http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
김명호(M.-H. Kim),최정열(J.-Y. Choi),김귀순(K.S. Kim),이기수(G.S. Lee),김유일(Y.I. Kim),임진식(J.S. Lim) 한국전산유체공학회 2001 한국전산유체공학회 학술대회논문집 Vol.2001 No.-
An accelerating flow field through a compressor cascade is studied numerically by unsteady computational simulation. The two-dimensional Navier-Stokes equations for compressible flow is used for the study of unsteady high incidence angle flow, with preconditioning scheme to cover the wide range of Mach number and k-ωmodel for the turbulent viscous flow analysis. A DCA(double circular arc) compressor blade is accelerated artificially in this study to understand the unsteady effect by comparing the present results with the existing steady-state experimental and computational results. Also, the accelerating flow field during the starting phase of gas turbine is studied with actual experimental data for the understanding of flow field and performance characteristics at off-design condition.
플라이휠 저장 에너지를 이용한 무순단 전압보상 기능을 갖는 UPS
이기수(K.S. Lee),김중원(J.W. Kim),변우열(W.Y. Byeon),노의철(E.C. Nho),김인동(I.D. Kim),전태원(T.W. Chun),김흥근(H.G. Kim) 전력전자학회 2004 전력전자학술대회 논문집 Vol.- No.-
This paper deals with the operation of a flywheel energy storage UPS. The ups has good features such as long life-time, improved efficiency, no environment problems, reduced size and space, and low maintenance cost compared with the conventional UPS using battery. The operating principle of the UPS is analysed in each mode including charging, voltage compensation, discharging, and voltage unbalance compensation. Especially, the tracking characteristic of the disturbed phase of the source voltage after outage is analysed. The usefulness of the operation is proved through simulations.
플라이휠 저장 에너지를 이용한 다이나믹 UPS 동작 특성 분석
이기수(K.S. Lee),김중원(J.W. Kim),변우열(W.Y. Byeon),노의철(E.C. Nho),김인동(I.D. Kim),전태원(T.W. Chun),김흥근(H.G. Kim) 한국조명·전기설비학회 2004 한국조명·전기설비학회 학술대회논문집 Vol.2004 No.5월
This paper describes a dynamic UPS system with flywheel energy storage element. There are three operating modes of charging, voltage compensation, and UPS. The operating principle of each mode is analyzed and simulated. The simulation results show the validity of the operation of the proposed scheme.
3상 다이나믹 UPS 성능 시험을 위한 Sag-Swell 발생기
김중원(J.W. Kim),이기수(K.S. Lee),변우열(W.Y. Byun),노의철(E.C. Nho),김인동(I.D. Kim),전태원(T.W. Chun),김흥근(H.G. Kim) 한국조명·전기설비학회 2004 한국조명·전기설비학회 학술대회논문집 Vol.2004 No.5월
This Paper describes a new 3 phase Sag-Swell generator for the test of custom power devices such as UPS, DVR, DSTATCOM, SSTS, etc. The proposed scheme has good features of simple structure, high reliability, wide range of sag and swell variation. It can also generate voltage outage. The control scheme for the generation is simple. The operation principle of the proposed scheme is described and verified through simulations.
Myrinet 환경에서 예조건화 Navier-Stokes 코드의 병렬처리 성능
김명호(M.-H. Kim),이기수(G.S. Lee),최정열(J.-Y. Choi),김귀순(K.S. Kim),김성룡(S.-L. Kim),정인석(I.-S. Jeung) 한국전산유체공학회 2001 한국전산유체공학회 학술대회논문집 Vol.2001 No.-
Parallel performance of a Myrinet based PC-cluster was tested and compared with a conventional Fast-Ethernet system. A preconditioned Navier-Stokes code was parallelized with domain decomposition technique, and used for the parallel performance test. Speed-up ratio was examined as a major performance parameter depending on the number of processor and the network topology. As was expected, Myrinet system shows a superior parallel performance to the Fast-Ethernet system even with a single network adpater for a dual processor SMP machine. A test for the dependency on problem size also shows that network communication speed is a crucial factor for parallelized computational fluid dynamics analysis and the Myrinet system is a plausible candidate for high performance parallel computing system.