RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      검색결과 좁혀 보기

      선택해제
      • 좁혀본 항목 보기순서

        • 원문유무
        • 원문제공처
        • 등재정보
        • 학술지명
        • 주제분류
        • 발행연도
        • 작성언어
        • 저자
          펼치기

      오늘 본 자료

      • 오늘 본 자료가 없습니다.
      더보기
      • 무료
      • 기관 내 무료
      • 유료
      • KCI등재

        Four flap suspension technique for prevention of bottoming out after breast reduction

        Yuksel Kankaya,Melike Oruc,Nezih Sungur,Ozlem Colak Aslan,Koray Gursoy,Kadri Ozer,U?ur Kocer 대한외과학회 2015 Annals of Surgical Treatment and Research(ASRT) Vol.90 No.1

        Purpose: Bottoming-out deformity is accepted as the most important disadvantage of inferior pedicle breast reduction. For prevention of this deformity, different techniques are used in combination with inferior pedicle. In this study, we aimed to prevent bottoming-out deformity by producing an internal bra effect through combination of inferior pedicle technique with 2 superior and 2 inferior dermal flaps that were raised from each side of the pedicle. Methods: Thirteen patients whose medical records became available during the follow-up period at Ankara Training and Research Hospital from January 2010 to January 2015 were included in this study. We retrospectively obtained patient medical records including demographic characteristics and clinical data. Superior dermal flaps were planned on both sides of the pedicle 2 cm inferior to the lower border of areola and inferior dermal flaps were planned 6 cm inferior to the superior dermal flaps. The superior and inferior dermal flaps were secured to the periosteum of the 2nd and 4th ribs respectively with permanent sutures. Results: Preoperatively, the average distance between the inframammary fold and areola was 13.9 cm (range, 11–18 cm). The average amount of breast parenchymal resection was 745 g (range, 612–1,496 g). The average distance between the inframammary fold and the lower border of the areola was 7.9 cm (range, 7.5–9 cm) on the postoperative first-year measurements. Conclusion: In conclusion, according to our study, suspension technique to prevent bottoming-out deformity is associated with an easier technique without the need for alloplastic or allogenic materials. Since fixation is performed to the ribs instead of soft tissues like the pectoral fascia or muscle, we believe that this fixation is more long lasting and can be an effective alternative to other suspension techniques.

      • SCOPUSKCI등재

        Barbed sutures versus conventional tenorrhaphy in flexor tendon repair: An ex vivo biomechanical analysis

        Colak, Ozlem,Kankaya, Yuksel,Sungur, Nezih,Ozer, Kadri,Gursoy, Koray,Serbetci, Kemal,Kocer, Ugur Korean Society of Plastic and Reconstructive Surge 2019 Archives of Plastic Surgery Vol.46 No.3

        Background The management of flexor tendon injuries has evolved in recent years through industrial improvements in suture materials, refinements of repair methods, and early rehabilitation protocols. However, there is no consensus on the ideal suture material and technique. This study was conducted to compare the tensile strength, repair time, and characteristics of 4-strand cruciate, modified Kessler, and 4-strand horizontal intrafiber barbed sutures for flexor tenorrhaphy with a 12-mm suture purchase length in an animal model. Methods The right third deep flexors of 60 adult Leghorn chicken feet were isolated and repaired with a 12-mm suture purchase length. The tendons were randomly assigned to three groups of equal number (n=20 each). Groups 1 and 2 received 4-strand cruciate and modified Kessler repair with conventional suture materials, respectively. A 4-strand horizontal intrafiber barbed suture technique was used in group 3. The repaired tendons were biomechanically tested for tensile strength, 2-mm gap resistance, and mode of failure. Repair times were also recorded. Results The maximum tensile strength until failure was $44.6{\pm}4.3N$ in group 1, $35.7{\pm}5.2N$ in group 2, and $56.7{\pm}17.3N$ in group 3. The barbed sutures were superior to the other sutures in terms of the load needed for 2-mm gap formation (P<0.05). Furthermore, the barbed sutures showed the shortest repair time (P<0.05). Conclusions This study found that 4-strand horizontal intrafiber barbed suture repair with a 12-mm purchase length in a chicken flexor tendon injury model showed promising biomechanical properties and took less time to perform than other options.

