The Power Analysis and Its Control of Two-phase Orthogonal Power Supply for the Continuous Casting
Fujun Ma,An Luo,Qiaopo Xiong 대한전기학회 2015 Journal of Electrical Engineering & Technology Vol.10 No.3
In order to improve the quality of the billet continuous casting, a two-phase orthogonal power supply (TPOPS) for electromagnetic stirrer is researched, which is composed of three-phase PWM rectifier and three-leg inverter. According to the power analysis of system, the ripple of dc-link voltage is analyzed and its analytical expression is derived. In order to improve the performance of electromagnetic stirring, an integrated control method with feedforward control is proposed for PWM rectifier to suppress the fluctuations of dc-link voltage and provide a stable dc source for inverter. According to the simplified equivalent model, a composite current control method is proposed for inverter. This proposed method can combine the merits of feedforward control with feedback control to effectively improve the dynamic output performance of TPOPS. Finally, a 300kVA prototype of TPOPS is developed, and the results have verified the analysis and control method.
The Power Analysis and Its Control of Two-phase Orthogonal Power Supply for the Continuous Casting
Ma, Fujun,Luo, An,Xiong, Qiaopo The Korean Institute of Electrical Engineers 2015 Journal of Electrical Engineering & Technology Vol.10 No.3
In order to improve the quality of the billet continuous casting, a two-phase orthogonal power supply (TPOPS) for electromagnetic stirrer is researched, which is composed of three-phase PWM rectifier and three-leg inverter. According to the power analysis of system, the ripple of dc-link voltage is analyzed and its analytical expression is derived. In order to improve the performance of electromagnetic stirring, an integrated control method with feedforward control is proposed for PWM rectifier to suppress the fluctuations of dc-link voltage and provide a stable dc source for inverter. According to the simplified equivalent model, a composite current control method is proposed for inverter. This proposed method can combine the merits of feedforward control with feedback control to effectively improve the dynamic output performance of TPOPS. Finally, a 300kVA prototype of TPOPS is developed, and the results have verified the analysis and control method.
Ma Luo,Sheng Peng,Guang Yang,Letao Lin,Ligong Lu,Jiawen Chen,Fujun Zhang,Fei Gao 대한초음파의학회 2023 ULTRASONOGRAPHY Vol.42 No.1
Purpose: The aim of this study was to compare the effectiveness and outcomes of percutaneous ablation guided by ultrasonography (US) and computed tomography (CT) in colorectal liver oligometastases (CLOM). Methods: This study included patients with CLOM treated with percutaneous ablation from January 2008 to January 2021 in this observational study. Only lesions visualized on both CT and US images were further analyzed according to whether patients’ initial ablation treatments utilized US guidance or CT guidance. The Kaplan-Meier method was used to estimate local tumor progression (LTP)–free survival after propensity score matching (PSM). The LTP-free survival and treatment-related outcomes were compared between these two groups. Results: PSM identified 116 patients from each group, with 269 and 238 lesions in the USguided and CT-guided groups, respectively. US-guided ablation had a shorter average procedure time and lower cost than CT-guided ablation (27.54±12.06 minutes vs. 32.70±13.88 minutes, P=0.003; $2,175.13±618.17 vs. $2,455.49±710.25, P=0.002). For patients >60 years of age, the cumulative LTP rate at 1 year was lower in the US-guided group than in the CT-guided group (17.8% vs. 25.1%, P=0.038). For patients with perivascular liver lesions, the cumulative LTP rate at 1 year was lower in the US-guided group (14.4% vs. 28.2%, P=0.040). Conclusion: For patients whose age is >60 years or who have perivascular liver lesions, USguided ablation is better than CT-guided ablation, with a shorter treatment time and lower costs when both ablation methods are feasible for patients.
