사각형 2유체 밀폐공간에서의 자연대류에 관한 연구 : 액체 대류고 분율의 변화에 관한여
이재순 건국대학교 1990 學術誌 Vol.34 No.2
Natural convection heat transfer has been conducted in the enclosure which contains two fluids, gas and liquid in which has a heat generating body. The results of thin studs are summarized as follows; 1) The heat transfer quantity through outer calls by the convection in the liquid lone is greater than that in the air zone, and the strength of convection in the liquid clone dominates the heat transfer through the outer calls. The heat transfer quantity through the outer side wall in the liquid zone becomes a major portion of the total heat transfer quantity. 2) The liquid convection height percentage (Fh) has a great influence on the convection strength of liquid clone. 3) For the strength of convection in the liquid lone, the decrease of Fh by the increase of Fc, is more effective to the decrease of Fh by the increase of Fa. When Fc is increased, a well developed secondary flow cell is found at the zone near bottom wall.