      • SCOPUSKCI등재

        A Tie-Over Dressing Using a Silicone Tube to Graft Deep Wounds

        Bektas, Cem Inan,Kankaya, Yuksel,Ozer, Kadri,Baris, Ruser,Aslan, Ozlem Colak,Kocer, Ugur Korean Society of Plastic and Reconstructive Surge 2013 Archives of Plastic Surgery Vol.40 No.6

        Background The most common cause of skin graft failure is the collection of blood or serous fluid underneath the graft. In our study, we describe the use of silicone tube for tie-over dressing to secure the skin graft margins with the aim of decreasing loss of the skin graft, particularly in grafting of deep wounds. Methods Between March 2008 and July 2011, we used this technique in 17 patients with skin defects with depths ranging from 3.5 to 8 mm (mean, 5.5 mm). First, the skin graft was sutured with 3/0 silk suture material from its corners. Then, a silicone round drain tube was sutured with 3/0 absorbable polyglactin 910 over the margins of the graft. Finally, long silk threads were tied over the bolus dressing, and the tie-over dressing was completed in the usual fashion. Results The mean follow-up was 7 months (range, 2-10 months) in the outpatient clinic. Graft loss on the graft margins due to hematoma or seroma was not developed. The results of adhesion between the graft and wound bed peripherally was excellent. Conclusions In our study, we suggest that use of a silicone tube for additional pressure on the edges of skin grafts in case of reconstruction of deep skin defects.

      • KCI등재

        A Tie-Over Dressing Using a Silicone Tube to Graft Deep Wounds

        Cem Inan Bektas,Yuksel Kankaya,Kadri Ozer,Ruser Baris,Ozlem Colak Aslan,Ugur Kocer 대한성형외과학회 2013 Archives of Plastic Surgery Vol.40 No.6

        Background The most common cause of skin graft failure is the collection of blood or serous fluid underneath the graft. In our study, we describe the use of silicone tube for tie-over dressing to secure the skin graft margins with the aim of decreasing loss of the skin graft, particularly in grafting of deep wounds. Methods Between March 2008 and July 2011, we used this technique in 17 patients with skin defects with depths ranging from 3.5 to 8 mm (mean, 5.5 mm). First, the skin graft was sutured with 3/0 silk suture material from its corners. Then, a silicone round drain tube was sutured with 3/0 absorbable polyglactin 910 over the margins of the graft. Finally, long silk threads were tied over the bolus dressing, and the tie-over dressing was completed in the usual fashion. Results The mean follow-up was 7 months (range, 2−10 months) in the outpatient clinic. Graft loss on the graft margins due to hematoma or seroma was not developed. The results of adhesion between the graft and wound bed peripherally was excellent. Conclusions In our study, we suggest that use of a silicone tube for additional pressure on the edges of skin grafts in case of reconstruction of deep skin defects.

      • KCI등재

        Barbed sutures versus conventional tenorrhaphy in flexor tendon repair: An ex vivo biomechanical analysis

        Özlem Çolak Aslan,Yüksel Kankaya,Nezih Sungur,Kadri Özer,Koray Gürsoy,Kemal Şerbetçi,Uğur Koçer 대한성형외과학회 2019 Archives of Plastic Surgery Vol.46 No.3

        Background The management of flexor tendon injuries has evolved in recent years through industrial improvements in suture materials, refinements of repair methods, and early rehabilitation protocols. However, there is no consensus on the ideal suture material and technique. This study was conducted to compare the tensile strength, repair time, and characteristics of 4-strand cruciate, modified Kessler, and 4-strand horizontal intrafiber barbed sutures for flexor tenorrhaphy with a 12-mm suture purchase length in an animal model. Methods The right third deep flexors of 60 adult Leghorn chicken feet were isolated and repaired with a 12-mm suture purchase length. The tendons were randomly assigned to three groups of equal number (n=20 each). Groups 1 and 2 received 4-strand cruciate and modified Kessler repair with conventional suture materials, respectively. A 4-strand horizontal intrafiber barbed suture technique was used in group 3. The repaired tendons were biomechanically tested for tensile strength, 2-mm gap resistance, and mode of failure. Repair times were also recorded. Results The maximum tensile strength until failure was 44.6±4.3 N in group 1, 35.7±5.2 N in group 2, and 56.7±17.3 N in group 3. The barbed sutures were superior to the other sutures in terms of the load needed for 2-mm gap formation (P<0.05). Furthermore, the barbed sutures showed the shortest repair time (P<0.05). Conclusions This study found that 4-strand horizontal intrafiber barbed suture repair with a 12-mm purchase length in a chicken flexor tendon injury model showed promising biomechanical properties and took less time to perform than other options.

      연관 검색어 추천

      이 검색어로 많이 본 자료

      활용도 높은 자료

      해외이동버튼