The Development of High-Current Power Supply System for Electrolytic Copper Foil
Luo, An,Ma, Fujun,Xiong, Qiaopo,He, Zhixing The Korean Institute of Power Electronics 2015 JOURNAL OF POWER ELECTRONICS Vol.15 No.2
A 6.5 V/50 kA high-frequency switching power supply (HSPS) system composed of 10 power modules is developed to meet the requirements of copper-foil electrolysis. The power module is composed of a two-leg pulse width modulation (PWM) rectifier and a DC/DC converter. The DC/DC converter adopts two full-wave rectifiers in parallel to enhance the output. For the two-leg PWM rectifier, the ripple of the DC-link voltage is derived. A composite control method with a ripple filter is then proposed to effectively improve the performance of the rectifier. To meet the process demand of copper-foil electrolysis, the virtual impedance-based current-sharing control method with load current full feedforward is proposed for n-parallel DC/DC converters. The roles of load current feedforward and virtual impedance are analyzed, and the current-sharing control model of the HSPS system is derived. Virtual impedance is used to adjust the current-sharing impedance without changing the equivalent output impedance, which can effectively reduce current-sharing errors. Finally, simulation and experimental results verify the structure and control method.
The Development of High-Current Power Supply System for Electrolytic Copper Foil
An Luo,Fujun Ma,Qiaopo Xiong,Zhixing He 전력전자학회 2015 JOURNAL OF POWER ELECTRONICS Vol.15 No.2
A 6.5 V/50 kA high-frequency switching power supply (HSPS) system composed of 10 power modules is developed to meet the requirements of copper-foil electrolysis. The power module is composed of a two-leg pulse width modulation (PWM) rectifier and a DC/DC converter. The DC/DC converter adopts two full-wave rectifiers in parallel to enhance the output. For the two-leg PWM rectifier, the ripple of the DC-link voltage is derived. A composite control method with a ripple filter is then proposed to effectively improve the performance of the rectifier. To meet the process demand of copper-foil electrolysis, the virtual impedance-based current-sharing control method with load current full feedforward is proposed for n-parallel DC/DC converters. The roles of load current feedforward and virtual impedance are analyzed, and the current-sharing control model of the HSPS system is derived. Virtual impedance is used to adjust the current-sharing impedance without changing the equivalent output impedance, which can effectively reduce current-sharing errors. Finally, simulation and experimental results verify the structure and control method.
Chau, MinhThuyen,Luo, An,Shuai, Zhikang,Ma, Fujun,Xie, Ning,Chau, VanBao The Korean Institute of Power Electronics 2012 JOURNAL OF POWER ELECTRONICS Vol.12 No.5
This paper analyses the mathematical model and control strategies of a Hybrid Active Power Filter with Injection Circuit (IHAPF). The control strategy based on the load harmonic current detection is selected. A novel control method for a IHAPF, which is based on the analyzed control mathematical model, is proposed. It consists of two closed-control loops. The upper closed-control loop consists of a single fuzzy logic controller and the IHAPF model, while the lower closed-control loop is composed of an Adaptive Network based Fuzzy Inference System (ANFIS) controller, a Neural Generalized Predictive (NGP) regulator and the IHAPF model. The purpose of the lower closed-control loop is to improve the performance of the upper closed-control loop. When compared to other control methods, the simulation and experimental results show that the proposed control method has the advantages of a shorter response time, good online control and very effective harmonics reduction.
MinhThuyen Chau,An Luo,Zhikang Shuai,Fujun Ma,Ning Xie,VanBao Chau 전력전자학회 2012 JOURNAL OF POWER ELECTRONICS Vol.12 No.5
This paper analyses the mathematical model and control strategies of a Hybrid Active Power Filter with Injection Circuit (IHAPF). The control strategy based on the load harmonic current detection is selected. A novel control method for a IHAPF, which is based on the analyzed control mathematical model, is proposed. It consists of two closed-control loops. The upper closed-control loop consists of a single fuzzy logic controller and the IHAPF model, while the lower closed-control loop is composed of an Adaptive Network based Fuzzy Inference System (ANFIS) controller, a Neural Generalized Predictive (NGP) regulator and the IHAPF model. The purpose of the lower closed-control loop is to improve the performance of the upper closedcontrol loop. When compared to other control methods, the simulation and experimental results show that the proposed control method has the advantages of a shorter response time, good online control and very effective harmonics reduction.