://www.riss.kr/link?id=T14167292

      • 0

        상세조회
      • 0

        다운로드
      서지정보 열기
      • 내보내기
      • 내책장담기
      • 공유하기
      • 오류접수

      부가정보

      다국어 초록 (Multilingual Abstract) kakao i 다국어 번역

      I. Purpose
      Successful osseointegration of implants can be influenced by the drilling speeds of implant installation. This study evaluated the effect of drilling speed on early bone healing in mandible of dogs.

      II. Material and methods
      Six young adult dogs were selected and two mandibular premolars and two molars were extracted from both sides. After two months of healing, 3 hydroxyapatite surfaced Ф3.7*10mm fixtures (OneQ, Dentis, Daegu, Korea) were implanted with drilling speeds of 50, 800, and 1200 rpm on the right side first and then the left side after 2 weeks. Implant stability quotient (ISQ) was measured upon insertion, and after 4 weeks for the right side, and after 2 weeks for the left side using Osstell Mentor®. The animals were euthanized after allowing 4 weeks and 2 weeks of healing for the right and left side of the mandible, respectively. The implant and surrounding tissue were histologically analyzed.
      III. Results
      The implants were stable upon insertion for both groups and although implant stability steadily increased for 4 weeks, no statistically significant differences were observved between the surgical protocols.
      From histomorphological evaluation, a significant increase from 2 to 4 weeks was observed for all groups for bone-implant contact(BIC), whereas no significant differences were detected between 2 and 4 weeks for the 50 and 800 rpm groups.
      Based on the ISQ measurement, all implants were measured higher than 60 for each drilling speed from both 2 and 4 weeks group. The 1200 rpm group showed a higher value than the 50 rpm group at 2 weeks and 4 weeks. (p<0.05)
      From the results of a histomorphometric analysis, new bone formation around the implant was highest for the 800 rpm group at 2 weeks and the 1200 rpm group at 4 weeks. The BIC of the superior half of the alveolar bone was highest for the 800 rpm group at 2 weeks and the 1200 rpm group at 4 weeks. There was no statistically significant differences.

      IV. Conclusion
      This study suggests that 50, 800, and 1200 rpm are drilling speeds which can expect favorable outcome, yet, higher drilling speed presented overall the best biological responses. However, further studies are needed for statistical significance.
      번역하기

      I. Purpose Successful osseointegration of implants can be influenced by the drilling speeds of implant installation. This study evaluated the effect of drilling speed on early bone healing in mandible of dogs. II. Material and methods Six young ad...

      I. Purpose
      Successful osseointegration of implants can be influenced by the drilling speeds of implant installation. This study evaluated the effect of drilling speed on early bone healing in mandible of dogs.

      II. Material and methods
      Six young adult dogs were selected and two mandibular premolars and two molars were extracted from both sides. After two months of healing, 3 hydroxyapatite surfaced Ф3.7*10mm fixtures (OneQ, Dentis, Daegu, Korea) were implanted with drilling speeds of 50, 800, and 1200 rpm on the right side first and then the left side after 2 weeks. Implant stability quotient (ISQ) was measured upon insertion, and after 4 weeks for the right side, and after 2 weeks for the left side using Osstell Mentor®. The animals were euthanized after allowing 4 weeks and 2 weeks of healing for the right and left side of the mandible, respectively. The implant and surrounding tissue were histologically analyzed.
      III. Results
      The implants were stable upon insertion for both groups and although implant stability steadily increased for 4 weeks, no statistically significant differences were observved between the surgical protocols.
      From histomorphological evaluation, a significant increase from 2 to 4 weeks was observed for all groups for bone-implant contact(BIC), whereas no significant differences were detected between 2 and 4 weeks for the 50 and 800 rpm groups.
      Based on the ISQ measurement, all implants were measured higher than 60 for each drilling speed from both 2 and 4 weeks group. The 1200 rpm group showed a higher value than the 50 rpm group at 2 weeks and 4 weeks. (p<0.05)
      From the results of a histomorphometric analysis, new bone formation around the implant was highest for the 800 rpm group at 2 weeks and the 1200 rpm group at 4 weeks. The BIC of the superior half of the alveolar bone was highest for the 800 rpm group at 2 weeks and the 1200 rpm group at 4 weeks. There was no statistically significant differences.

      IV. Conclusion
      This study suggests that 50, 800, and 1200 rpm are drilling speeds which can expect favorable outcome, yet, higher drilling speed presented overall the best biological responses. However, further studies are needed for statistical significance.

      더보기

      목차 (Table of Contents)

      • ABSTRACT ⅳ
      • Ⅰ. 서 론 1
      • Ⅱ. 실험재료 및 방법 3
      • Ⅲ. 결과 7
      • ABSTRACT ⅳ
      • Ⅰ. 서 론 1
      • Ⅱ. 실험재료 및 방법 3
      • Ⅲ. 결과 7
      • Ⅳ. 고찰 9
      • Ⅴ. 결론 11
      • VI. 참고문헌 12
      더보기

      분석정보

      View

      상세정보조회

      0

      Usage

      원문다운로드

      0

      대출신청

      0

      복사신청

      0

      EDDS신청

      0

      동일 주제 내 활용도 TOP

      더보기

      주제

      연도별 연구동향

      연도별 활용동향

      연관논문

      연구자 네트워크맵

      공동연구자 (7)

      유사연구자 (20) 활용도상위20명

      이 자료와 함께 이용한 RISS 자료

      나만을 위한 추천자료

      해외이동버튼