Effect of suction head on inception and development of cavitation in a Francis turbine model
Mohammad Abu Shahzer(모하메드 아부 사져),Seung-Jun Kim(김승준),Yong Cho(조용),Sung-Hoon Choo(추성훈),Hyeon-Woo Nam(남현우),Jin-Hyuk Kim(김진혁) 한국유체기계학회 2022 유체기계 연구개발 발표회 논문집 Vol.2022 No.6
Francis turbine is one of the highly efficient turbines which converts hydraulic energy to mechanical energy. At lower flow rate operating conditions, the turbines stable operation is affected due to the downstream swirl instabilities. Cavitation is also a very common and severe problem in these turbines due to which turbine components may fail because of erosion and pressure fluctuations. In the turbine, the suction head affects the cavitations inception and development. A numerical investigation of the effect of suction head on cavitation at part load condition is attempted in the present study using CFX code. The suction head is evaluated based on creating different suction pressure at the draft tube outlet. The steady-state numerical calculations are performed with a structured and unstructured grid. For the acceptance of generated grid, the grid convergence index is also calculated. Reynolds averaged Navier-Stokes (RANS) equations are solved accompanying the Rayleigh-Plesset model to capture the turbulent flow with cavitation. An experiment is also performed for the verification of the numerical results. As the suction head increases, the cavitation is initiated and developed and both the efficiency and power decreases. The head loss in the draft tube is maximum for fully developed cavitation with 2% deviation from without cavitation case for which the loss is minimum. The vortex rope strength for the higher values of suction heads is higher compared to lower values of suction heads. Similarly, the swirl intensity is also higher for higher suction heads. The deciding parameter of the suction head can be predicted for the stable operation of the turbine using the current investigation.
비속도 170급 프란시스 수차: Thoma number 변화에 따른 정격 조건에서의 과도상태 유동특성
모하메드 아부 사져(Mohammad Abu Shahzer),김승준(Seung-Jun Kim),노민수(Min-Su Roh),김성(Sung Kim),김진혁(Jin-Hyuk Kim) 한국에너지학회 2024 에너지공학 Vol.33 No.1
본 연구에서는 프란시스 수차의 운전 안정성과 캐비테이션 발생 가능성을 예측하는데 주로 사용되는 지표인 Thoma number의 변화에 따른 수차의 수력학적 성능과 유동 특성 분석 연구를 수행하였다. 수치해석을 통하여 캐비테이션 발달을 정밀하게 예측하기 위해 다상 모델 및 Unsteady Reynolds-averaged Navier-Stokes 방정식을 사용하였다. 수치해석의 정확성을 확보하기 위하여 격자 의존성 시험을 수행하였고, 실험 및 수치해석의 결과를 비교함으로써 수치 해석 모델의 유효성을 입증하였다. Thoma number의 변화에 따른 유동 특성 분석을 위해 선정된 두 개의 Thoma number (0.1211 및 0.3633) 조건에서 수력학적 성능은 비슷한 결과를 나타내었다. Thoma number가 낮은 경우 가이드 베인과 러너 사이의 영역에서는 비정상적인 압력 패턴이 더욱 발달하였으나 러너 영역에서는 Thoma number에 상관없이 유사한 유동특성을 보였다. 드래프트 튜브에서의 유동 특성을 비교한 결과, Thoma number에 따른 축 방향 속도 및 원주 방향 속도의 변화가 크지 않음을 확인하였다. 따라서 정격 조건에서의 Thoma number 변화는 러너 및 드래프트 튜브에서의 압력 맥동 및 유동 특성에 큰 영향을 주지 않는 것으로 분석하였다. 이러한 연구 결과는 프란시스 수차의 설계 및 운전에 관한 연구에서 활용될 수 있다. Francis turbine is efficient at converting hydraulic to mechanical energy, but it faces stability issues and cavitation problems at different outlet pressures. Thoma number ( ) influences cavitation even at rated conditions, leading to erosion and pressure fluctuations, which can cause turbine component failures. In the current study, a 170-class Francis turbine that was operating at rated condition underwent a detailed examination to evaluate its performance and flow behaviour under various Thoma numbers. For accurate flow physics description, we employed the Unsteady Reynolds-averaged Navier-Stokes equation. The two-phase model was used to simulate cavitation, and the Grid Convergence Index was used to guarantee grid accuracy. Our numerical approach dependability was proven by comparison with experimental data. For both (0.1211 and 0.3633), constant hydraulic performance with no appreciable variations was observed. In the vaneless area, abnormal pressure patterns were visible, including the initial blade passing frequency. Except for pressure fluctuations brought on by variations in output pressure, flow properties like meridional velocity and flow angle remained constant in the runner region regardless of . Within the draft tube, the axial and circumferential velocities were identical. Thoma numbers changed the maximum pressure pulsation magnitude, but no discernible differences were seen. In conclusion, the turbine showed no noticeable effects at rated operation with varying Thoma numbers under cavitation-prone situations. Further off-design investigations can be conducted based on the present methodology and compared accurately with the rated condition results.
