http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
혼합날개가 부착된 6×6 봉다발 부수로에서의 열전달 향상을 위한 실험적 연구
변선준,신용철,민경호,방윤곤,채영종 한국기계기술학회 2015 한국기계기술학회지 Vol.17 No.2
The present experimental study investigates single-phase heat transfer coefficients downstream of support grid in 6×6 rod bundles. Support grid with Split mixing vanes enhance heat transfer in rod bundles by generating turbulence but this turbulence is confined to a short distance. Support grid with large scale vortex flow(LSVF) mixing vanes enhanced heat transfer to a longer distance. In this study, the experiments were performed at reynolds numbers of 50,000. The characteristics of the heat transfer enhancement of the Split mixing vane and those of the LSVF mixing vane were compared. The results showed that the characteristics of the heat transfer enhancement of rods by the Split mixing vane were limited to 10 Dh after the spacer grid, but those by the LSVF mixing vane were maintained until 15 Dh after the spacer grid. For the reynolds number of 50,000, the heat transfer enhancement effect was 3.0% greater when using the LSVF mixing vane than when using the Split mixing vane between the 1 ∼ 15 Dh interval after the spacer grid.
혼합날개가 부착된 6×6 봉다발 부수로에서의 열전달 향상을 위한 실험적 연구
변선준,신용철,민경호,방윤곤,채영종 한국기계기술학회 2015 한국기계기술학회지 Vol.17 No.2
The present experimental study investigates single-phase heat transfer coefficients downstream of support grid in 6×6 rod bundles. Support grid with Split mixing vanes enhance heat transfer in rod bundles by generating turbulence but this turbulence is confined to a short distance. Support grid with large scale vortex flow(LSVF) mixing vanes enhanced heat transfer to a longer distance. In this study, the experiments were performed at reynolds numbers of 50,000. The characteristics of the heat transfer enhancement of the Split mixing vane and those of the LSVF mixing vane were compared. The results showed that the characteristics of the heat transfer enhancement of rods by the Split mixing vane were limited to 10 Dh after the spacer grid, but those by the LSVF mixing vane were maintained until 15 Dh after the spacer grid. For the reynolds number of 50,000, the heat transfer enhancement effect was 3.0% greater when using the LSVF mixing vane than when using the Split mixing vane between the 1 ∼ 15 Dh interval after the spacer grid.
원전 주제어실 기밀도 시험에서 추적가스희석법의 시험원 신뢰성 데이터 검증
성지훈(Ji Hun Sung),노영진(Young Jin Noh),조재호(Jae Ho Cho),채영종(Young Jong Chae),심인보(In Bo Shim),배희수(Hee Soo Bae) 대한설비공학회 2017 대한설비공학회 학술발표대회논문집 Vol.2017 No.6
원자력발전소 주제어실은 운전원이 상주하면서 발전소를 운전하는 곳으로서 비상시에도 발전소의 안전한 정지 및 안정성 확보를 위해 외부 방사능이나 유해물질로부터 운전원을 보호할 수 있도록 설계되어 있다. 이러한 주제어실 거주성 확보를 위해 미국과 우리나라에서는 ‘ASTM E741(추적가스희석법)에 따라 In-Leakage Test를 수행하여 거주성을 평가하도록 법제화 하고 있다. ASTM E741은 추적가스의 농도 변화를 측정하여 외부공기유입량을 확인하는 시험방법으로서 주제어실과 같은 단일구역의 기밀도를 평가하는 일반적인 방법이다. 본 연구에서는 ASTM E741에서 요구하는 방법과 절차에 따라 주제어실 거주성평가를 위한 시험절차서를 개발하고, 이 시험절차서를 사용하여 두 시험원이 같은 조건에서 반복시험을 수행하였다. 반복시험의 목적은 시험원이 시험절차서에 따라 시험을 수행하였을 경우 그 결과가 얼마나 유사한 값을 나타내는지 통계적 유의성을 확인하는 것이며, 본 논문에서는 시험원들의 신뢰성을 두 집단의 평균값 차이를 확인하는 t-검정 통해 확인하였다.
원전 주제어실 기밀도시험 데이터의 측정불확도 추정에 관한 연구
노영진(Young Jin Noh),성지훈(Ji Hun Sung),배희수(Hee Soo Bae),채영종(Young Jong Chae),조재호(Jae Ho Cho),심인보(In Bo Shim) 대한설비공학회 2017 대한설비공학회 학술발표대회논문집 Vol.2017 No.6
본 연구는 구역경계가 분명한 단일구역에서 ASTM E741의 농도감소법에 따른 기밀도시험을 수행한 데이터의 측정불확도를 추정한 사례를 통하여 향후 원전 주제어실 기밀도시험의 측정불확도 추정에 적용하기 위하여 ASTM E741에서 제시하는 측정불확도 추정 절차를 KS Q ISO/IEC 17025에 따라 분석하였다.