RISS 학술연구정보서비스

검색
다국어 입력

http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.

변환된 중국어를 복사하여 사용하시면 됩니다.

예시)
  • 中文 을 입력하시려면 zhongwen을 입력하시고 space를누르시면됩니다.
  • 北京 을 입력하시려면 beijing을 입력하시고 space를 누르시면 됩니다.
닫기
    인기검색어 순위 펼치기

    RISS 인기검색어

      검색결과 좁혀 보기

      선택해제
      • 좁혀본 항목 보기순서

        • 원문유무
        • 원문제공처
        • 등재정보
        • 학술지명
        • 주제분류
        • 발행연도
        • 작성언어
        • 저자
          펼치기

      오늘 본 자료

      • 오늘 본 자료가 없습니다.
      더보기
      • 무료
      • 기관 내 무료
      • 유료
      • KCI등재

        Use of Portable Global Positioning System (GPS) Devices in Exposure Analysis for Time-location Measurement

        이기영,Diana Cassady,김정윤,Kiran Putti,Deborah H. Bennett,Irva Hertz-Picciotto 한국환경보건학회 2009 한국환경보건학회지 Vol.35 No.6

        Exposure analysis is a critical component of determining the health impact of pollutants. Global positioning systems (GPS) could be useful in developing time-location information for use in exposure analysis. This study compares four low cost GPS receivers with data logging capability (Garmin 60, Garmin Forerunner 201, GeoStats GeoLogger and Skytrx minitracker MT4100) in terms of accuracy, precision, and ease of use. The accuracy of the devices was determined at two known National Geodetic Survey points. The coordinates logged by the devices were compared when the devices were carried while walking and driving. The Garmin 60 showed better accuracy and precision than the GeoLogger when they were placed at the geodetic points. The Forerunner and Skytrx did not record when they were kept stationary. When the subject wore the devices while walking, the location of the devices differed by about 8 m on average between any two device combinations involving the four devices. The distance between the coordinates logged by the devices decreased when the devices were carried with their antennas facing the sky. All the devices showed similar routes when they were used in a car. All the devices except the Forerunner had satisfactory signal reception when they were worn and when they were carried in the car. The GeoLogger is less comfortable for the subject because of specific wearing requirements. This evaluation found that the Garmin 60 and the Skytrx may be useful in personal exposure analysis studies to record time-location data.

      • KCI우수등재

        Use of Portable Global Positioning System (GPS) Devices in Exposure Analysis for Time-location Measurement

        Lee, Ki-Young,Kim, Joung-Yoon,Putti, Kiran,Bennett, Deborah H.,Cassady, Diana,Hertz-Picciotto, Irva Korean Society of Environmental Health 2009 한국환경보건학회지 Vol.35 No.6

        Exposure analysis is a critical component of determining the health impact of pollutants. Global positioning systems (GPS) could be useful in developing time-location information for use in exposure analysis. This study compares four low cost GPS receivers with data logging capability (Garmin 60, Garmin Forerunner 201, GeoStats GeoLogger and Skytrx minitracker MT4100) in terms of accuracy, precision, and ease of use. The accuracy of the devices was determined at two known National Geodetic Survey points. The coordinates logged by the devices were compared when the devices were carried while walking and driving. The Garmin 60 showed better accuracy and precision than the GeoLogger when they were placed at the geodetic points. The Forerunner and Skytrx did not record when they were kept stationary. When the subject wore the devices while walking, the location of the devices differed by about 8 m on average between any two device combinations involving the four devices. The distance between the coordinates logged by the devices decreased when the devices were carried with their antennas facing the sky. All the devices showed similar routes when they were used in a car. All the devices except the Forerunner had satisfactory signal reception when they were worn and when they were carried in the car. The GeoLogger is less comfortable for the subject because of specific wearing requirements. This evaluation found that the Garmin 60 and the Skytrx may be useful in personal exposure analysis studies to record time-location data.

      • Development of Time-location Weighted Spatial Measures Using Global Positioning System Data

        한대권,이기영,Jongyun Kim,Deborah H. Bennett,Diana Cassady,Irva Hertz-Picciotto 환경독성보건학회 2013 환경독성보건학회지 Vol.28 No.-

        Objectives Despite increasing availability of global positioning system (GPS), no research has been conducted to analyze GPS data for exposure opportunities associated with time at indoor and outdoor microenvironments. We developed location-based and time-weighted spatial measures that incorporate indoor and outdoor time-location data collected by GPS. Methods Time-location data were drawn from 38 female subjects in California who wore a GPS device for seven days. Ambient standard deviational ellipse was determined based on outdoor locations and time duration, while indoor time weighted standard deviational ellipse (SDE) was developed to incorporate indoor and outdoor times and locations data into the ellipse measure. Results Our findings indicated that there was considerable difference in the sizes of exposure potential measures when indoor time was taken into consideration, and that they were associated with day type (weekday/weekend) and employment status. Conclusions This study provides evidence that time-location weighted measure may provide better accuracy in assessing exposure opportunities at different microenvironments. The use of GPS likely improves the geographical details and accuracy of time-location data, and further development of such location-time weighted spatial measure is encouraged. Keywords Global positioning system, Indoor time-location weighted spatial measure,Time-location data

