Syed Sabir Hussain Bukhari,Thomas A. Lipo,Byung-il Kwon 전력전자학회 2015 ICPE(ISPE)논문집 Vol.2015 No.6
Numerous industrial facilities involve the installation of load transformers with their respective loads. As loads are turned on and off, these transformers are energized and de-energized, respectively, which can cause serious disturbances to sensitive loads. An inrush current, which typically occurs when a transformer is energized, can easily be observed using on-line uninterruptible power supply (UPS) systems feeding such loads. This paper proposes an on-line UPS system that eliminates the inrush current phenomenon caused by the energizing of load transformers. The UPS inverter specifically utilizes a fast acting current control scheme that enables it to regulate current for the load during all energizing conditions of load transformer connected to the UPS system.
Syed Sabir Hussain Bukhari,Shahid Atiq,Thomas A. Lipo,Byung-il Kwon 대한전기학회 2016 Journal of Electrical Engineering & Technology Vol.11 No.3
Sudden voltage drops and outages frequently disturb the operation of sensitive loads for domestic, commercial, and industrial use. In some cases, these events may even impair the functioning of relevant equipment. To maintain power under such conditions, a UPS system is usually installed. Once a disturbance happens at the grid side, the line-interactive UPS system takes over the load to prevent an interruption. But, due to magnetic saturation of the transformer, a significant inrush current may occur for the transformer-coupled loads during this transition. The generation of such transient currents may in turn decrease the line voltage and activates over-current protecting devices of the system. In this work, a cost-effective, line-interactive UPS system is proposed that eliminates the inrush current phenomenon associated with transformer-coupled loads. The strategy was implemented by connecting a standard current-regulated voltage source inverter (CRVSI) to the secondary winding of the load transformer. During any transient condition at the grid side, the load current is monitored and regulated to achieve either seamless compensation of the load current or complete transferal of load from grid to the inverter. Experimental results were obtained for a prototype under all possible operating conditions so as to validate the performance of the proposed topology.
Nocturnal Urine Production in Women With Global Polyuria
Thomas F. Monaghan,Adriana M. Kavoussi,Christina W. Agudelo,Syed N. Rahman,Kyle P. Michelson,Donald L. Bliwise,Jason M. Lazar,Lori A. Birder,Upeksha S. Alwis,Johan Vande Walle,Alan J. Wein,Jerry G. Bl 대한배뇨장애요실금학회 2020 International Neurourology Journal Vol.24 No.3
Purpose: Low nocturnal urine production (NUP) may be sufficient to rule out global polyuria (GP) in men. This study determines the sensitivity of indices for nocturnal polyuria (NP), defined as nocturnal polyuria index (NPi; nocturnal urine volume/24-hour urine volume) ≥0.33 or NUP ≥90 mL/hr, for detecting GP in women. Methods: Data were analyzed from 2 prospective protocols involving subjects recruited from a urology ambulatory care unit and a continence clinic. Women ≥18 years with nocturia were included if they met either of 2 common criteria for GP: (1) ≥40 mL/kg/24 hr or (2) ≥3,000 mL/24 hr. Results: Thirty-one women were included (NPi, 28.6 [21.3–40.7]; NUP, 100.8 [68.3–135.8] mL/hr). At the ≥40 mL/kg/24-hr cutoff, 40% and 63% of women reporting ≥1 nocturnal void(s) (n=30) had NPi ≥0.33 and NUP ≥90 mL/hr, respectively. Additionally, 53% and 71% of subjects reporting ≥2 nocturnal voids (n=17) had NPi ≥0.33 and NUP ≥90 mL/hr, respectively. At the ≥3,000 mL/24-hr cutoff, 38% and 69% of women reporting ≥1 nocturnal void(s) (n=13) had NPi ≥0.33 and NUP ≥90 mL/hr, respectively, and 63% and 88% of subjects reporting ≥2 nocturnal voids (n=8) had NPi ≥0.33 and NUP ≥90 mL/hr, respectively. By extension, 37%–62% of women with nocturia and GP did not have NP by NPi ≥0.33 criteria, and 12%–37% did not have NP by NUP ≥90 mL/hr criteria. Conclusions: Indices of excess nighttime urination do not reliably predict GP in women. A full-length voiding diary may be particularly important in the evaluation of women with nocturia. Nocturia in women merits further consideration as a distinct entity.
Bukhari, Syed Sabir Hussain,Atiq, Shahid,Lipo, Thomas A.,Kwon, Byung-il The Korean Institute of Electrical Engineers 2016 Journal of Electrical Engineering & Technology Vol.11 No.3
Sudden voltage drops and outages frequently disturb the operation of sensitive loads for domestic, commercial, and industrial use. In some cases, these events may even impair the functioning of relevant equipment. To maintain power under such conditions, a UPS system is usually installed. Once a disturbance happens at the grid side, the line-interactive UPS system takes over the load to prevent an interruption. But, due to magnetic saturation of the transformer, a significant inrush current may occur for the transformer-coupled loads during this transition. The generation of such transient currents may in turn decrease the line voltage and activates over-current protecting devices of the system. In this work, a cost-effective, line-interactive UPS system is proposed that eliminates the inrush current phenomenon associated with transformer-coupled loads. The strategy was implemented by connecting a standard current-regulated voltage source inverter (CRVSI) to the secondary winding of the load transformer. During any transient condition at the grid side, the load current is monitored and regulated to achieve either seamless compensation of the load current or complete transferal of load from grid to the inverter. Experimental results were obtained for a prototype under all possible operating conditions so as to validate the performance of the proposed topology.