데이터베이스 기반 프란시스 수차 러너 두께 설계 및 수치해석적 연구
노민수(Min-Su Roh),모하메드 아부 사져(Mohammad Abu Shahzer),김진혁(Jin-Hyuk Kim) 한국에너지학회 2024 에너지공학 Vol.33 No.1
본 연구에서는 30MW급 비속도 170급 고효율 프란시스 수차를 설계하기 위하여 데이터베이스 기반으로 러너 두께를 설계하고 수치해석적 연구를 통해 수력학적 성능 및 내부유동 특성 분석을 수행하였다. 러너 블레이드 두께 데이터베이스는 비속도 150, 210 및 270급 모델의 데이터를 정규화하여 구축되었으며 보간법을 적용하여 전 비속도 구간의 두께 분포 데이터를 획득하였다. 두께 분포는 허브, 중간 및 쉬라우드 스팬에서 러너 입구부터 출구까지의 정보로 구성된다. 이후 프란시스 수차의 수력학적 성능 및 내부 유동장 내 유동 특성의 정밀 분석을 위해 Reynolds-averaged Navier-Stokes(RANS) 방정식 기반의 수치해석을 수행하였다. 격자 의존성 시험 중 하나인 Grid Convergence Index(GCI) 기법을 시행함으로써 최적의 격자계를 선정하였고 이를 통해 수치해석의 정확성과 경제성을 확보하였다. 수치해석 결과, 수력학적 효율 93.63% 및 출력 30.71MW로 데이터베이스 기반 설계 방법을 사용하여 높은 수력학적 성능으로 작동하는 프란시스 수차 형상을 도출할 수 있음을 확인하였다. 내부 유동장 분석 결과, 러너 자오면 내 유동이 다소 쉬라우드 스팬에 집중되었으나 비교적 균일한 속도 성분이 분포하였으며, 러너 입출구 영역의 경우 유동 박리 등과 같은 불안정한 유동 특성이 관찰되지 않았다. 또한 러너 내부 유동 영역에서 유동 흐름을 방해하는 차폐 현상(Blockage effect) 등이 관찰되지 않았다. 러너 후단에 위치하는 드래프트 튜브의 유동장을 분석한 결과 내부 유선 분포 및 압력 분포가 안정적이므로 본 연구에서 제안된 데이터베이스 기반 비속도 170급 프란시스 수차의 러너 블레이드 두께 설계 방법에 대한 타당성을 입증하였다. 해당 연구 결과는 추후 다른 비속도 구간을 설계함에 활용될 수 있다. In this study, a high-efficiency Francis turbine was designed using a database-driven approach for the runner thickness of a prototype Francis turbine with a specific speed in the 170-class. Numerical analysis was carried out to investigate the hydraulic performance and internal flow characteristics of the turbine. The runner blade thickness database was constructed by normalizing data from models with specific speeds of 150, 210, and 270-classes. The thickness distribution data was obtained through interpolation and encompasses information from the runner inlet to the outlet at the hub, mid, and shroud spans. Subsequently, Reynolds-averaged Navier-Stokes (RANS) equations were employed in numerical simulations to accurately analyze the hydraulic performance and characteristics of the internal flow field of the Francis turbine. The Grid Convergence Index (GCI) method, utilized as a grid independence test, was used to select the optimal grid system, ensuring both the accuracy and cost effectiveness of the numerical analysis. The numerical results confirmed the feasibility of designing a Francis turbine operating at an efficiency of 93.63% and an output of 30.71MW. The internal flow analysis revealed that the runner exhibited a uniform velocity component across all span regions, without any observed unstable flow characteristics, such as flow separation at the runner inlet and outlet areas. Additionally, there was no blockage effect disrupting the flow within the runner, and uniform flow characteristics were confirmed throughout all spans. The analysis of the flow field in the draft tube downstream of the runner indicated a stable flow distribution and pressure profiles, thereby establishing the reliability of the database-driven approach for designing the runner thickness of the Francis turbine with a specific speed in the 170-class, as utilized in this study. The findings of this research can be applied in the future design of turbines across different specific speed ranges.