RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      검색결과 좁혀 보기

      선택해제

      오늘 본 자료

      • 오늘 본 자료가 없습니다.
      더보기
      • 무료
      • 기관 내 무료
      • 유료
      • SCOPUS

        Stability of stochastic neutral neural networks with delays

        Xiaoqi Sun,Ling Zhang Techno-Press 2024 Advances in computational design Vol.9 No.2

        In this paper, we proposed a new class of stochastic neutral neural networks with uncertain and deterministic coefficients. Made the Sigmund activation and Lipschitz activation functions less conditional. The Lyapnov-Krasovskii functional is constructed. The linear matrix inequality (LMI) is constructed using Schur's lemma, and new criteria for the global asymptotic stability and global asymptotic robust stability of neural networks are obtained. Furthermore, we have verified that the method is effective and feasible through numerical examples.

      • KCI등재

        Construction of graphene/AuNPs based amperometric immunosensor for detecting bladder cancer biomarker apolipoprotein A1

        Jing Yang,Wang Xingyuan,Zhou Tingting,Wei Liangjun,Guo Meiling,Liu Yanan,Sun Xiaoqi,Wang Yanjie 한국탄소학회 2024 Carbon Letters Vol.34 No.3

        This paper presents the construction and characterization of an amperometric immunosensor based on the graphene/gold nanoparticles (AuNPs/GO) nanocomposite for the detection of the bladder cancer biomarker, apolipoprotein A1 (Apo-A1). The morphological analysis of the AuNPs/GO nanocomposite demonstrated an almost spherical shape of AuNPs and the successful coverage of their surface by graphene oxide. An increased G peak and decreased D peak after the association of AuNPs with GO, implied a reduction in graphene defects. The X-ray photoelectron spectroscopy (XPS) indicated a significant decrease in the quantity of oxygen-containing functional groups in the AuNPs/GO nanocomposite, as compared to the original GO. Furthermore, the developed sensor demonstrated commendable sensitivity and selectivity, with a wide linear range for Apo-A1 detection. Importantly, the immunosensor exhibited remarkable stability over a period of 14 days, signifying its potential for practical applications.

      • KCI등재

        Feasibility of Free-Breathing, Non-ECG-Gated, Black-Blood Cine Magnetic Resonance Images With Multitasking in Measuring Left Ventricular Function Indices

        Peng Pengfei,Yue Xun,Tang Lu,Wu Xi,Deng Qiao,Wu Tao,Cai Lei,Liu Qi,Xu Jian,Huang Xiaoqi,Chen Yucheng,Diao Kaiyue,Sun Jiayu 대한영상의학회 2023 Korean Journal of Radiology Vol.24 No.12

        Objective: To clinically validate the feasibility and accuracy of cine images acquired through the multitasking method, with no electrocardiogram gating and free-breathing, in measuring left ventricular (LV) function indices by comparing them with those acquired through the balanced steady-state free precession (bSSFP) method, with multiple breath-holds and electrocardiogram gating. Materials and Methods: Forty-three healthy volunteers (female:male, 30:13; mean age, 23.1 ± 2.3 years) and 36 patients requiring an assessment of LV function for various clinical indications (female:male, 22:14; 57.8 ± 11.3 years) were enrolled in this prospective study. Each participant underwent cardiac magnetic resonance imaging (MRI) using the multiple breath-hold bSSFP method and free-breathing multitasking method. LV function parameters were measured for both MRI methods. Image quality was assessed through subjective image quality scores (1 to 5) and calculation of the contrast-to-noise ratio (CNR) between the myocardium and blood pool. Differences between the two MRI methods were analyzed using the Bland–Altman plot, paired t-test, or Wilcoxon signed-rank test, as appropriate. Results: LV ejection fraction (LVEF) was not significantly different between the two MRI methods (P = 0.222 in healthy volunteers and P = 0.343 in patients). LV end-diastolic mass was slightly overestimated with multitasking in both healthy volunteers (multitasking vs. bSSFP, 60.5 ± 10.7 g vs. 58.0 ± 10.4 g, respectively; P < 0.001) and patients (69.4 ± 18.1 g vs. 66.8 ± 18.0 g, respectively; P = 0.003). Acceptable and comparable image quality was achieved for both MRI methods (multitasking vs. bSSFP, 4.5 ± 0.7 vs. 4.6 ± 0.6, respectively; P = 0.203). The CNR between the myocardium and blood pool showed no significant differences between the two MRI methods (18.89 ± 6.65 vs. 18.19 ± 5.83, respectively; P = 0.480). Conclusion: Multitasking-derived cine images obtained without electrocardiogram gating and breath-holding achieved similar image quality and accurate quantification of LVEF in healthy volunteers and patients.

      연관 검색어 추천

      이 검색어로 많이 본 자료

      활용도 높은 자료

      해외이동버튼