http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
Eskandari, Habibollah Korean Chemical Society 2004 Bulletin of the Korean Chemical Society Vol.25 No.8
A spectrophotometric and first derivative spectrophotometric method was developed in aquatic Tween 80 micellar solutions for selective determination of nickel without using any pre-separation step. 1-(2-Pyridylazo)-2-naphthol (PAN), as a sensitive chromogenic complexing agent formed a red-colored Ni(II)-PAN complex in Tween 80 media with satisfactory solubility and stability. Conditions such as pH, PAN concentration, type and concentration of micellizing agent were optimized. Molar absorptivity of Ni-PAN complex was found $4.62\;{\times}\;10^4L\;cm^{?1}\;mol^{?1}$ at 569 nm, under the optimum condition. Calibration graphs were derived by zero, first and second derivative spectrophotometry at maximum wavelengths of 569, 578 and 571 nm with linear ranges of 30-1800, 20-2500 and 30-2000 ng $mL^{?1}$ , respectively. Precision as standard deviation as well as accuracy as recovery percent were in the range of 1-20 ng $mL^{?1}$, and 93.3-103.3%, respectively, for the entire of the linear ranges. Spectrophotometric detection limit was 3 ng $mL^{?1}$ and effects of diverse ions on the first derivative determination of nickel were studied to investigate selectivity of the method. Interferences of cobalt and copper on the nickel determination were prevented using o-phenanthroline as masking agent. The recommended procedures were applied to the various synthetic and stainless steel alloys, tea leaves and human hair, with satisfactory results.
Eskandari, Habibollah,Karkaragh, Gholamhassan Imanzadeh Korean Chemical Society 2003 Bulletin of the Korean Chemical Society Vol.24 No.12
The reaction of ${\alpha}$-Benzilmonoxime with palladium(II) produces a green complex in triton X-100 micellar media. Palladium has been determined using zero and first derivative spectrophotometric methods. The absorbances of Pd(II)- ${\alpha}$--benzilmonoxime complex at 441.8 and 677.0 nm in 0.10 M perchloric acid solution were monitored and linear working ranges of 0.3-12.0 and 0.7-20 ${\mu}$g mL$^{-1}$ with detection limits of 0.07 and 0.10 ${\mu}$g $mL^-1$ were obtained, respectively. Also, recoveries in the range of 92.8 to 100.1% and relative standard deviations in the range of 0.4 to 7.1% were obtained. First derivative spectrophotometry has also been applied for palladium determination under the optimum condition. The linear dynamic range of 0.2-24.0 ${\mu}$g $mL^{-1}$ palladium with relative standard deviations of 0.6-6.9% and recoveries in the range of 94.9-102.5% has been obtained by first derivative spectrophotometry. The method shows high selectivity because of the high concentration of acid used, which prevents formation of complexes of ${\alpha}$--benzilmonoxime with the other cations. The palladium complex formed was stable at least one day. The method was successfully applied to the determination of palladium in some synthetic palladium alloys and palladium-charcoal powder.