http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
전현(Hyun Jeon),가동훈(Donghun Ka),안태영(Taeyoung Ahn) 전력전자학회 2006 전력전자학술대회 논문집 Vol.- No.-
This paper proposed synchronous rectifier in forward converter including resonance reset did not get efficiency drive waveform for that is existent dead time period. Therefore, proposed synchronous rectifier of new way accordingly to solve problem by happened drive circuit. Confirmed usefulness and practicality by drive circuit that compose experiment circuit and propose through experiment result. Input voltage of experiment circuit are 380V, and output voltage are 12V, and maximum output current is 20A, and maximum output was 100W.
젊은 여성의 몸통 근육 활성도 분석을 통한 목발 길이 측정 방법의 효율성 비교
전현 ( Hyun Jeon ),오덕원 ( Duck-won Oh ) 대한물리의학회 2020 대한물리의학회지 Vol.15 No.1
PURPOSE: This study compared the activities of the trunk muscles during crutch walking to determine which of the crutch length measurements is most beneficial. METHODS: Twenty young women volunteered to participate in this study. After adjusting crutch length, the participants performed a three-point walking with nondominant leg limited in weight bearing. This study used six crutch length measurements: (1) Height-40.6cm, (2) Height´.77, (3) Olecranon-to-finger length, (4) Axillary-toheel length, (5) Arm-span length-40.6cm, and (6) Arm-span length´.77. The EMG activities of the internal oblique (IO), rectus abdominis (RA), multifidus (MF), and erector spinae (ES), muscles on the weight bearing side were monitored using wireless surface EMG. RESULTS: The EMG activities of the RA and ES appeared to be significantly different among the crutch length measurements (p<.05). The post-hoc test showed that the ‘Arm-span length-40.6cm’ was significantly greater in the RA activity when compared to the ‘Height´.77’ and ‘Axillary-to-heel length’ measurements, and in the ES activity when compared to ‘Height´.77’ measurements. Furthermore, IO/RA and MF/ES ratios showed significant differences among the crutch length measurements (p<.05). In the post-hoc test, significant difference was observed between ‘Olecranon-to-finger length’ and ‘Arm-span length-40.6cm’ for the IO/RA ratio, and between ‘Height´.77’ and ‘Olecranon-to-finger length’ and between ‘Height´.77’ and ‘Arm-span length-40.6cm’ measurement for the MF/ES ratio. CONCLUSION: These findings suggest that the ‘Height´.77’ measurement is relatively advantageous to optimize the activities of trunk muscles during the crutch walking, and allow simple measurements of the crutch length.
1.5V 60A급 VRM의 인덕터 손실 분석에 관한 연구
전현(hyun Jeon),이달우(darl-woo Lee),안태영(tae-young Ahn),최광보(gwang-bo Choi) 전력전자학회 2005 전력전자학술대회 논문집 Vol.- No.-
In this paper, to report the experimental results the core losses of VRM inductor. The VRM, that has a output voltage 1.5V, output current 60A, maximum power of 90W. Experimental results verify, the VRM has a almost same data of fast transient response, a efficiency test with high flux and ferrite inductor. A maximum power conversion efficiency of the experimental VRM was measured at 92% within 0.2% load regulation.