정성원(Sung-Won Chung),김동건(Dong-Keon Kim),공상호(Sang-Ho Gong) 한국기계가공학회 2011 한국기계가공학회지 Vol.10 No.5
This study was carried out to evaluate the structural stability of hybrid type fan heater. The evaluation of structural safety of hybrid fan heater was conducted by using Ansys Workbench and CFX-11 under the design condition. The hybrid fan heater was operated by heat transfer for heat source supplied from electric heater and combustion gas. According to result of structural analysis, the maximum equivalent stress of hybrid fan heater was 150㎫ when the temperature of heat transfer fluids was 150℃. It was found that the hybrid fan was structurally safe because the value of maximum equivalent stress was smaller than that of yield stress of the material.