시뮬레이션을 통한 전면형 이중외피의 하절기 열환경 개선 연구
趙秀(Cho Soo),임혜진(Im Hye-Jin),성욱주(Sung Uk-Ju),박정환(Park Jeong-Hwan) 대한건축학회 2012 대한건축학회논문집 Vol.28 No.5
The purpose of this study was to analyze the thermal environments of a multistory facade in the summer through simulation. The optimal simulation was conducted by outside glass specifications and outlet opening rate of a double skin to change. As a result, intermediate space temperature of double skin was lowered up to approximately about 4.8 ℃ and airflow through the inlet and outlet openings of the difference was reduced to a maximum of about 0.1 ㎥/s. Therefore, airflow through a double skin is thouht to be able to be release smoothly without problem.
임혜진(Hye-Jin Im),조수(Soo Cho),성욱주(Uk-Ju Sung),임상훈(Sang-Hun Lim),한찬훈(Chan-Hun Haan) 대한설비공학회 2012 설비공학 논문집 Vol.24 No.2
In this study, to present the data in the internal thermal condition of Double skin facade were measured internal temperature and inlet and outlet openings wind speed of double skin facade. Measurements were similar to temperatures in the upper double skin facade. Especially in summer, temperature stratification is through to be unfulfilled seamlessly despite inlet and outlet openings open. Double skin facade inlet and outlet openings of the air flow rate was slower outlet openings of the air flow rate than inlet openings of the air flow rate.