http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
이강희(K-H Lee),강흥석(H-S Kang),송기남(K-N Song),윤경호(K-H Yoon),최명환(M-H Choi) 대한기계학회 2004 대한기계학회 춘추학술대회 Vol.2004 No.4
Vibration characteristics of the FIV test loop for the Flow-Induced Vibration(FIV) study of a PWR partial(5x5) fuel assembly are investigated by the Finite Element(FE) analysis and the modal test. For the FE analysis, 3-D beam element is used for the pipes and the test section and mass element used for the valves and flanges. The 'U' restrainer stiffness determined by numerical simulation is used for the FE model. The result of the FE analysis is compared with that of the modal test. The higher mode similarity between the test and analysis is observed in a few low modes. After that, the mode similarity reduce as the mode goes high. It is concluded that the first to the third vibration modes are observed at the lower parts of the 6 inches restoring line, followed by a local mode at the test section, and the natural frequencies of the modes are 22.4 Hz, 26.0 Hz, 27.5 Hz and 31.4 Hz.