http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
주영호,조광환,이건명,Ju, Young-Ho,Jo, Gwang-Hwan,Lee, Gun-Myung 대한기계학회 1997 大韓機械學會論文集A Vol.21 No.9
A method by which the system parameter matrices can be estimated from measured time data of excitation force and acceleration has been studied. The acceleration data are integrated numerically to obtain the velocities and displacements, and the systm parameters are estimated from these data by solving equations of motion. The characteristics of the method have been investigated through its application to simulated data of 1 DOF and 2 DOF systems and experimental data measured from a simple structure. It was found that the method is very sensitive to measurement noise and the accuracy of the estimated parameters can be improved by averaging the repeatedly measured data and removing the noise. One of the main advantages of the parameter estimation method is that no a priori information about the system under test is required. The method can be easily extended to non-linear parameter estimation.
광자선 소조사면 선량측정을 위한 microDiamond 검출기의 유용성 고찰
이창열,김우철,김헌정,지영훈,김금배,이상훈,민철기,조광환,신동오,김성훈,허현도,Lee, Chang Yeol,Kim, Woo Chul,Kim, Hun Jeong,Ji, Young Hoon,Kim, Kum Bae,Lee, Sang Hoon,Min, Chul Kee,Jo, Gwang Hwan,Shin, Dong Oh,Kim, Seong Hoon,Huh, Hyun 한국의학물리학회 2014 의학물리 Vol.25 No.4
The dosimetry of very small fields is challenging for several reasons including a lack of lateral electronic equilibrium, large dose gradients, and the size of detector in respect to the field size. The objective of this work was to evaluate the suitability of a new commercial synthetic diamond detector, namely, the PTW 60019 microDiamond, for the small field dosimetry in cyberknife photon beams of 6 different collimator size (from 5 mm to 30 mm). Measurements included dose linearity, dose rate dependence, output factors (OF), percentage depth doses (PDD) and off center ratio (OCR). The results were compared to those of pinpoint ionization chamber, diamond detector, microLion liquid Ionization chamber and diode detector. The dose linearity results for the microDiamond detector showed good linearly proportional to dose. The microDiamond detector showed little dose rate dependency throughout the range of 100~600 MU/min, while microLion liquid Ionization chamber showed a significant discrepancy of approximately 5.8%. The OF measured with microDiamond detector agreed within 3.8% with those measured with diode. PDD curves measured with silicon diode and diamond detector agreed well for all the field sizes. In particular, slightly sharper penumbras are obtained by the microDiamond detector, indicating a good spatial resolution. The results obtained confirm that the new PTW 60019 microDiamond detector is suitable candidate for application in small radiation fields dosimetry. 소조사면을 이용하는 방사선치료기법들은 소조사면내의 측면 전자 비평형, 급격한 선량 변화, 그리고 조사면 크기에 대한 검출기의 기하학적 크기 영향으로 정확한 선량의 평가가 어렵다. 본 연구의 목적은 사이버나이프의 6개의 조사면(5 mm~30 mm)에 대해서 소조사면 선량측정용으로 새롭게 출시되어 상업적으로 이용되고 있는 마이크로다이아몬드(PTW 60019 microDiamond) 검출기의 유용성을 평가하고자 한다. 이를 위해 선량선형성, 선량률의존성, 출력선량계수, 깊이선량백분율 및 축바깥선량비 등의 선량측정인자를 측정하였고, 0.015 cc 부피의 이온전리함(PTW 31014 PinPoint chamber), 다이아몬드 검출기(PTW 60003 diamond), 액체이온함(PTW 31018 microLion), 그리고 다이오드 검출기(PTW 60008 diode)의 측정 결과와 비교 및 평가를 하였다. 그 결과 마이크로다이아몬드 검출기는 선량선형성이 우수하며, 선량률의존성이 적게 나타났다. 또한 사이버나이프 소조사면 측정용으로 상업적으로 권고되고 있는 다이오드 검출기와의 선량측정인자 측정값 3.8%의 차이를 보였다. 또한 깊이선량백분율도 다이오드 검출기의 결과와 유사한 결과를 얻었다. 마이크로다이아몬드 검출기는 유효체적이 작으므로 반음영이 작게 평가되었으며, 다른 검출기들보다도 공간분해능이 높은 것으로 생각된다. 연구 결과 마이크로다이아몬드 검출기는 조직등가물질로 이루어져 있으며, 작은 유효체적으로 광자선 소조사면선량측정 검출기로서 매우 유용한 것으로 판단된다.