http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
( Toshikazu Tanaka ),( Yoshihito Suda ),( Tomoyuki Kamenaga ),( Akira Saito ),( Takaaki Fujishiro ),( Koji Okamoto ),( Takafumi Hiranaka ) 대한슬관절학회 2022 대한슬관절학회지 Vol.34 No.-
Background: This study aims to assess the influence of intramedullary rods on the implantation positions of femoral components using Microplasty instrumentation in Oxford unicompartmental knee arthroplasty. We hypothesized that femoral components can be laterally implanted incorrectly when using intramedullary rods. Methods: This prospective study included all 45 consecutive patients (53 knees) who underwent Oxford unicompartmental knee arthroplasty surgery for anteromedial osteoarthritis or spontaneous osteonecrosis of the knee at our hospital during the study period. A custom-made toolset comprising a triangular caliper and circular trial bearings was used to evaluate the distance between the bearing and the vertical wall of the tibia implant (wall-bearing space) using the caliper at 90° flexion both with and without intramedullary rods. Results: The wall-bearing space was significantly larger when the intramedullary rod was used than when intramedullary rod was not used (1.8 ± 1.1 mm versus 3.4 ± 1.2 mm, P < 0.001). The mean difference of wall-bearing space with and without intramedullary rod was 1.6 ± 0.7 mm. Conclusions: Femoral components can be laterally implanted incorrectly by an average of 1.6 mm when using intramedullary rods. The wall-bearing space should be evaluated using trial components, and if the relationship is improper, it should be corrected before keel slot preparation.
Yoshikawa Ryo,Hiranaka Takafumi,Okamoto Koji,Fujishiro Takaaki,Hida Yuichi,Kamenaga Tomoyuki,Sakai Yoshitada 대한정형외과학회 2020 Clinics in Orthopedic Surgery Vol.12 No.2
Background: Tibial fracture after cementless Oxford unicompartmental knee arthroplasty (OUKA) is a rare but serious complication. It is reported more frequently in Asian countries. The aim of this retrospective study was to assess the morphological characteristics of the tibia by using a simple novel measurement method in patients with tibial fractures after OUKA. Methods: Six knees (all women) with tibial fractures after cementless OUKA (fracture group) and 150 knees without an obvious complication after cementless OUKA (control group) were examined retrospectively at our institution between January 2016 and April 2017. We drew a medial eminence line (ME line) defined as a line extending from the tip of the medial intercondylar eminence parallel to the tibial axis. The ME line was classified into two types (intramedullary type [type I] and extramedullary type [type E]), and the proportion of each type was compared between fracture patients and controls. Results: In the fracture group, there were four (66.7%) type E cases and two (33.3%) type I cases; in the control group, there were 18 (12%) type E cases and 132 (88%) type I cases. Fisher exact tests showed that the proportion of type E was higher in the fracture group than in the control group (p < 0.01). Conclusions: Measurement of the ME line can be recommended as a useful method to assess the risk of postoperative fracture after cementless OUKA.
Takafumi Hiranaka,Toshikazu Tanaka,Kenjiro Okimura,Takaaki Fujishiro,Rika Shigemoto,Shotaro Araki,Ryo Okada,Ryohei Nako,Tomoyuki Kamenaga,Koji Okamoto 대한정형외과학회 2021 Clinics in Orthopedic Surgery Vol.13 No.1
In Oxford unicompartmental knee arthroplasty, the relationship between the mobile bearing and the vertical wall of the tibial tray is important in preventing bearing dislocation. Separation of the bearing from the vertical wall can cause spinning of the bearing with an increased risk of subsequent dislocation. We report on intraoperative adjustment of the tibial tray performed to prevent the bearing from spinning. After tibial and femoral bone cutting and adjustment of the flexion and extension gap, the trial bearing is inserted and the bearing-vertical wall distance is evaluated before the preparation using the tibial template and bearing trial. In the case of separation, it can be resolved by medialization with or without rotational adjustment. The technique is useful and can be easily performed, it is therefore recommendable for all cases of Oxford mobile-bearing unicompartmental arthroplasty.