Michelle Foo,Julian Maingard, BBiomedSci,Jonathan Hall,Yifan Ren,Goran Mitresk, BBiomed,Lee-Anne Slater,Ronil Chandra,Winston Chong,Ashu Jhamb,Jeremy Russell,Hong Kuan Kok,Mark Brooks,Hamed Asadi 대한신경중재치료의학회 2021 Neurointervention Vol.16 No.2
Purpose Low-profile, self-expandable stents have broadened therapeutic options available for definitive treatment of intracranial aneurysms. The novel Low-Profile Visualized Intraluminal Support (LVIS) EVO stent extends upon the success of its predecessor, the LVIS Jr stent, aiming to enable higher visibility and greater opening ability within a self-expandable and fully retrievable microstent system. In this study, we aim to report the early safety and feasibility experience with the LVIS EVO stent. Materials and Methods A multicenter, retrospective, observational study was conducted on patients who had intracranial aneurysms treated with the LVIS EVO stent across 3 Australian neurovascular centers between February 2020 and September 2020. Short-term technical and clinical outcomes were evaluated. Results A total of 22 LVIS EVO stents were successfully implanted to treat 15 aneurysms (3 ruptured, 12 unruptured) in 15 patients. Aneurysms ranged from 2 mm to 35 mm in dome height. The LVIS EVO stent was used for stent-assisted coiling in 11 patients and flow diversion in 4 patients. There were no device-related procedural complications. There were 2 cases of peri-procedural symptomatic thromboembolic complications and no procedure-related mortality. At early radiological follow up, 10 patients had complete occlusion, 4 patients had small neck remnants, and 1 patient who was managed with flow diversion had a residual aneurysm. Conclusion Early experience with the LVIS EVO stent demonstrated safety and feasibility for stent-assisted coiling as well as flow diversion for intracranial aneurysms. In this heterogeneous cohort, including ruptured, complex, and large aneurysms, all cases were technically successful.
Jay Gajera,Julian Maingard,Michelle Foo,Yifan Ren,Anthony Lamanna,Daniel Nour,Jonathan Hall,Dylan Kurda,David Tan,Shivendra Lalloo,Ramon Martin Francisco Bañez,Jeremy Russell,Lee-Anne Slater,Ronil Vik 대한신경중재치료의학회 2022 Neurointervention Vol.17 No.1
Purpose: Advances in endovascular technology have expanded the treatment options for intracranial aneurysms. Intrasaccular flow diversion is a relatively new technique that aims to disrupt blood inflow at the neck of the aneurysm, hence promoting intrasaccular thrombosis. The Woven EndoBridge device (WEB; MicroVention, Aliso Viejo, CA, USA) is an US Food and Drug Administration approved intrasaccular flow diverter for wide-necked aneurysms. We report the early interim clinical and radiological outcomes of patients with both ruptured and unruptured intracranial aneurysms (IAs) treated using the WEB device in an Australian population. Materials and Methods: A retrospective analysis was done of patients with ruptured or unruptured IAs who received treatment with WEB across 5 Australian neuroendovascular referral centers between May 2017 and November 2020. Angiographic occlusion was assessed with time-of-flight magnetic resonance angiography. Complications were recorded and clinical outcomes were assessed using the modified Rankin scale at follow-up. Results: In total, 66 aneurysms were treated in 63 patients, with successful deployment of the WEB device in 98.5% (n=65). Eighteen (26.9%) ruptured aneurysms were included. Failure of deployment occurred in a single case. Adjunct coiling and/or stenting was performed in 20.9% (n=14) cases. Sixty-two patients with 65 aneurysms using a WEB device were followed up (mean=9.1 months), and 89.4% of these had complete aneurysm occlusion while 1.5% remained patent. Functional independence was achieved in 93.5% of cases. Conclusion: Early results following the use of WEB devices in Australia demonstrate safety and adequate aneurysm occlusion comparable to international literature.