http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
정아영(A-Yeong Jeong),김재수(Jae-Soo Kim) 한국소음진동공학회 2014 한국소음진동공학회 논문집 Vol.24 No.11
The shooting noise caused by shooting training, which has strength and impacts, is becoming a serious damage to the residents around the shooting range and, consequently, the number of civil appeals against the shooting noise is on the constant increase. For this reason, the military examines the effects of the shooting noise at the stage of design in constructing a shooting range and tries to build a soundproof shooting range to minimize civil appeals. However, the lack of research and data concerning propagation and attenuation, both of which characterize the shooting noise from within a soundproof shooting range, even makes it so difficult to design a soundproof shooting range in constructing it. So this study used an acoustic simulation in a soundproof shooting range to identify acoustic and propagation characteristics within the shooting range and, on this basis, predicted the noise level at an exit of the soundproof shooting range. As a result, if the form and specifications of a soundproof shooting range were decided on at the stage of design, it was possible to use a simulation to design a soundproof shooting range with optimized acoustic performance and, on this basis, to predict a sound pressure level at an exit of the soundproof shooting range. On the basis of these data, it is probably possible to determine the degree of the effects of the shooting noise on the villages around a shooting range and the extent of damage to it and to minimize civil appeals against the shooting noise and resolve the issues of compensation and agreement with ease. This study is expected to provide useful data for designing and constructing a similar soundproof shooting range.
비금속관 설비관통부의 슬리브 종류에 따른 내화성능 비교
정아영 ( Jeong A-yeong ),최홍범 ( Choi Hong-beom ),박진오 ( Park Jin-o ),이형도 ( Lee Hyung-do ) 한국건축시공학회 2023 한국건축시공학회 학술발표대회 논문집 Vol.23 No.1
In this study, we aimed to identify changes in fire resistance according to the type of sleeves used for pipe penetrations and to examine their accreditation of fire resistance performance and use them as basic data. The test results of fire resistance according to the type of sleeve used in non-metallic pipe facilities showed that the temperature on the support side was higher for sleeves with higher thermal conductivity. For the temperature on the surface of the pipes, in the case of galvanized steel plates, steel pipes, and structures without sleeves, the highest temperature was observed after the expansion of the firestop material for 46 to 53 minutes and then decreased. PVC sleeves showed a steady increase in temperature until 53 minutes, after which the temperature did not increase further. In addition, for non-metallic pipes, the effect of the type of sleeve on fire resistance is considered to be insignificant because the lower part (heating direction of the furnace) under the support structure is cut off to block the heat during the two-hour fire resistance test.