이재봉(Jae-Bong Lee),이병성(Byung-Sung Lee),김상준(Sang-Joon Kim),장상옥(Sang-Ok Jang),한용희(Yong-Huei Han),오재형(Jae-Hyoung Oh) 한국조명·전기설비학회 2004 한국조명·전기설비학회 학술대회논문집 Vol.2004 No.5월
The primary failure causes of underground distribution power cables are water penetration in insulation layer and stress enhancement at inner semi-conductive layer. Accordingly, it is needed to improve the materials and the structure of power cables for extending lifetime and preventing failure. We also use super smooth class material as a inner semi-conductive layer. The newly developed cables are improved in AC breakdown voltage after ageing tests.
송현석(Hyun-Seok Song),이재봉(Jae-Bong Lee),장상옥(Sang-Ok Jang),한용희(Yang-Huei Han),오재형(Jae-Hyoung Oh) 한국조명·전기설비학회 2004 한국조명·전기설비학회 학술대회논문집 Vol.2004 No.5월
Recently polymer arresters are being used widely but we don"t have appropriate long term characteristics test methods. Therefore we need to develop special test facility to evaluate long term reliability of polymer arresters. It"s polymeric housing can be degraded by environmental stress and the interface between housing and inner module can be affected by moisture absorption. This moisture absorption can cause leakage current and tracking in the interface. We developed multi stress accelerated ageing test facility to simulate field conditions including UV, temperature, humidity, voltage, salt fog and rain. In addition, we carried out field exposure test at the outdoor test yard and characteristics analysis of field operated specimens to evaluate accelerating factor of this accelerated aging test.
김동명(Dong-Myung Kim),최선규(Sun-Kyu Choi),장상옥(Sang-Ok Jang),오재형(Jae-Hyoung Oh) 한국조명·전기설비학회 2004 한국조명·전기설비학회 학술대회논문집 Vol.2004 No.5월
This paper describes the testing facility to demonstrate the performance of the distribution class circuit breakers and switchgears and the testing methods. The field-test evaluation system consists of two parts. One is the distribution system for simulation of the condition on interruption mode of switches which are installed in the system and tested by the AFG(Artificial Fault Generator) and the thunderbolt generator just like in the real field. The other is a laboratory for confirmation of the important characteristics regarding to the insulation, gas, environment durability of equipment. For the failure mode, a FMEA(Failure Modes and Effects Analysis) technique which is a kind of a structural analysis to consider a counter-plan was employed.