RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      검색결과 좁혀 보기

      선택해제

      오늘 본 자료

      • 오늘 본 자료가 없습니다.
      더보기
      • 무료
      • 기관 내 무료
      • 유료
      • KCI등재

        The Feasibility of Translaminar Screws in the Subaxial Cervical Spine: Computed Tomography and Cadaveric Validation

        Woojin Cho,Jason T. Le,Adam L. Shimer,Brian C. Werner,John A. Glaser,Francis H. Shen 대한정형외과학회 2022 Clinics in Orthopedic Surgery Vol.14 No.1

        Background: The use of translaminar screws may serve as a viable salvage method for complicated cases. To our understanding, the study of the feasibility of translaminar screw insertion in the actual entire subaxial cervical spine has not been carried out yet. The purpose of this study was to report the feasibility of translaminar screw insertion in the entire subaxial cervical spine. Methods: Eighteen cadaveric spines were harvested from C3 to C7 and 1-mm computed tomography (CT) scans and three-dimensional reconstructions were created to exclude any bony anomaly. Thirty anatomically intact segments were collected (C3, 2; C4, 3; C5, 3; C6, 8; and C7, 14), and randomly arranged. Twenty-one segments were physically separated at each vertebral level (group S), while 9 segments were not separated from the vertebral column and left in situ (group N–S). CT measurement of lamina thickness was done for both group S and group N–S, and manual measurement of various length and angle was done for group S only. Using the trajectory proposed by the previous studies, translaminar screws were placed at each level. Screw diameter was the same or 0.5 mm larger than the proposed diameter based on CT measurement. Post-insertion CT was performed. Cortical breakage was checked either visually or by CT. Results: When 1° and 2° screws of the same size were used, medial cortex breakage was found 13% and 33% of the time, respectively. C7 was relatively safer than the other levels. With larger-sized screws, medial cortex breakage was found in 47% and 46% of 1° and 2° screws, respectively. There were no facet injuries due to the screws in group N–S. Conclusions: Translaminar screw insertion in the subaxial cervical spine is feasible only when the lamina is thick enough to avoid any breakage that could lead to further complications. The authors do not recommend inserting translaminar screws in the subaxial cervical spine except in some salvage cases in the presence of a thick lamina.

      연관 검색어 추천

      이 검색어로 많이 본 자료

      활용도 높은 자료

      해외이동버튼