http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
함종화,윤춘경,구원석,김형철,신현범,Ham Jong-Hwa,Yoon Chun G.,Koo Won-Seok,Kim Hyung-Chul,Shin Hyum-Bhum 한국농공학회 2005 한국농공학회논문집 Vol.47 No.5
The field scale experiment was performed to examine the effect of physical design parameters on the constructed wetland performance and recommend the feasible design of constructed wetland in Korean polder areas. Four sets (each set of 0.85 ha) of wetland (0.8 ha) and pond (0.08 ha) systems were used. Two different wetland systems, a wetland-pond system and a pond-wetland system, were studied to examine the effect of wetland and pond configuration. And two different length-to-width ratios were used, 2: 1 and 0.8: 1, to examine the effect of aspect ratio. A pond-wetland system was more preferable than a wetland-pond system, and also requires a smaller area than a wetland-pond system or a wetland system to reduce T-P. There was no difference in effluent concentration between the 2:1 system and the 0.8:1 system. Although the linear velocity of the 2:1 aspect was higher than the 0.8:1 aspect, resuspension was not a factor in this study due to a very low linear velocity. From this study and other literature review, it was found that design method of paddy rice field could be applied and expanded to the design of constructed wetland in Korea. Further investigation for the detailed design parameters of constructed wetland needs be continued for design method of paddy rice to be applied in full scale.
자유수면형 인공습지에 의한 저농도 고유량의 하천수질개선 효과 분석
함종화,윤춘경,구원석,김형철,신현범,Ham, Jong-Hwa,Yoon, Chun G.,Koo, Won-Seck,Kim, Hyung-Chul,Shin, Hyum-Bhum 한국농공학회 2005 한국농공학회논문집 Vol.47 No.1
Wetland systems are widely accepted natural water purification systems around the world in nonpoint sources pollution control. Constructed wetlands have become a popular technology for treating contaminated surface and wastewater. In this study, the field experiment to reduce nonpoint source pollution loadings from polluted stream waters using wetland system was performed from June 2002 to March 2004, including winter performance using four newly constructed wetlands. The Dangjin stream water flowing into Seokmun estuarine lake was pumped into wetlands, and inflow and hydraulic residence time of the system was $500m^{3}{\~}1500m^{3}/day\;and\;2{\~}5$ days respectively. After 3 years operation plant-coverage was about $80~90\%$ from zero at initial stage even with no plantation. Average water quality of the influent in growing season was BOD_{5}\;3.96mg/L$, TSS 22.98 mg/L, T-N 3.29 mg/L, T-P 0.30 mg/L. The average removal rate of four wetlands for $BOD_{5},\;TSS,\;T-N\;and\;T-P$ in growing season was $24\%$, $62\%$, $54\%$, and $51\%$, respectively. And average water quality of the influent in winter season was $BOD_{5}$ 4.92 mg/L, TSS 12.47 mg/L, T-N 5.54 mg/L, and T-P 0.32 mg/L, respectively. The average removal rate of four wetlands for them was $-21\%$. $23\%$, $33\%$, and $53\%$, respectively. The reason of higher BOD_{5} effluent concentration in winter season might be that low temperature restrained microorganism activity and a organic body from the withered plant and algae was flown out. Except the result of $BOD_{5}$, the effectiveness of water quality improvement in winter season was satisfactory for treating polluted stream waters, and $BOD_{5}$ variation was within the range of background concentration. Performance of the experimental system was compared with existing data base (NADB), and it was within the range of general system performance. Overall, the wetland system was found to be satisfactory for NPS control such as improvement of polluted stream water.