Fire performance curves for unprotected HSS steel column
M. Shahria Alam,A.H.M. Muntasir Billah,Shahriar Quayyum,Mahmud Ashraf,A.N.M. Rafi,Ahmad Rteil 국제구조공학회 2013 Steel and Composite Structures, An International J Vol.15 No.6
The behaviour of steel column at elevated temperature is significantly different than that atambient temperature due to its changes in the mechanical properties with temperature. Reported literaturesuggests that steel column may become vulnerable when exposed to fire condition, since its strength andcapacity decrease rapidly with temperature. The present study aims at investigating the lateral load resistanceof non-insulated steel columns under fire exposure through finite element analysis. The studied parametersinclude moment-rotation behaviour, lateral load-deflection behaviour, stiffness and ductility of columns atdifferent axial load levels. It was observed that when the temperature of the column was increased, there wasa significant reduction in the lateral load and moment capacity of the non-insulated steel columns. Moreover,it was noted that the stiffness and ductility of steel columns decreased sharply with the increase intemperature, especially for temperatures above 400°C. In addition, the lateral load capacity and the momentcapacity of columns were plotted against fire exposure time, which revealed that in fire conditions, thenon-insulated steel columns experience substantial reduction in lateral load resistance within 15 minutes offire exposure.