RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      검색결과 좁혀 보기

      선택해제
      • 좁혀본 항목 보기순서

        • 원문유무
        • 원문제공처
          펼치기
        • 등재정보
          펼치기
        • 학술지명
          펼치기
        • 주제분류
          펼치기
        • 발행연도
          펼치기
        • 작성언어
        • 저자
          펼치기

      오늘 본 자료

      • 오늘 본 자료가 없습니다.
      더보기
      • 무료
      • 기관 내 무료
      • 유료
      • Progress in Improvement of Safety Information Transmission System

        Sewon Park,Wiho Ha,Sohyeon Lee,Hyunki Kim,Juyeol Yun,Sungho Lee,Minwoo Lee 한국방사성폐기물학회 2023 한국방사성폐기물학회 학술논문요약집 Vol.21 No.1

        In response to a regulatory mandate, all nuclear licensees are obligated to establish an information system that can provide essential information in the event of a radiation emergency by connecting the monitoring data of the Safety Parameter Display System (SPDS) or equivalent system to the Korea Institute of Nuclear Safety (KINS). Responding to this responsibility, the Korea Atomic Energy Research Institute (KAERI) has established the Safety Information Transmission System (SITS), which enables the collection and real-time monitoring of safety information. The KAERI monitors and collects safety information, which includes data from the HANARO Operation Work Station (OWS) and the HANARO & HANARO Fuel Fabrication Plant (HFFP) Radioactivity Monitoring System (RMS), and the Environmental Radiation Monitoring System (ERMS) & meteorological data. Currently, the transmission of this safety information to the AtomCARE server of the KINS takes place via the SITS server located in the Emergency Operations Facility (EOF). However, the multi-path of transmission through SITS has caused problems such as an increase in data transmission interruptions and errors, as well as delays in identifying the cause and implementing system recovery measures. To address these issues, a new VPN is currently being constructed on the servers of nuclear facilities that generate and manage safety information to establish a direct transmission system of safety information from each nuclear facility to the AtomCARE server. The establishment of a direct transmission system that eliminates unnecessary transit steps is expected to result in stable information transmission and minimize the frequency of data transmission interruptions. As of the improvement progress, a security review was conducted in the second and third quarters of 2022 to evaluate the security of newly introduced VPNs to the nuclear facility server, and based on the results of the review, security measures were strengthened. In the fourth quarter of 2022, the development of a direct transmission system for safety information began, and it is scheduled to be completed by the fourth quarter of 2023. The project includes the construction of the transmission system, system inspection, and comprehensive data stability testing. Afterward, the existing SITS located in the EOF will be renamed as the Safety Information Display System (SIDS), and there are plans to remove any unused servers and VPNs.

      • KCI등재

        Lab-based Simulation of Carton Clamp Truck Handling - Preliminary FEA and Analysis of Handling Test Courses

        Park, Jongmin,Kim, Jongsoon,Kim, Dongkeon,Chang, Sewon,Kim, Ghiseok Korea Society of Packaging Science and Technology 2017 한국포장학회지 Vol.23 No.3

        Carton clamp truck is widely perceived as the high-efficient handling equipment of factory premises and warehouse by its capability of palletless handling. Therefore, the significance of a lab-based handling simulation is becoming higher with the growth of clamp truck usage. In this study, preliminary FEA and design of handling test courses for the lab-based simulation of carton clamp truck handling were performed, and the PSD analyses were performed for the modified one for the test course proposed by Park et al. (2017) as well as ASTM D 6055 and ISTA 3B standards. For the vibration in all directions, the vibration energy intensity analyzed by ISTA 3B standard showed higher than that by the other two cases. A FEA was performed for the handling operation of the sudden stop of the clamps after lifting the target HCP (heavyweight refrigerator corrugated package, w=180 kgf) up to the specified height. The slip distance between the clamp arm and the target HCP was 0.85 mm. The simulation result of 0.85 mm was 3.7 times lower than the experimental result (3.2 mm) obtained by Park et al. (2017), and it was estimated that the deviation comes from both the experimental error by weight imbalance of target HCP, and excessive simplification during the FE modelling of target HCP.

      • Medical Response to the Injured in a Radiological Emergency at the Korea Atomic Energy Research Institute

        Sewon Park,Sohyeon Lee,Young-suk Jeoung,Hyunki Kim 한국방사성폐기물학회 2023 한국방사성폐기물학회 학술논문요약집 Vol.21 No.2

        The nuclear licensee must ensure that the nuclear or radiological emergency preparedness and response organization is explicitly defined and staffed with adequate numbers of competent and assessed personnel for their roles. This paper describes the responsibilities of medical and support personnel for the medical action of casualties in the event of a radiological emergency at the KAERI. Currently, there is one medical personnel (nurse) in KAERI, and a total of eight medical support personnel are designated for medical response in the event of a radiological emergency. These medical support personnel are designated as one or two of the on-site response personnel at each nuclear facility, operating as a dedicated team of A, B (4 people each). In the event of a radiological emergency, not all medical support personnel are mobilized, but members of the dedicated medical team, which includes the medical support personnel of the nuclear facility where the accident has occurred, are summoned. Medical and support personnel will first gather in the onsite operational support center (OSC)/technical support center (TSC) to prepare and stand by for the medical response to injured when a radiological emergency is declared. They should take radiation protective measures, such as wearing radiation protective clothing and dosimeters, before entering the onsite of a radiological emergency, because injuries sustained during a radiological emergency may be associated with radioactive contamination. In the event of an injury, direct medical treatment such as checking the patient’s vitals, first aid, and decontamination will be carried out by medical personnel, while support personnel are mainly responsible for contacting the transfer hospital, reporting the patient’s condition, accompanying the ambulance, filling out the emergency medical treatment record, and supporting medical personnel. In order to respond appropriately to the occurrence of injuries, we regularly conduct emergency medical supplies education and medical training for medical support personnel to strengthen their capabilities.

