    광중합형 의치상의 적합도 향상을 위한 2단계 방법 개발연구 = Research and development of two stage technique for optimum fit of light-polymerized record bases

    한글로보기

    https://www.riss.kr/link?id=T12172897

    • 0

      상세조회
    • 0

      다운로드
    서지정보 열기
    • 내보내기
    • 내책장담기
    • 공유하기
    • 오류접수

    부가정보

    다국어 초록 (Multilingual Abstract) kakao i 다국어 번역

    Research and development of two stage technique for optimum fit of light-polymerized record base


    Min Goo Kang, D.D.S

    Esthetic Restorative Dentistry
    Graduate School of Clinical Dentistry, Korea University
    (Director: Professor Jae Jun Ryu, D.D.S., M.S.D., Ph.D.)



    ABSTRACT

    Objectives. This thesis describes that two-stage polymerized technique is designed and analyzed to fabricate stable and accurate record base.

    Materials and Methods. From edentulous maxillary stone, the labial/buccal aspects of the residual ridge are blocked out. The cast is coated with a thin layer of petroleum jelly. In stone cast, four cases are considered. The first case draws a line along the end of the border. The second, third, and four cases do lines at 5, 10, 15 mm below of alveolar crest along the palatal plane, respectively. From each case, the Triad sheets are divided into two U-shaped pieces. Each pieces are polymerized for 15 minutes under visible light with a wavelength of 475nm and light intensity of 90mw/cm2. The polymerized sheets are polymerized again by adding resin to the cutting region. After 24 hours, impression material is injcted into the inside of the record base. The record base is located in the cast stone. Using instron, the record base is pressed by 40N pressure for 5 minutes. Finally, the mass of impression material is measured after removed. the mass is evaluated at the space between record base and cast and compared among the five groups using ANOVA test, Wilcoxon Rank-Sum test and Tukey-Kramer HSD test(α=0.05).

    Results. From the expriments, 10 and 15mm cases are comparable to each other. The mean of 10mm case and the std of 15mm cases are best among four cases, respectively. There are trade-off between 10 and 15mm cases in terms of mean and std. Finally, the two-stage polymerized technique can stably improve the fitness of the denture base.

    Conclusion. Finally, the two-stage polymerized technique can stably improve the fitness of the denture base.


    Keyword: record base, Triad sheet, two-stage polymerized, alveolar crest, fit
    번역하기

    Research and development of two stage technique for optimum fit of light-polymerized record base Min Goo Kang, D.D.S Esthetic Restorative Dentistry Graduate School of Clinical Dentistry, Korea University (Director: Professor Jae Jun Ryu, D.D.S., M...

    Research and development of two stage technique for optimum fit of light-polymerized record base


    Min Goo Kang, D.D.S

    Esthetic Restorative Dentistry
    Graduate School of Clinical Dentistry, Korea University
    (Director: Professor Jae Jun Ryu, D.D.S., M.S.D., Ph.D.)



    ABSTRACT

    Objectives. This thesis describes that two-stage polymerized technique is designed and analyzed to fabricate stable and accurate record base.

    Materials and Methods. From edentulous maxillary stone, the labial/buccal aspects of the residual ridge are blocked out. The cast is coated with a thin layer of petroleum jelly. In stone cast, four cases are considered. The first case draws a line along the end of the border. The second, third, and four cases do lines at 5, 10, 15 mm below of alveolar crest along the palatal plane, respectively. From each case, the Triad sheets are divided into two U-shaped pieces. Each pieces are polymerized for 15 minutes under visible light with a wavelength of 475nm and light intensity of 90mw/cm2. The polymerized sheets are polymerized again by adding resin to the cutting region. After 24 hours, impression material is injcted into the inside of the record base. The record base is located in the cast stone. Using instron, the record base is pressed by 40N pressure for 5 minutes. Finally, the mass of impression material is measured after removed. the mass is evaluated at the space between record base and cast and compared among the five groups using ANOVA test, Wilcoxon Rank-Sum test and Tukey-Kramer HSD test(α=0.05).

    Results. From the expriments, 10 and 15mm cases are comparable to each other. The mean of 10mm case and the std of 15mm cases are best among four cases, respectively. There are trade-off between 10 and 15mm cases in terms of mean and std. Finally, the two-stage polymerized technique can stably improve the fitness of the denture base.

    Conclusion. Finally, the two-stage polymerized technique can stably improve the fitness of the denture base.


    Keyword: record base, Triad sheet, two-stage polymerized, alveolar crest, fit

    더보기

    목차 (Table of Contents)

    • 목 차
    • Ⅰ. 서론 1
    • 목 차
    • Ⅰ. 서론 1
    • Ⅱ. 연구 재료 및 방법 3
    • Ⅲ. 연구 결과 12
    • Ⅳ. 총괄 및 고찰 14
    • Ⅴ. 결 론 18
    • 참고문헌 19
    • 영문초록 22