      • Development of Time-location Weighted Spatial Measures Using Global Positioning System Data

        Daikwon Han,Kiyoung Lee,Jongyun Kim,Deborah H. Bennett,Diana Cassady,Irva Hertz-Picciotto 환경독성보건학회 2013 환경독성보건학회지 Vol.28 No.-

        Objectives Despite increasing availability of global positioning system (GPS), no research has been conducted to analyze GPS data for exposure opportunities associated with time at indoor and outdoor microenvironments. We developed location-based and time-weighted spatial measures that incorporate indoor and outdoor time-location data collected by GPS. Methods Time-location data were drawn from 38 female subjects in California who wore a GPS device for seven days. Ambient standard deviational ellipse was determined based on outdoor locations and time duration, while indoor time weighted standard deviational ellipse (SDE) was developed to incorporate indoor and outdoor times and locations data into the ellipse measure. Results Our findings indicated that there was considerable difference in the sizes of exposure potential measures when indoor time was taken into consideration, and that they were associated with day type (weekday/weekend) and employment status. Conclusions This study provides evidence that time-location weighted measure may provide better accuracy in assessing exposure opportunities at different microenvironments. The use of GPS likely improves the geographical details and accuracy of time-location data, and further development of such location-time weighted spatial measure is encouraged.

      • Development of Time-location Weighted Spatial Measures Using Global Positioning System Data

        Han, Daikwon,Lee, Kiyoung,Kim, Jongyun,Bennett, Deborah H.,Cassady, Diana,Hertz-Picciotto, Irva The Korean Society of Environmental Toxicology 2013 환경독성보건학회지 Vol.28 No.-

        Objectives Despite increasing availability of global positioning system (GPS), no research has been conducted to analyze GPS data for exposure opportunities associated with time at indoor and outdoor microenvironments. We developed location-based and time-weighted spatial measures that incorporate indoor and outdoor time-location data collected by GPS. Methods Time-location data were drawn from 38 female subjects in California who wore a GPS device for seven days. Ambient standard deviational ellipse was determined based on outdoor locations and time duration, while indoor time weighted standard deviational ellipse (SDE) was developed to incorporate indoor and outdoor times and locations data into the ellipse measure. Results Our findings indicated that there was considerable difference in the sizes of exposure potential measures when indoor time was taken into consideration, and that they were associated with day type (weekday/weekend) and employment status. Conclusions This study provides evidence that time-location weighted measure may provide better accuracy in assessing exposure opportunities at different microenvironments. The use of GPS likely improves the geographical details and accuracy of time-location data, and further development of such location-time weighted spatial measure is encouraged.

      • KCI등재

        Moderate Aortic Stenosis in Patients With Heart Failure

        Vien T. Truong,John Ernst,Akhil Pallerla,Amitesh Verma,Cheryl Bartone,Cassady Palmer,Eugene S. Chung 대한심장학회 2022 Korean Circulation Journal Vol.52 No.12

        Background and Objectives: Moderate aortic stenosis (AS) confers a surprisingly adverse prognosis, approaching that of severe AS. The objective of this study was to describe the clinical course of patients with moderate AS with evidence of concomitant heart failure manifesting as elevated brain natriuretic peptide (BNP) levels. Methods: This is a single-center, retrospective cohort study of 332 patients with elevated BNP. 165 patients with moderate AS were compared with 167 controls with none-mild AS. The Median follow-up duration was 3.85 years. The primary outcome was a composite endpoint of all-cause hospitalizations and all-cause mortality. Results: BNP levels were 530 and 515 pg/mL in the study and the control groups, respectively. Moderate AS had significantly higher rates of primary composite endpoint in both univariate analysis (hazard ratio [HR], 1.50; 95% confidence interval [CI], 1.14–1.97; p=0.004) and adjusted analysis (HR, 1.45; 95% CI, 1.05–2.01; p=0.02). Moderate AS had 1.41 (95% CI, 1.18–1.69; p<0.001) times more all-cause hospitalization per patient-year of follow-up compared to controls in the univariate model. After adjustment for significant covariates, moderate AS remained an independent predictor of all-cause hospitalizations (incidence rate ratio [IRR], 1.45; 95% CI, 1.18–1.79; p=0.005). Furthermore, moderate AS was significantly associated with higher all-cause hospitalization rates in both heart failure with reduced ejection fraction (IRR, 1.33; 95% CI, 1.02–1.75; p=0.038) and heart failure with preserved ejection fraction [IRR], 1.31; 95% CI, 1.03–1.67; p=0.026). Conclusions: Moderate AS in conjunction with elevated BNP portends a significantly worse prognosis than those without moderate AS and should be followed closely.

      연관 검색어 추천

      이 검색어로 많이 본 자료

      활용도 높은 자료

      해외이동버튼