        Electronic Ballast Using a Symmetrical Half-bridge Inverter Operating at Unity-Power-factor and High Efficiency

        Hiralal M. Suryawanshi,Vijay B. Borghate,Manojkumar R. Ramteke,Krishna L. Thakre 전력전자학회 2006 JOURNAL OF POWER ELECTRONICS Vol.6 No.4

        This paper deals with novel electronic ballast based on single-stage power processing topology using a symmetrical half-bridge inverter and current injection circuit. The half-bridge inverter drives the output parallel resonant circuit and injects current through the power factor correction (PFC) circuit. Because of high frequency current injection and high frequency modulated voltage, the proposed circuit maintains the unity power factor (UPF) with low THD even under wide variation in ac input voltage. This circuit needs minimum and lower sized components to achieve the UPF and high efficiency. This leads to an increase in reliability of ballast at low cost. Furthermore, to reduce cost, the electronic ballast is designed for two series-connected fluorescent lamps (FL). The analysis and experimental results are presented for (2 × 36 Watt) fluorescent lamps operating at 50 ㎑ switching frequency and input line voltage (230 V, 50 ㎐).

      • SCIESCOPUSKCI등재

        Electronic Ballast Using a Symmetrical Half-bridge Inverter Operating at Unity-Power-factor and High Efficiency

        Suryawanshi Hiralal M.,Borghate Vijay B.,Ramteke Manojkumar R.,Thakre Krishna L. The Korean Institute of Power Electronics 2006 JOURNAL OF POWER ELECTRONICS Vol.6 No.4

        This paper deals with novel electronic ballast based on single-stage power processing topology using a symmetrical half-bridge inverter and current injection circuit. The half-bridge inverter drives the output parallel resonant circuit and injects current through the power factor correction (PFC) circuit. Because of high frequency current injection and high frequency modulated voltage, the proposed circuit maintains the unity power factor (UPF) with low THD even under wide variation in ac input voltage. This circuit needs minimum and lower sized components to achieve the UPF and high efficiency. This leads to an increase in reliability of ballast at low cost. Furthermore, to reduce cost, the electronic ballast is designed for two series-connected fluorescent lamps (FL). The analysis and experimental results are presented for ($2{\times}36$ Watt) fluorescent lamps operating at 50 kHz switching frequency and input line voltage (230 V, 50 Hz).

      • KCI등재

        Multilevel Inverter to Reduce Common Mode Voltage in AC Motor Drives Using SPWM Technique

        Mohan M. Renge,Hiralal M. Suryawanshi 전력전자학회 2011 JOURNAL OF POWER ELECTRONICS Vol.11 No.1

        In this paper, an approach to reduce common-mode voltage (CMV) at the output of multilevel inverters using a phase opposition disposed (POD) sinusoidal pulse width modulation (SPWM) technique is proposed. The SPWM technique does not require computations therefore, this technique is easy to implement on-line in digital controllers. A good tradeoff between the quality of the output voltage and the magnitude of the CMV is achieved in this paper. This paper realizes the implementation of a POD-SPWM technique to reduce CMV using a five-level diode clamped inverter for a three phase induction motor. Experimental and simulation results demonstrate the feasibility of the proposed technique.

      • SCIESCOPUSKCI등재

        Multilevel Inverter to Reduce Common Mode Voltage in AC Motor Drives Using SPWM Technique

        Renge, Mohan M.,Suryawanshi, Hiralal M. The Korean Institute of Power Electronics 2011 JOURNAL OF POWER ELECTRONICS Vol.11 No.1

        In this paper, an approach to reduce common-mode voltage (CMV) at the output of multilevel inverters using a phase opposition disposed (POD) sinusoidal pulse width modulation (SPWM) technique is proposed. The SPWM technique does not require computations therefore, this technique is easy to implement on-line in digital controllers. A good tradeoff between the quality of the output voltage and the magnitude of the CMV is achieved in this paper. This paper realizes the implementation of a POD-SPWM technique to reduce CMV using a five-level diode clamped inverter for a three phase induction motor. Experimental and simulation results demonstrate the feasibility of the proposed technique.

      • KCI등재

        Three-Phase AC-to-DC Resonant Converter Operating in High Power Factor Mode in High-Voltage Applications

        Madhuri A. Chaudhari,Hiralal M. Suryawanshi,Abhishek Kulwal,Mahesh K. Mishra 전력전자학회 2008 JOURNAL OF POWER ELECTRONICS Vol.8 No.1

        In this paper a three-phase ac-to-dc resonant converter with high input power factor and isolated output is proposed. To improve the input power factor of the converter, high frequency current is injected into the input of the three-phase diode bridge rectifier. It is injected through an impedance network consisting of a series of L-C branches from the output of the high frequency three-phase inverter. A narrow switching frequency variation is required to regulate the output voltage. A design example with different design curves is illustrated along with the component ratings. Experimental verification of the converter is performed on a prototype of 3 kW, 1000 V output, operating above 300 kHz. Experimental results confirm the concept of the proposed converter. Narrow switching frequency variation is required to regulate the output voltage.

      • KCI등재

        Detection of Incipient Faults in Induction Motors using FIS, ANN and ANFIS Techniques

        Makarand S. Ballal,Hiralal M. Suryawanshi,Mahesh K. Mishra 전력전자학회 2008 JOURNAL OF POWER ELECTRONICS Vol.8 No.2

        The task performed by induction motors grows increasingly complex in modern industry and hence improvements are sought in the field of fault diagnosis. It is essential to diagnose faults at their very inception, as unscheduled machine down time can upset critical dead lines and cause heavy financial losses. Artificial intelligence (AI) techniques have proved their ability in detection of incipient faults in electrical machines. This paper presents an application of AI techniques for the detection of inter-turn insulation and bearing wear faults in single-phase induction motors. The single-phase induction motor is considered a proto type model to create inter-turn insulation and bearing wear faults. The experimental data for motor intake current, rotor speed, stator winding temperature, bearing temperature and noise of the motor under running condition was generated in the laboratory. The different types of fault detectors were developed based upon three different AI techniques. The input parameters for these detectors were varied from two to five sequentially. The comparisons were made and the best fault detector was determined.

