RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      검색결과 좁혀 보기

      선택해제
      • 좁혀본 항목 보기순서

        • 원문유무
        • 등재정보
        • 학술지명
        • 주제분류
        • 발행연도
        • 작성언어
        • 저자
          펼치기
      • 무료
      • 기관 내 무료
      • 유료
      • Optimizing Contrast Medium Injection for Coronary CT Angiography Using Myocardial CT Perfusion Data

        Tomizawa Nobuo,Chou Shengpu,Matsuoka Satoshi,Yamamoto Kodai,Inoh Shinichi,Nojo Takeshi,Kumamaru Kanako Kunishima,Fujimoto Shinichiro,Nakamura Sunao 아시아심장혈관영상의학회 2019 Cardiovascular Imaging Asia Vol.3 No.4

        Objective: To derive and validate a formula to predict the optimal amount of contrast medium for coronary CT angiography (CTA) from CT perfusion (CTP) data during comprehensive cardiac CT. Materials and Methods: The derivation and validation group consisted of 196 and 41 patients, respectively. Dynamic CTP was performed under adenosine triphosphate stress of 0.14 mg/kg/min, followed by rest coronary CTA. Time to peak (TTP) and peak enhancement (PE) in the left ventricle during CTP was recorded. The amount of contrast medium during CTA was 0.8×body weight (kg) in the derivation group. A formula to determine the amount of contrast medium needed to achieve an enhancement of 370 Hounsfield unit (HU) in CTA was derived using TTP, PE, body weight, and heart rate. The amount of contrast medium required during CTA in the validation group was determined by this formula. Results: The mean amount of contrast medium during CTA did not differ between the derivation and validation groups (49.3±8.0 mL vs. 47.9±12.9 mL, p=0.39). The mean coronary artery enhancement was slightly lower in the validation group (400±55 HU vs. 380±46 HU, p=0.03) with smaller interpatient variability (p=0.02) than in the derivation group. The proportion of patients with an optimal enhancement of 320 HU to 420 HU significantly increased from 54% to 75% (p=0.01) when the formula was used. Conclusion: Adjusting the amount of contrast medium using dynamic CTP data could reduce the interpatient variability of coronary enhancement during comprehensive cardiac CT.

      • KCI등재후보

        Low Iodine Dose is Related with Overestimation of Extracellular Volume Derived from Cardiac CT

        Hiroaki Arakawa,Nobuo Tomizawa,Shengpu Chou,Satoshi Matsuoka,Kodai Yamamoto,Shinichi Inoh,Takeshi Nojo,Kanako Kunishima Kumamaru,Shinichiro Fujimoto,Sunao Nakamura 아시아심장혈관영상의학회 2020 Cardiovascular Imaging Asia Vol.4 No.2

        Objective: To assess the relationship between the amount of injected contrast medium and the extracellular volume (ECV) value during cardiac CT and to propose a minimum amount of contrast medium necessary to correctly calculate ECV. Materials and Methods: A total of 95 patients who underwent comprehensive cardiac CT were included. Patients first underwent myocardial CT perfusion (CTP) with a contrast medium dose determined by the body weight (<70 kg: 50 mL; 70–89 kg: 55 mL; ≥90 kg: 60 mL). Coronary CT angiography (CTA) scan followed with a contrast medium dose of 0.8×body weight (kg). We defined the ECV value calculated after CTP as ECVCTP, and we used the ECV value calculated after the CTA exam as the reference standard (ECVref). We calculated the difference in ECV values (ECVdiff) as ECVCTP-ECVref. Results: The injected iodine doses during CTP and the entire exam were 284±50 and 559± 69 mg iodine/kg, respectively. There was a weak but significant negative relationship (R2 =0.07, p=0.01) between the injected iodine dose during CTP and ECVdiff. The ECVdiff of patients who received an injected iodine dose of <285 mg iodine/kg during CTP was significantly higher (2.7±4.1 vs. 0.8±3.4%, p=0.02) than that of the remaining patients. Conclusion: ECV derived from cardiac CT might be overestimated when a small amount of contrast medium is injected. Inj

      연관 검색어 추천

      이 검색어로 많이 본 자료

      활용도 높은 자료

      해외이동버튼