http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
Electrodermal Activity at Palms according to Pressure Stimuli applied to the Scapula
Kim, Jae-Hyung,Park, Gun-Cheol,Baik, Sung-Wan,Jeon, Gye-Rok Korea Multimedia Society 2016 멀티미디어학회논문지 Vol.19 No.7
The system for measuring the electrodermal activity (EDA) signal occurring at the sweet glands in the human body was implemented in this study. The EDA measurement system (EDAMS) consisted of an algometer and the bio-potential measurement system (BPMS). Three experiments were performed using EDAMS. First, the linearity of the output voltage corresponding to the pressure being applied to an algometer was evaluated. The linearity of output voltage according to the pressure was 0.956. Second, the amplitude and the latency of the EDA signal at the left palm was obtained while applying the pressure stimuli to the left and right scapula. The latency of EDA signal was shorter whereas the amplitude of EDA signal was higher when the pressure applied was applied to the left scapula. Third, the amplitude and latency of the EDA was measured at left and right palm while increasing the pressure stimuli to the left scapula. The latency of EDA signal at left and right palm was decreased according to the intensity of pressure stimulus applied to the left scapula. However, the latency of the EDA signals did not show the linearity with respect to the pressure stimuli.
Kim, Jae-Hyung,Hwang, Young-Jun,Kim, Gun-Ho,Shin, Beum-Joo,Kim, Yong-Jin,Lee, Eun-Joo,Jeon, Gye-Rok The Korean Sensors Society 2017 센서학회지 Vol.26 No.5
An early detection of infiltration in veins is essential to minimize the injuries caused during infusion therapy, which is one of the most important tasks for nurses in clinical settings. We report that bioelectrical impedance analysis is useful in the early detection of infiltration at puncture sites. When infiltration was intentionally induced in the vein of a rabbit's ear, impedance parameters showed significant difference before and after infiltration. In particular, the relative resistance at 20 kHz in the vein of rabbit's ear reduced largely at infiltration, decreased slowly, and then stayed at a constant value. This indicates that the vein in the ear of the rabbit is small, and hence the infiltrated intravenous (IV) solution no longer accumulates after 3 minutes of infiltration. However, when infiltration was induced in the vein of a human's forearm, the relative resistance at 20 kHz decreased gradually over time. In the $R-X_c$ graph, the positions in infiltration induced in the rabbit's ear rapidly shifted before and after infiltration whereas the positions in infiltration induced in the human's forearm changed gradually during infiltration. Our findings suggest that bioelectrical impedance analysis is an effective method to detect the infiltration early in a noninvasive and quantitative manners.
Yoo, Chan-Uk,Kim, Jae-Hyung,Kim, Gun-Ho,Hwang, Young-Jun,Jeon, Gye-Rok,Baik, Seong-Wan The Korean Sensors Society 2017 센서학회지 Vol.26 No.5
Indicators to quantitatively evaluate the body function may help to optimize the effectiveness of rehabilitation therapy for stroke patients. In this study, we analyzed the body composition in the paretic and nonparetic regions of stroke patients with hemiplegia caused by cerebral hemorrhage (7 cases) and cerebral infarction (13 cases) using multifrequency bioelectrical impedance. Specifically, we considered fat mass (FM), fat-free mass (FFM), FFMI index (FFMI), FM/FFM relation, body cell mass (BCM), basal metabolic rate (BMR), and BMR/FFM relation to evaluate the bodily function in the paretic and nonparetic regions. These values showed considerable differences according to grades determined by the stroke causes and the paralysis status. In the paretic regions, the FFM, FFMI, BCM, and BMR were low and the FM was high. In contrast, the nonparetic regions showed a high FFM and low FM. Furthermore, the paretic and nonparetic regions of all patients suitably fit a linear relation (slope: 22.17 kcal/day/kg) between BMR and FFM. Therefore, bio-electrical impedance measurements can be very useful to quantitatively assess paretic and nonparetic regions in hemiplegic stroke patients.