      • SCIESCOPUSKCI등재

        Detection of Incipient Faults in Induction Motors using FIS, ANN and ANFIS Techniques

        Ballal, Makarand S.,Suryawanshi, Hiralal M.,Mishra, Mahesh K. The Korean Institute of Power Electronics 2008 JOURNAL OF POWER ELECTRONICS Vol.8 No.2

        The task performed by induction motors grows increasingly complex in modern industry and hence improvements are sought in the field of fault diagnosis. It is essential to diagnose faults at their very inception, as unscheduled machine down time can upset critical dead lines and cause heavy financial losses. Artificial intelligence (AI) techniques have proved their ability in detection of incipient faults in electrical machines. This paper presents an application of AI techniques for the detection of inter-turn insulation and bearing wear faults in single-phase induction motors. The single-phase induction motor is considered a proto type model to create inter-turn insulation and bearing wear faults. The experimental data for motor intake current, rotor speed, stator winding temperature, bearing temperature and noise of the motor under running condition was generated in the laboratory. The different types of fault detectors were developed based upon three different AI techniques. The input parameters for these detectors were varied from two to five sequentially. The comparisons were made and the best fault detector was determined.

      • SCIESCOPUSKCI등재

        Three-Phase AC-to-DC Resonant Converter Operating in High Power Factor Mode in High-Voltage Applications

        Chaudhari, Madhuri A.,Suryawanshi, Hiralal M.,Kulwal, Abhishek,Mishra, Mahesh K. The Korean Institute of Power Electronics 2008 JOURNAL OF POWER ELECTRONICS Vol.8 No.1

        In this paper a three-phase ac-to-dc resonant converter with high input power factor and isolated output is proposed. To improve the input power factor of the converter, high frequency current is injected into the input of the three-phase diode bridge rectifier. It is injected through an impedance network consisting of a series of L-C branches from the output of the high frequency three-phase inverter. A narrow switching frequency variation is required to regulate the output voltage. A design example with different design curves is illustrated along with the component ratings. Experimental verification of the converter is performed on a prototype of 3 kW, 1000 V output, operating above 300 kHz. Experimental results confirm the concept of the proposed converter. Narrow switching frequency variation is required to regulate the output voltage.

      • KCI등재

        Application of Multiple Parks Vector Approach for Detection of Multiple Faults in Induction Motors

        Tushar G. Vilhekar,Makarand S. Ballal,Hiralal M. Suryawanshi 전력전자학회 2017 JOURNAL OF POWER ELECTRONICS Vol.17 No.4

        The Park’s vector of stator current is a popular technique for the detection of induction motor faults. While the detection of the faulty condition using the Park’s vector technique is easy, the classification of different types of faults is intricate. This problem is overcome by the Multiple Park’s Vector (MPV) approach proposed in this paper. In this technique, the characteristic fault frequency component (CFFC) of stator winding faults, rotor winding faults, unbalanced voltage and bearing faults are extracted from three phase stator currents. Due to constructional asymmetry, under the healthy condition these characteristic fault frequency components are unbalanced. In order to balanced them, a correction factor is added to the characteristic fault frequency components of three phase stator currents. Therefore, the Park’s vector pattern under the healthy condition is circular in shape. This pattern is considered as a reference pattern under the healthy condition. According to the fault condition, the amplitude and phase of characteristic faults frequency components changes. Thus, the pattern of the Park’s vector changes. By monitoring the variation in multiple Park’s vector patterns, the type of fault and its severity level is identified. In the proposed technique, the diagnosis of faults is immune to the effects of unbalanced voltage and multiple faults. This technique is verified on a 7.5 hp three phase wound rotor induction motor (WRIM). The experimental analysis is verified by simulation results.

      • SCIESCOPUSKCI등재

        Application of Multiple Parks Vector Approach for Detection of Multiple Faults in Induction Motors

        Vilhekar, Tushar G.,Ballal, Makarand S.,Suryawanshi, Hiralal M. The Korean Institute of Power Electronics 2017 JOURNAL OF POWER ELECTRONICS Vol.17 No.4

        The Park's vector of stator current is a popular technique for the detection of induction motor faults. While the detection of the faulty condition using the Park's vector technique is easy, the classification of different types of faults is intricate. This problem is overcome by the Multiple Park's Vector (MPV) approach proposed in this paper. In this technique, the characteristic fault frequency component (CFFC) of stator winding faults, rotor winding faults, unbalanced voltage and bearing faults are extracted from three phase stator currents. Due to constructional asymmetry, under the healthy condition these characteristic fault frequency components are unbalanced. In order to balanced them, a correction factor is added to the characteristic fault frequency components of three phase stator currents. Therefore, the Park's vector pattern under the healthy condition is circular in shape. This pattern is considered as a reference pattern under the healthy condition. According to the fault condition, the amplitude and phase of characteristic faults frequency components changes. Thus, the pattern of the Park's vector changes. By monitoring the variation in multiple Park's vector patterns, the type of fault and its severity level is identified. In the proposed technique, the diagnosis of faults is immune to the effects of unbalanced voltage and multiple faults. This technique is verified on a 7.5 hp three phase wound rotor induction motor (WRIM). The experimental analysis is verified by simulation results.