      • Improvements to KAERIX for Effective Information Exchange in Radiological Emergencies

        Sewon Park,Bongseok Kim,Hyunki Kim 한국방사성폐기물학회 2023 한국방사성폐기물학회 학술논문요약집 Vol.21 No.2

        In the event of a radiological emergency at a nuclear facility, the exchange of information on the accident situation is very important in the response process. For this reason, international organizations such as the IAEA and the EU operate systems to exchange information in the event of a radiological emergency. In south korea, the emergency response information exchange system (ERIX) developed by KINS is operated for use by the national radiological emergency response organization. The ERIX enables the exchange of emergency response information between organizations such as the government, nuclear operators, local authorities, KINS and KIRAMS. The KAERI has developed the KAERI emergency response information exchange system (KAERIX) for the exchange of accident information and emergency response information between the emergency response organizations of the KAERI in the event of a radiological emergency. This system is web-based using HTML, runs on internal network and is only available to KAERI staff. Recently, as the need for optimizing and upgrading KAERIX has arisen, improvements have been derived. The main improvement is optimizing KAERIX for Microsoft Edge to minimize errors. At present, it is optimized for Internet Explorer, but optimizing it for Microsoft Edge mode has become essential due to Microsoft discontinuing support for Internet Explorer. Another major improvement involves adding functions in ERIX to KAERIX, such as displaying the deletion/ correction status of input information and providing notifications for important information registration. Ultimately, KAERIX will be upgraded and optimized in 2024, reflecting improvements.

      • SCOPUSKCI등재SCIE

        Radiation safety for pain physicians: principles and recommendations

        ( Sewon Park ),( Minjung Kim ),( Jae Hun Kim ) 대한통증학회 2022 The Korean Journal of Pain Vol.35 No.2

        C-arm fluoroscopy is a useful tool for interventional pain management. However, with the increasing use of C-arm fluoroscopy, the risk of accumulated radiation exposure is a significant concern for pain physicians. Therefore, efforts are needed to reduce radiation exposure. There are three types of radiation exposure sources: (1) the primary X-ray beam, (2) scattered radiation, and (3) leakage from the X-ray tube. The major radiation exposure risk for most medical staff members is scattered radiation, the amount of which is affected by many factors. Pain physicians can reduce their radiation exposure by use of several effective methods, which utilize the following main principles: reducing the exposure time, increasing the distance from the radiation source, and radiation shielding. Some methods reduce not only the pain physician’s but also the patient’s radiation exposure. Taking images with collimation and minimal use of magnification are ways to reduce the intensity of the primary X-ray beam and the amount of scattered radiation. It is also important to carefully select the C-arm fluoroscopy mode, such as pulsed mode or low-dose mode, for ensuring the physician’s and patient’s radiation safety. Pain physicians should practice these principles and also be aware of the annual permissible radiation dose as well as checking their radiation exposure. This article aimed to review the literature on radiation safety in relation to C-arm fluoroscopy and provide recommendations to pain physicians during C-arm fluoroscopy-guided interventional pain management.

      • Preliminary Experiment of Radioactive Caesium Analysis in Seawater Using Ammonium Phosphomolybdate Coprecipitation

        Sewon Park,Hyojin Kim,Jieun Lee,Yeong-rok Kang 한국방사성폐기물학회 2023 한국방사성폐기물학회 학술논문요약집 Vol.21 No.1

        Cs-137, a radioactive isotope of caesium, is a commonly occurring fission product that is generated during the nuclear fission of U-235 and other fissionable isotopes in both nuclear reactors and weapons. Due to its long half-life of about 30 years and propensity to accumulate in sediments and marine organisms, Cs-137 is considered a major radionuclide for environmental radioactivity monitoring. In April 2021, as the Japanese government decided to discharge Fukushima contaminated water into the sea, the monitoring of marine radioactivity in South Korea has become increasingly significant. In this study, as an initial step towards establishing a standardized procedure for analyzing radioactive caesium in seawater, the radioactivity of Cs-137 was analyzed on a 2 L of seawater spiked with 10 Bq of Cs-137 standard solution supplied by KRISS. The seawater was collected from Im-nang Beach, situated at a distance of approximately 2 kilometers from DIRAMS. The radioactivity of Cs-137 in seawater was determined according to the improved AMP procedure presented by M.Aoyama in 2000. The seawater was pretreated using Ammonium Phosphomolybdate (AMP) coprecipitation, which has a high selectivity for caesium (Kd = ~5500), and the activity of Cs-137 was determined by gammaspectroscopy and subsequently corrected via the weight yield. The weight yield of the dried AMP/Cs compound was more than 93%. For the gamma-spectroscopy analysis, the AMP/Cs compound was dissolved in a cylindrical U8 beaker with NaOH to ensure that its shape and volume were consistent with the CRM (KRISS, 221U890-1) used to calibrate the detector. The dissolved compound was then positioned directly onto the detector housing and subjected to a measurement duration of 80,000 seconds utilizing a p-type HPGe (Ortec, GEM60) with a relative efficiency of 54%. The activity of Cs-137 was determined to be 10.81 Bq, confirming the reproducibility of the AMP coprecipitation and weight yield methods. The present experiment was carried out using a 2 L sample, but a large volume of seawater would be required to achieve a sufficient minimum detectable activity (MDA) for Cs-137 in natural seawater. Thus, a standardized procedure for analysis of radioactive caesium in natural seawater will be established through the analysis of a large volume of seawater in future studies.

      연관 검색어 추천

      이 검색어로 많이 본 자료

      활용도 높은 자료

      해외이동버튼