http://chineseinput.net/에서 pinyin(병음)방식으로 중국어를 변환할 수 있습니다.
변환된 중국어를 복사하여 사용하시면 됩니다.
우유미,송종관,조규만,이현종,홍태훈,현창택,구교진,Woo, Yu-Mi,Song, Jong-Kwan,Cho, Kyu-Man,Lee, Hyung-Jong,Hong, Tae-Hoon,Hyun, Chang-Taek,Koo, Kyo-Jin 한국건설관리학회 2007 건설관리 : 한국건설관리학회 학회지 Vol.8 No.4
Recently, in the korean construction industry, the importance of cost management in the building design process has been grown up institutional systems and policies for the cost management of design stages are however weakness. Traditionally, the range of cost management has been limited to the construction stages, and due to inefficiency of the infrastructure such as standards and building cost data for cost management. It has trouble to perform the cost management in building design process. This study intends to derive key influence factors for raising efficiency of cost management. With questionnaire surveys to professionals, we analyze a current situations and the influence of obstacle factors on cost management. Finally, the key influence factors are induced, based on the result of the analysis on influence the obstacle factors. 최근 건설 사업에서 시공이전단계인 설계단계 공사비관리의 중요성이 대두되고 있지만, 설계단계 공사비관리를 위한 제도적 장치나 기술수준은 외국에 비해 매우 낙후되어 있다. 전통적으로 건설 사업에서 공사비관리는 시공단계에 국한되어, 설계단계 공사비관리를 위한 기본 틀과 분류 표준, 공사비 데이터 등 인프라가 부족하여 설계단계 공사비관리 업무를 수행하는데 있어 한계가 있다. 따라서 본 연구에서는 국내 설계단계에서 공사비관리가 효율적으로 수행되기 위해 관리되어야 할 주요 영향요인을 도출하고자 하였다. 설계실무자를 대상으로 설문조사를 통해 설계단계 공사비관리 현황과 문제점을 분석하였고, 설계단계 공사비관리 저해항목에 대해 공사비관리 업무에 미치는 영향도를 조사하였다. 요인분석을 통해 5개의 설계단계 공사비관리 주요 영향요인을 도출하여 향후 설계단계 공사비관리 지원도구 및 제도적 기반 구축에 기여할 수 있도록 하였다.
Flashlight-Induced High-Performance Stretchable Cu conductoers
Yu Mi Woo(우유미),Ui Yeon Nam(남의연),Yeon Uk kim(김연욱),Jae Hun Yang(양재훈),Pyeong An Kim(김평안),Jae Jun Lee(이재준),Seoung Jun Lee(이승준) 대한기계학회 2021 대한기계학회 춘추학술대회 Vol.2021 No.11
Herein, we report a novel stretchable Cu conductors with significant conductivity and elasticity, which was allowed by the flash-induced multiscale interface interactions between Cu and a polymer. Microscale randomly wrinkled Cu was demonstrated on an elastomer by irradiating single pulse of millisecond flashlight, enabling stretchability of Cu conductor to exceeding 20% in all directions. Simultaneously, the enhanced adhesion force of the nanoscale interlocked interface between the Cu nanoparticles and the elastomeric substrate increased the reliability and elasticity of Cu. Finally, the fabricated crumpled Cu conductor exhibited outstanding electrode conductivity of 37 kS cm<SUP>-1</SUP> despite severe stress caused by the motion of human wrist, which was successfully utilized for wireless near-filed communication system.
서용칠,우유미,이승훈,Seo, Yong-Chil,Woo, Yu-mi,Lee, Seung-Hoon 한국건축시공학회 2010 한국건축시공학회지 Vol.10 No.2
VE분석 결과물은 다양한 분야의 실무자들이 그들의 경험과 지식을 활용하여 생산한 실현가능성 높은 제안들이다. 따라서 과거 유사한 사업에서 수행되었던 VE분석 결과물은 조정 혹은 재가공 등의 과정을 거쳐 새로운 프로젝트에 효과적으로 활용될 수 있다. 이를 위해서는 과거 수행되었던 VE분석에 의해 생산된 중간결과물인 기능과 아이디어, 최종결과물인 제안내용을 일정한 체계에 따라 축적할 필요가 있다. 따라서 본 연구에서는 VE 과거 실적사례 수집을 위한 데이터 구성 체계를 수립하고, 데이터 추출 및 조정 과정을 제시하였다. VE 절차에 따라 데이터를 '대상', '기능', '아이디어', '제안' 카테고리로 분류하여 각 카테고리의 특성 및 수행방식에 따라 데이터 구성원칙을 수립하였다. 또한 본 연구에서는 VE 제안서 샘플사례를 바탕으로 각각의 카테고리의 데이터 추출 및 조정 방법을 제시하였다. 본 연구에서 제시한 VE 데이터 구축 방안에 따라 VE 실적사례 데이터베이스를 구축한다면, VE분석 각 단계에서 과거 VE사례를 유용하게 활용할 수 있으며, VE분석의 생산성을 크게 향상시킬 수 있을 것으로 기대된다. The results of VE (Value Engineering) analyses are highly feasible proposals that are produced by utilizing the experience and knowledge of professionals from a variety of fields. As such, the results of past similar projects can be useful in new projects. On this basis, it is vital to accumulate the historical data of the results on VE analyses performed at every stage, which are functions, ideas, and proposals. In this research, a data formational system for collecting this historic data was established by categorizing 'Item,' 'Function,' 'Idea,' and 'Proposal' according to VE process, and the data retrieval and the adjusting process were proposed. If the historic data of these are accumulated using the suggested method, it is expected to be useful at the stage of VE process.
이승훈,우유미,이성락,구교진,현창택,홍태훈,Lee, Seung-Hoon,Woo, Yu-Mi,Lee, Sung-Rak,Koo, Kyo-Jin,Hyun, Chang-Taek,Hong, Tae-Hoon 한국건설관리학회 2006 건설관리 : 한국건설관리학회 학회지 Vol.7 No.6
사회기반시설의 노후화에 따라 시설물 유지관리에 관한 관심이 증대되고 있으며, 이에 따라 다양한 사회기반시설에 대한 LCC분석 연구가 수행되고 있다. 특히 기계설비가 다수 포함된 기반시설에서는 시설물의 건설비와 더불어 보수/교체비, 에너지비 등 유지관리비용이 높은 비중을 차지하고 있다. 이에 본 연구에서는 하수처리장의 슬러지 수집기 선정에 있어 정량적 요소와 정성적 요소를 모두 고려하는 LCC 분석 모델을 개발하고, 사례적용을 통하여 최적대안을 선정하고자 한다. 문헌고찰과 분석대상 하수처리장의 슬러지 수집기에 대한 공사비와 유지관리 및 보수/교체 이력자료를 바탕으로 비용항목을 도출한다. LCC분석을 위한 가정사항 설정 후, 각 항목별 실적자료와 장비납품업체의 정보를 활용하여 경제성 평가결과를 도출하고, 할인율과 초기투자비 및 유지관리비의 비용변동범위에 따른 민감도분석을 실시한다. 설계자, 자재공급업체 및 시공전문가의 면담을 통하여 유지관리 편의성, 조달 용이성, 슬러지 수집 성능, 침전물제거 효율도, 환경친화성 등 슬러지 수집기 선정을 위한 기술적 사회적 영향인자를 파악한다. 분석된 기술적 사회적 요인과 LCC 분석결과인 경제성에 대하여 각 항목별 쌍별비교를 통하여 항목별 가중치를 설정하고 전문가 평가를 통하여 종합적인 최적안을 선정한다. This study focused on developing Life Cycle Cost(LCC) analysis model for selecting sludge collectors in wastewater treatment system and applying the model to a case study. Cost items are examined through literature review and historical data of a facility. Analysis period, discount rate, energy cost escalation ratio are assumed to reasonable level. Monetary evaluation is performed using historical data and estimations from vendors. Sensitive analysis is executed using Monte Carlo Simulation for assumed factors. Interviews with operators, vendors, constructors, managers are conducted to define factors which indicates ease of maintenance, ease of delivery, technical performance, efficiency, environmental friendship. Factors are representing technical and social factors. Results from LCC analysis and qualitative analysis are evaluate together with Weighted Matrix Evaluation Methods for optimum alternative of sludge collectors.
Ui Yeon Nam(남의연),Yu Mi Woo(우유미),Yeon Uk Kim(김연욱),Jae Hun Yang(양재훈),Pyeong An Kim(김평안),Jae Jun Lee(이재준),Jung Hwan Park(박정환) 대한기계학회 2021 대한기계학회 춘추학술대회 Vol.2021 No.11
Herein, a outstanding performance Cu nanowires with sheet resistance of 17Ω sq<SUP>-1</SUP> and transmittance of 88% was fabricated by flash-induced plasmonic nanowelding process. The high-intensity flashlight (in the region of visible wavelength) significantly enhanced plasmonic welding of Cu NW intersections without any oxidation. Simultaneously, near-infrared (NIR) spectrum of flash light interlocked the interface between polyethylene terephthalate substrate and Cu NWs. To investigate the adhesion enhacement of interlocked Cu NWs, we conducted a quantitative peel test. the measured NW interfacial fracture force increased by 208% compared to that of a pristine Cu NW electrode. To demonstrate versatile uses of flash-induced Cu NW conductors, transparent resistive memory devices and touch screen panel were successfully fabricated on plastics by employing the flash-welded excellent performance Cu NW network.